Loading...
HomeMy WebLinkAboutLIFT STATION NO. 39 FORCEMAIN REPLACEMENTMAYOR: COUNCIL: LIFT ST'ATION NO. 39 FORCEMAIN -REPLACEMENT Louis R. Rigby AT —LARGE A: AT —LARGE B: POSITION 9: POSITION 2: POSITION 3: POSITION 4: POSITION 5: POSITION 6: John P. Zemanek Dottie Kaminski Mike Mosteit Chuck Engelken Daryl Leonard Tommy Moser Jay Martin Mike Clausen CITY MANAGER: Corby D. Alexander wills iff !M JUNE 2014 5€h opt � _ s,!¢ �vxi:: •: r13CKQ " rz �t 1+ � Hollow Tree vn A r �.1 wf r :Ba Shone Dr Pir BILif -St ce ��r r �I of V 'ptviy CI116 �r � o Fairfield S - W lndleaf Ur j 64 Meadowlawn Ave:_ `?�y. F ones X % , ' o I— Forest +eve � CJ„ o r _ SteagTctve Aft,_. Seagra LU Oakdale Ave In P Sha{:j+lativr7 AVt i l h� it d { aua .'kL iris x OA,' 1'1 `'Plla `CAI. �A104-00-00 5_Shady;Ln I If ki,11 PROJECT g LOCATION ` VICINITY MAP KEY MAP: 580 Q, U 7:7 PIE71 11200 Broadway Street Offices West, Suite 2332 Peariand, Texas 77584 Office: (832) 456-4700 Fax: (832) 456-4701 Drawing List 1 :Ba Shone Dr Pir BILif -St ce ��r r �I of V 'ptviy CI116 �r � o Fairfield S - W lndleaf Ur j 64 Meadowlawn Ave:_ `?�y. F ones X % , ' o I— Forest +eve � CJ„ o r _ SteagTctve Aft,_. Seagra LU Oakdale Ave In P Sha{:j+lativr7 AVt i l h� it d { aua .'kL iris x OA,' 1'1 `'Plla `CAI. �A104-00-00 5_Shady;Ln I If ki,11 PROJECT g LOCATION ` VICINITY MAP KEY MAP: 580 Q, U 7:7 PIE71 11200 Broadway Street Offices West, Suite 2332 Peariand, Texas 77584 Office: (832) 456-4700 Fax: (832) 456-4701 Drawing List 1 COVER SHEET 2 GENERAL NOTES 3-5 PLAN & PROFILE SHEETS 6 CONNECTION DETAILS 7 STANDARD DETAILS 8 STANDARD DETAILS 9 EXPRESS REVIEW SHEET THE SEAL THAT ORIGINALLY APPEARED ON THIS OOCIIMENT WAS AUTHORIZED BY WI TEXAS NO: 97372 ON 6 12 2014 ALTERATION OF A SEALED DOCUMENT WRHOUT PROPER NOTIFICATION OF THE RESPONSIBLE ENGINEER IS AN OFFENSE UNDER THE TEXAS ENGINEERING PRACTICE ACT. Freese and Nichols, Inc. Texas Registered Engineering Firm F-2144 This Record Drawing is o combination of the sealed engineering contract drawings for this project, modified by information furnished by the contractor reflecting changes in the Project made during construction. The original sealed drawings ore on file at the offices of FREESE AND NICHOLS, INC. 4055 INTERNATIONAL PLAZA, SUITE 200 FORT WORTH, TEXAS 76109-4895 (817) 735-7300 RECORD DRAWINGS PREPARED ON: 1/7/2015 LPT13493 GENERAL NOTES: (THE FOLLOWING NOTES APPLY TO ALL SHEETS OF THESE CONTRACT DOCUMENTS AS IF THEY WERE WRITTEN IN THEIR ENTIRETY ON EACH SHEET) 1. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND BONDS PRIOR TO START OF WORK. 2. ALL CONSTRUCTION IS TO BE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS AND BE SUBJECT TO INSPECTION BY THE CITY OF LA PORTE AND THE ENGINEER. 3. THE CONTRACTOR SHALL USE EXISTING RIGHT-OF-WAYS OR EASEMENTS FOR ACCESS TO THE JOB SITE. 4. PUBLIC AND PRIVATE UTILITY LINES AND CUSTOMER SERVICE LINES MAY EXIST THAT ARE NOT SHOWN ON THE CONSTRUCTION DRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO LOCATE, MAINTAIN AND PROTECT THE INTEGRITY OF THESE LINES. 5. CONTRACTOR SHALL NOTIFY ENGINEER IF THERE IS A CONFLICT BETWEEN THE CONTRACT DOCUMENTS AND EXISTING CONSTRUCTION BEFORE PROCEEDING WITH WORK. NO SEPARATE PAY UNLESS NOTED OTHERWISE. 6. EXISTING IMPROVEMENTS INCLUDING, BUT NOT LIMITED TO FENCES, DRIVEWAYS, SIDEWALKS, PAVEMENT, CURBS, UTILITY PIPELINES, AND DRAINAGE STRUCTURES WHICH ARE DAMAGED, REMOVED OR ALTERED TO PERMIT INSTALLATION OF THE WORK SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR TO CITY STANDARDS, AT THE CONTRACTOR'S EXPENSE, IN THE SAME LOCATION AND IN CONDITION AS GOOD AS OR BETTER THAN THEY WERE FOUND. 7. CONTRACTOR IS RESPONSIBLE FOR ALL GROUND AND SURFACE WATER CONTROL AND DEWATERING NECESSARY TO PROTECT THE PROJECT AREA IN ORDER TO PERFORM PROPOSED WORK. 8. THE CONTRACTOR SHALL NOT DISPOSE OF ANY EXCAVATED MATERIALS WITHIN AN AREA DESIGNATED AS BEING WITHIN THE 100-YEAR SPECIAL FLOOD HAZARD AREA. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FLOOD PLAIN STATUS OF ANY PROPOSED DISPOSAL SITE. DISPOSAL SITES SHALL BE APPROVED BY THE CITY, INCLUDING HAUL ROUTES. 9. CONTRACTOR SHALL MAINTAIN ADEQUATE SITE DRAINAGE TO ENSURE A DRY WORK AREA AT ALL TIMES DURING CONSTRUCTION. FINAL DETERMINATION BY CITY REPRESENTATIVE. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING REQUIRED SECURITY TO PROTECT HIS PROPERTY, EQUIPMENT, WORK IN PROGRESS AND COMPLETED WORK, AT NO ADDITIONAL COST TO THE CITY. 11. DO NOT EXCEED 75% OF MANUFACTURER'S RECOMMENDED MAXIMUM DEFLECTION FOR PIPE JOINTS, UNLESS NOTED OTHERWISE. 12. CONTRACTOR SHALL VERIFY THAT PIPING SHOWN TO BE ABANDONED OR AS ABANDONED PREVIOUSLY IS NO LONGER IN SERVICE. LINES IN SERVICE SHALL BE MAINTAINED UNTIL NO LONGER REQUIRED BY THE OWNER. LINES SHALL BE ABANDONED IN PLACE OR REMOVED AS INDICATED ON THE DRAWINGS. 13. CONTRACTOR SHALL REROUTE THE EXISTING PIPING IF REQUIRED TO AVOID THE PROPOSED STRUCTURES. THE EXISTING SYSTEM SHALL REMAIN IN PLACE AND IN SERVICE UNTIL THE PROPOSED SYSTEM IS CONSTRUCTED, ACCEPTED AND PLACED INTO SERVICE. THE CONTRACTOR SHALL PROTECT THE EXISTING SYSTEM UNTIL IT IS TAKEN OUT OF SERVICE. CONTRACTOR SHALL SUBMIT AN RFI PRIOR TO PERFORMING WORK. 14. ALL PROPOSED PENETRATIONS IN THE EXISTING WALLS SHALL BE SEALED PER TYPICAL/STANDARD DETAILS. 15. THE CONTRACTOR SHALL TAKE SPECIAL PRECAUTIONS IN THE VICINITY OF ANY OVERHEAD ELECTRIC LINES. CONTRACTOR SHALL ABIDE BY THE MOST RECENT NATIONAL ELECTRIC CODE AND ANY REQUIREMENT BY OWNER OF ELECTRIC LINES. 16. CONTROL POINTS SHOWN ON PLANS ARE INTENDED FOR CONSTRUCTION STAKING OF THIS PROJECT. ANY ADDITIONAL SURVEYING NEEDED SHALL BE SUBSIDIARY TO THE OVERALL COST OF THE PROJECT. CONTROL POINT INFORMATION IS LOCATED ON SHEET 5. 17. ALL TRENCH EXCAVATION SHALL BE IN ACCORDANCE WITH THE U.S. DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATOR'S STANDARDS. CONTRACTOR IS RESPONSIBLE FOR ALL TRENCH SAFETY. THE CONTRACTOR SHALL CONSTRUCT THE PROPOSED WORK UTILIZING A TRENCH SAFETY PLAN. 18. ALL DEMOLISHED STRUCTURES AND NON -SALVAGED EQUIPMENT, AS WELL AS EXCESS EXCAVATED SOILS, SHALL BE REMOVED AND DISPOSED OF IMMEDIATELY IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL LAWS, REGULATIONS AND OTHER 0 ~ ORDINANCES AT NO ADDITIONAL COST TO OWNER. FURNISH WRITTEN VERIFICATION m FROM THE OWNER OF THE DISPOSAL SITE AUTHORIZING THE CONTRACTOR TO a DISPOSE OF MATERIALS IS ACCEPTABLE. I ry iu) 19. EXCAVATION ADJACENT TO EXISTING UTILITIES TO REMAIN OR CROSSING UTILITIES (n SHALL BE EXCAVATED BY HAND AND IN SUCH A MANNER AS TO AVOID DAMAGE �:2 TO THE EXISTING FACILITIES. EXISTING UTILITIES SHALL BE PROPERLY SUPPORTED o WITHIN THE PROPOSED TRENCH AND BACKFILLED WITH CEMENT STABILIZED SAND otoOR FLOWABLE FILL. FN 'O N V) O 20. ANY EXISTING PIPING THAT IS AFFECTED BY NEW CONSTRUCTION OR PIPING -1 0 INSTALLATION, UNLESS DEMOLISHED AND REMOVED, SHALL BE RETURNED TO N ORIGINAL OR BETTER CONDITION AT NO ADDITIONAL COST TO THE OWNER. PIPING REPAIR SHALL INCLUDE CONSIDERATION FOR BACKFILL, ENCASEMENT, SUPPORTS, z -o RESTRAINTS, FITTINGS, VALVES, INSULATION AND ANY TYPICAL OR SPECIAL > COATINGS THAT ARE APPLIED TO THE INTERIOR AND/OR EXTERIOR OF THE PIPING o v°n AND ITS APPURTENANCES. a a n 0 o Plot Dote: 1 13/2015 10:02 AM Plot BY: fb Filename: N:\UTIL\Record Drowings\GN-ALL-NOTES. 21. CONTRACTOR SHALL MAINTAIN FLOW IN DRAINAGE DITCHES AT ALL TIMES AND PROVIDE TEMPORARY STRUCTURAL OR NON-STRUCTURAL STORM WATER PROTECTION AND POLLUTION PREVENTION MEASURES (SWPPP) THROUGHOUT THE PROJECT SITE WHERE REQUIRED. METHODS USED BY CONTRACTOR TO MAINTAIN FLOW IN DITCH AND PROVIDE SWPPP MEASURES MUST BE ACCEPTABLE TO THE CITY. 22. WHERE GRASS IS DISTURBED BY AN ACTIVITY OF THIS PROJECT, CONTRACTOR SHALL REPLACE GRASS BY HYDRO -MULCH SEEDING INCLUDING BOTH PERMANENT BERMUDA GRASS SEED AND WINTER WHEAT SEED SUCH THAT THE GRASS THAT WAS PRESENT IN PRE -CONSTRUCTION CONDITIONS IS REPLACED AND/OR RESTORED TO ITS CONDITION IN AS GOOD OR BETTER CONDITION THAN PRIOR TO CONSTRUCTION. SOD OF EQUAL TYPE TO EXISTING GRASS, SHALL BE PLACED IN DISTURBED AREAS IN RESIDENTIAL YARDS AND IN DISTURBED R.O.W. AREAS IMMEDIATELY ADJACENT TO RESIDENTIAL YARDS. 23. THRUST AT BENDS, TEES, PLUGS, OR OTHER FITTINGS SHALL BE RESISTED BY RESTRAINED MECHANICAL JOINT FITTINGS AND CONCRETE THRUST BLOCKS. MECHANICAL JOINT RESTRAINTS SHALL BE MEGA -LUG OR APPROVED EQUAL. 24. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO GUARD AGAINST DAMAGES TO PROPERTY AND INJURY TO PERSONS. THE CONTRACTOR SHALL PUT UP AND MAINTAIN WARNING LIGHTS AT NIGHT, SUITABLE BARRICADES AND OTHER DEVICES AND SIGNAGE NECESSARY TO PROTECT THE PUBLIC. ALL SUCH SIGNALS OR DEVICES SHALL COMPLY WITH THE LATEST EDITION OF THE TEXAS MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (TMUTCD). TEXAS COMMISSION ON ENVIRONMENTAL QUALITY LIFT STATIONS AND FORCE MAINS GENERAL CONSTRUCTION NOTES: 1. THIS LIFT STATION AND/OR FORCE MAIN MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY'S (TCEQ) EDWARDS AQUIFER RULES 30 TEXAS ADMINISTRATIVE CODE (TAC) §213.5(C), THE DESIGN CRITERIA FOR DOMESTIC WASTEWATER SYSTEMS 30 TAC CHAPTER 217, AND THE CITY OF LA PORTE STANDARD SPECIFICATIONS. 2. ANY MODIFICATION TO THE ACTIVITIES DESCRIBED IN THE REFERENCED LIFT STATION/FORCE MAIN SYSTEM APPLICATION FOLLOWING THE DATE OF APPROVAL MAY REQUIRE THE SUBMITTAL OF A LIFT STATION/FORCE MAIN SYSTEM APPLICATION TO MODIFY THIS APPROVAL, INCLUDING THE PAYMENT OF APPROPRIATE FEES AND ALL INFORMATION NECESSARY FOR ITS REVIEW AND APPROVAL. 3. PRIOR TO COMMENCING ANY REGULATED ACTIVITY, THE APPLICANT OR HIS AGENT MUST NOTIFY THE TCEQ HOUSTON REGIONAL OFFICE, IN WRITING, OF THE DATE ON WHICH THE REGULATED ACTIVITY WILL BEGIN. 4. IF ANY SENSITIVE FEATURES ARE DISCOVERED DURING THE WASTEWATER LINE TRENCHING ACTIVITIES, ALL REGULATED ACTIVITIES NEAR THE SENSITIVE FEATURE MUST BE SUSPENDED IMMEDIATELY. THE APPLICANT MUST IMMEDIATELY NOTIFY THE APPROPRIATE REGIONAL OFFICE OF THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY OF THE FEATURE DISCOVERY. A GEOLOGIST'S ASSESSMENT OF THE LOCATION AND EXTENT OF THE FEATURE DISCOVERED MUST BE REPORTED TO THAT REGIONAL OFFICE IN WRITING WITHIN TWO WORKING DAYS. THE APPLICANT MUST SUBMIT A PLAN FOR ENSURING THE STRUCTURAL INTEGRITY OF THE SEWER LINE OR FOR MODIFYING THE PROPOSED COLLECTION SYSTEM ALIGNMENT AROUND THE FEATURE. THE REGULATED ACTIVITIES NEAR THE SENSITIVE FEATURE MAY NOT PROCEED UNTIL THE EXECUTIVE DIRECTOR HAS REVIEWED AND APPROVED THE METHODS PROPOSED TO PROTECT THE SENSITIVE FEATURE AND THE EDWARDS AQUIFER FROM ANY POTENTIALLY ADVERSE IMPACTS TO WATER QUALITY WHILE MAINTAINING THE STRUCTURAL INTEGRITY OF THE LINE. HARRIS COUNTY TRAFFIC NOTES: 1. CONTRACTOR SHALL PROVIDE AND INSTALL TRAFFIC CONTROL DEVICES IN CONFORMANCE WITH PART VI OF TEXAS MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (TMUTCD -LATEST EDITION WITH REVISIONS) DURING CONSTRUCTION. 2. NO LANES SHALL BE BLOCKED FROM 7 A.M. TO 9 A.M. AND 4 P.M. TO 6:30 P.M. MONDAY THRU FRIDAY. 3. OFF DUTY POLICE OFFICERS/FLAGGERS ARE REQUIRED TO DIRECT TRAFFIC WHEN LANES ARE BLOCKED. 4. CONTRACTOR SHALL COVER THE EXCAVATION WITH STEEL PLATES ANCHORED PROPERLY DURING NON -WORKING HOURS AND ALLOW NORMAL TRAFFIC FLOW. IF COVERING IS NOT FEASIBLE, USE TRANTEX FR 336 EFX 36" DELINEATOR OR APPROVED EQUAL WITH SHEETING AND BASE EPDXIED TO PAVEMENT NEXT TO EXCAVATION DURING NON -WORKING HOURS. 5. APPROVED COPIES OF "TRAFFIC CONTROL PLANS" SHALL BE AVAILABLE FOR INSPECTION AT ALL TIMES. 6. IF THE CONTRACTOR CHOOSES TO USE A DIFFERENT METHOD OF TRAFFIC CONTROL PLAN DURING THE CONSTRUCTION THAN WHAT IS OUTLINED IN THE CONTRACT DRAWINGS, (S)HE SHALL BE RESPONSIBLE TO PREPARE AND SUBMIT ALTERNATE PLANS* TO TRAFFIC SECTION OF HCPID FOR APPROVAL TEN WORKING DAYS PRIOR TO IMPLEMENTATION. *THESE PLANS SHALL BE DRAWN TO SCALE ON REPRODUCIBLE MYLARS AND SEALED BY A LICENSED ENGINEER IN THE STATE OF TEXAS. PLANS WILL BECOME A PART OF THE CONTRACT DRAWINGS. 7. IF THE PROJECT IS WITHIN 400 FEET FROM A SIGNALIZED INTERSECTION, THE CONTRACTOR SHALL CONTACT HARRIS COUNTY PUBLIC INFRASTRUCTURE DEPARTMENT, SIGNAL DIVISION, AT 713-881-3210 FIVE (5) WORKING DAYS PRIOR TO THE START OF CONSTRUCTION. CENTERPOINT ENERGY FACILITIES CAUTION: UNDERGROUND GAS FACULTIES LOCATIONS OF CENTERPOINT ENERGY MAIN LINES (TO INCLUDE CENTERPOINT ENERGY, INTRASTATE PIPELINE, LLC. WHERE APPLICABLE) ARE SHOWN IN AN APPROXIMATE LOCATION ONLY. SERVICE LINES ARE USUALLY NOT SHOWN. OUR SIGNATURE ON THESE PLANS ONLY INDICATES THAT OUR FACILITIES ARE SHOWN IN APPROXIMATE LOCATION. IT DOES NOT IMPLY THAT A CONFLICT ANALYSIS HAS BEEN MADE. THE CONTRACTOR SHALL CONTACT THE UTILITY COORDINATING COMMITTEE AT (713) 223-4567 OR 1-800-669-8344 A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION TO HAVE MAIN AND SERVICE LINES FIELD LOCATED. • WHEN CENTERPOINT ENERGY PIPE LINE MARKINGS ARE NOT VISIBLE, CALL (713) 967-8037 (7:00 AM TO 4:30 PM) FOR STATUS OF LINE LOCATION REQUEST BEFORE EXCAVATION BEGINS. • WHEN EXCAVATING WITHIN EIGHTEEN INCHES (18") OF THE INDICATED LOCATION OF CENTERPOINT ENERGY FACILITIES, ALL EXCAVATION MUST BE ACCOMPLISHED USING NON -MECHANIZED EXCAVATION PROCEDURES. • WHEN CENTERPOINT ENERGY FACILITIES ARE EXPOSED, SUFFICIENT SUPPORT MUST BE PROVIDED TO THE FACILITIES TO PREVENT EXCESSIVE STRESS ON THE PIPING. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY DAMAGES CAUSED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE THESE UNDERGROUND FACILITIES. WARNING: OVERHEAD ELECTRICAL LINES OVERHEAD LINES MAY EXIST ON THE PROPERTY. THE LOCATION OF OVERHEAD LINES HAS NOT BEEN SHOWN ON THESE DRAWINGS AS THE LINES ARE CLEARLY VISIBLE, BUT YOU SHOULD LOCATE THEM PRIOR TO BEGINNING ANY CONSTRUCTION. TEXAS LAW, SECTION 752, HEALTH & SAFETY CODE FORBIDS ALL ACTIVITIES THAT OCCUR IN CLOSE PROXIMITY TO HIGH VOLTAGE LINES SPECIFICALLY: • ANY ACTIVITY WHERE PERSON OR THINGS MAY COME WITHIN SIX (6) FEET OF LIVE OVERHEAD HIGH VOLTAGE LINES; AND • OPERATING A CRANE, DERRICK, POWER SHOVEL, DRILLING RIG, PILE DRIVER, HOISTING EQUIPMENT, OR SIMILAR APPARATUS WITHIN 10 FEET OF LIVE OVERHEAD HIGH VOLTAGE LINES. PARTIES RESPONSIBLE FOR THE WORK, INCLUDING CONTRACTORS, ARE LEGALLY RESPONSIBLE FOR THE SAFETY OF CONSTRUCTION WORKERS UNDER THIS LAW. THIS LAW CARRIES BOTH CRIMINAL AND CIVIL LIABILITY. TO ARRANGE FOR LINES TO BE TURNED OFF OR REMOVED CALL CENTERPOINT ENERGY AT (713) 207-2222. AT&T TEXAS/SWBT FACILITIES 1. THE LOCATIONS OF AT&T TEXAS/SWBT FACILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION BEFORE COMMENCING WORK. HE AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY THIS FAILURE TO EXACTLY LOCATE AND PRESERVE THESE UNDERGROUND UTILITIES. 2. THE CONTRACTOR SHALL CALL 1-800-344-8377 A MINIMUM OF 48 HOURS PRIOR TO CONSTRUCTION TO HAVE UNDERGROUND LINES FIELD LOCATED. �o C t v ,Or O O w V U Ic` w- Cep Z O NC NFo Z"o �m 0 I O Ca., tP U N� � a oc0�f, to prn ''E-o•02 Jtno ¢ pa Ut V O,.0 N O Icyn M 2'U) U E C N;r n0..- 0 0 0:- c- V o. U¢U¢II � o y C C ar U p ZXn Zn o •- w ttaad� tTV TW c" 0 O~ part.=oD o'w z o v M0c O•; W,n¢ O 0 0E0LLJ �v :ENi! w •� T`" W w U E c� Wj M Hp N W p WV O �aaoE dwoon o ���0 us N n n y anry U N 00 N d O N ~ � n 3. p 3 co 3: O c pco 'ooxv � Q. Q_ F- z LiJ W U Q J n Lli x ry W Ldi z z O Q n Q aw LL.0 ry O w 0 z c) I Lit 0 n 0 z 3. WHEN EXCAVATING WITHIN EIGHTEEN INCHES (18") OF THE INDICATED LOCATION OF AT&T (n TEXAS/SWBT FACILITIES, ALL EXCAVATIONS MUST BE ACCOMPLISHED USING NON -MECHANIZED -I EXCAVATION PROCEDURES. WHEN BORING, THE CONTRACTOR SHALL EXPOSE THE AT&T TEXAS/SWBT FACILITIES. Mcy) Lo = m = 4. WHEN AT&T TEXAS/SWBT FACILITIES ARE EXPOSED, THE CONTRACTOR WILL PROVIDE SUPPORT TO M a PREVENT DAMAGE TO THE CONDUIT DUCTS OR CABLES. WHEN EXCAVATING NEAR TELEPHONE z F- n 3 POLES THE CONTRACTOR SHALL BRACE THE POLE FOR SUPPORT, o J w S2 3 N w �- 5. THE PRESENCE OR ABSENCE OF AT&T TEXAS/SWBT UNDERGROUND CONDUIT FACILITIES OR BURIED o 0 0 'o 0 I CABLE FACILITIES SHOWN ON THESE PLANS DOES NOT MEAN THAT THERE ARE NO DIRECT BURIED w o 2 J CABLES OR OTHER CABLES IN CONDUIT IN THE AREA. o ^ Z I z 0 m m 6. PLEASE CONTACT THE AT&T TEXAS DAMAGE PREVENTION MANAGER MR. ROOSEVELT LEE JR. AT (713)567-4552 OR E-MAIL HIM AT RL7259@ATT.COM, IF THERE ARE QUESTIONS ABOUT BORING - 100 c OR EXCAVATING NEAR OUR AT&T TEXAS/SWBT FACILITIES. -n ai O C O c 0 N TXDOT NOTES: O c ,,,, (n0 �o_0 -c0 1. CONTRACTOR SHALL NOTIFY TXDOT 48 HOURS (2 BUSINESS DAYS) 0 BEFORE CONSTRUCTION STARTS TO ALLOW FOR PROPER INSPECTION 0 N CN AND COORDINATION OF WORK DAYS AND TRAFFIC CONTROL PLANS. z 3 N DO NOT START CONSTRUCTION UNTIL YOU HAVE COORDINATED THE m0a CONSTRUCTION START DATE AND INSPECTION WITH TXDOT. w 0 J� ¢ 2. A COPY OF THE APPROVAL, NOTICE OF PROPOSED INSTALLATION, AND 0 N ANY APPROVED AMENDMENTS SHALL REMAIN AT THE JOB SITE AT ALL - � L_ TIMES. � Fr w o >o 3. TRAFFIC CONTROL IN UTILITY WORK ZONES SHALL CONFORM TO APPLICABLE SPECIFICATIONS TO TMUTCD, PART VI. SEQ. 2 z EXIST LIFT STATION NO. 39 O w H H � � vN r O F-df- Q� L_ O O N J H m w _ J ¢ cy, _ U W C n > a GRAVE4 CD 18" PIPE' FL -1.7 18" PIPE FL -1.3 16 STA 0+00 BEGIN PROP 6" FORCE MAIN CONNECT TO EXIST 6" LIFT STATION SEE DETAIL, SHEET 6 N=13,793,393.57 E=3,233,314.34 CUT & PLUG EXIST FM POTHOLE NORTHING 1379 340 4.213 18" PIPE EASTING 3233296.672 FL 2.5 4'-2" BELOW N.G. I GRAVEL 18" PIPE 24" PIPE FL -1.5 FL -2.0 18" PIPE FL -1.6 CCI CONTORL POINT #1 COTTON SPINDLE W/ WASHER 'CCI' Y 13793380.78 X 3233339.98 Z 6.90 (A1104-1 1-00) EXIST 6" FORCE MAIN (TO BE GROUT FILLED AND ABANDONED IN PLACE) 18" PIPE 24" PIPE /FL 2.7 / FL 3.4 GRAVEL 24" PIPE FL -2.3 WATER LINE NOTE: N N NEW 8" PVC C- INS WATER LINE TAL900LED BY DIRECTIONAL BORE 36" PIPE FL 0.4 TXDOT ROW _ —ORIO 1{ V tVV W YY� T TUV W VV VV:I � J T�V VY G G GRAVEL m APPROX. LOCATION POTHOLE: 4" GAS LINE AS SHOWN 5' X 6' BOX NORTHING 13793602.821 ON MAP F32640670 FL -2.9 EASTING: 3233282,94 AS PROVIDED BY ENTEX 4'-5" BELOW N.G. APPROX. LOCATION 2" GAS LINE AS SHOWN ON MAP F32640670 24" PIPE PROVIDED BY ENTEX FL -3.4 ADD 360 LF OF 8" PVC C900 (CERTALOK PIPE) BY DIRECTIONAL DRILL TO REPLACE A LEAKING WATER MAIN DISCOVERED DURING THE COURSE OF CONSTRUCTION. THE LOCATION OF THE NEW WL IS BETWEEN STA 2+00 AND STA 5+60. FINAL PIT LOCATIONS TO BE COORDINATED IN THE FIELD WITH CITY PERSONNEL. THE CITY WILL BE RESPONSIBLE FOR MAKING THE CONNECTIONS BACK TO THE EXISTING WATER MAIN, TESTING AND DISINFECTION. x z V) oQ << w U z O J O m J Z Q o�o w ooz�o Q� _ LD > w d O N O _rq� ¢nv>wm 4' C.L.F 36" PIPE /FL 0.5 G PROP 6" FORCE MAIN) APPROX. LOCATION 3/4'' GAS LINE AS SHOWN w d ° ON MAP F32640670 w w a_D a dC,PROVIDED BY ENTEX ° N ° r 0 J O LJi BRIDGE END. 3/8" I.R. 0 -J w TXDOT ROW � � w _ — + 0 8+�0 +p w w POTHOLE ° MAILBOX NORTHING 13793962.306 a M EXIST ATT UGT EASTING: 3233266.226 0 _j 4'-2" BELOW N.G. OLD HIGHWAY 146 APPROX. LOCATION (ASPHALT PAVEMENT) 2" GAS LINE AS SHOWN ON MAP F32640670 (TxDOT R.O.W.) PROVIDED BY ENTEX GENERAL UTILITY NOTES: 1. LOCATION OF UTILITIES SHOWN ARE APPROXIMATE. IT IS THE CONTRACTORS RESPONSIBILITY TO LOCATE ALL UTILITIES (PUBLIC AND PRIVATE) PRIOR TO COMMENCING WORK. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY DAMAGES CAUSED BY HIS FAILURE TO LOCATE AND PRESERVE THESE UTILITIES WHETHER UNDERGROUND, ABOVE GROUND OR OVERHEAD. 2. CONTRACTOR SHALL CONTACT 811 AND ALL OF THE FOLLOWING PHONE NUMBERS FOR LOCATION OF UNDERGROUND FACILITIES 72 HOURS PRIOR TO ANY EXCAVATION IN THE AREA: (281) 471-9650 (CITY OF LA PORTE PUBLIC WORKS) (281) 470-6451 (CITY OF SHOREACRES PUBLIC WORKS) 1-800-245-4545 (TEXAS ONE CALL SYSTEM) 3. ALL PIPING SHALL BE INSTALLED WITH A CONTINUOUS, INSULATED TW, THW, THWN OR HMWPE INSULATED COPPER, 10 GAUGE OR THICKER WIRE FOR PIPELINE LOCATION PURPOSES BY MEANS OF AN ELECTRONIC LINE TRACER. THE WIRE SHALL BE INSTALLED ALONG THE ENTIRE LENGTH OF PIPE. THE INSULATION COLOR SHALL MATCH THE COLOR OF THE PIPE BEING INSTALLED. SECTIONS OF WIRE SHALL BE SPLICED TOGETHER USING APPROVED SPLICE CAPS AND WATER PROOF SEALS. TWISTING THE WIRES TOGETHER IS NOT ACCEPTABLE. 0 O O � LLJ N LL RAJ zLij W U N Q 1 F, 980' 6" 0 FORCE MAN (SDR21, CERTAFLO) INSTALL BY DIRECTIONAL BORE 12 20' ^- 6" 0 FORCE MAIN 12 INSTALL BY OPEN CUT EXIST 6" FORCE MAIN 8 TO BE GROUT FILLED 8 AND ABAND-CRED71T-PLACE) 4 OF PROP FORCE MAIN 4 CST ATT UGT CUT & PLUG EXIST 6" FORCE MAINir EXIST FM (TO BE GROUT FILLED -- >���������� 0 AND ABANDONED IN LACE) - v 0 z EXIST GAS LINE EXIST GAS LINE _ Ld > —4 00. U —4 —8 —8 PROP 6" FORCE MAIN PROP 6" FORCE MAIN co co o LO PROP 6" FORCE MAIN o N o 0o (0 O� r�7 �t d�-I� �I� �n C11N� �� �tf) �d �N �� -12 4I I r I I I I cv 1 K 1 4 1 (6 1 � 1 —12 RJUMAJ "M9I9J 2 + U U 3+00 4+00 1972DI J 6+00 7+00 9+00 10+00 a- c O p 0 N O U `O !�.0 C c.coUo Z Z Nm 0 S ° p ° o= 0.. J v=io Q O� E O 0-c Ua_ la0 U O Zmu M�N ° ^Zn z w�a o d•-`om c ° �, a g um uE$a'ov `` w 0 O mv�0 N O•p L N O..8�d N a N uE 0 20' 40' 80' ti N SCALE IN FEET 0 2' 4' 8' z S VERTICAL SCALE WJ N M 1 O M N W = to 0 �V sE W I It O (N^N7 �alw Ui ^vmm v X M � � M 3 ® o m -6I CO 3 o o m 1 i o z c N = p U1 �aaw3 w C G W U Q J W X ry LL IZ- z d Q —I Q = >_ J W L- U O ry O G II n O z U) _1 SEC. 3 u 'o 0 I z U) in U I W 2 a L 0 w d N a J Z J G_D m c 00 c of o.S o Ca)N o c,, 0 Un C ' C OC 0 0 o_c f� C p7 o° O < O N >o Plot Date: 1/13/2015 10:02 AM Plot By: fb Filename: N: 0) 3 a N O I z cn I -0 a I T k- 0] a J -O I > J o H(f) C O Q 3 O N � p d- U 0) 0 o vJ � o; m o E 0 OQ m (n U - O Q w J 0 0 LJ h ~ V) LEI Lr<1 Z N J LLJ Lu U � Q 16 G U) z O x 3: APPROX. LOCATION W�i p z 7- Co F 0 4" GAS LINE AS SHOWN � ry o z Taw g o Li ON MAP F32640670 �uU O � 1- a ¢ (- PROVIDED BY ENTEX zN Q � Q a „ o � m z O v 0CN } EXIST 6 FORCE MAIN J G r x of Lil o I� J 07 (TO BE GROUT FILLED X N � o w x ry N Xcn o AND ABANDONED IN PLACE) 0 < > 10 Q — 0- 0 a- NI WN 0 IW a_O O Q ("1O a_ X _ FND. 5/8" I.R. ¢ v o a- O W " 15" X 30" PIPE x n FL 5.3 FND. 1" I.P. 15" PIPE PROP 6" FORCE MAIN J FL 6.5 in w 80 ROW FND15" PIPE — / — FND. 1" I.P. FL 6.7 FND. 1" I.P. —TXDOT ROW _ TXDOT ROW _ 5+ 1 vv W -F I I �— W G G G V G G G GRAVEL GRAVEL G � G G TRAFFIC SIGNAL POST POTHOLE GRAVEL 15" PIPE 15" PIPE POTHOLE: w \ NORTHING 13794660.549 FL 6.5 NORTHING:13795156.948 d SAN. M.H. 15" X 30" PIPE EASTING 3233231.145 FL 6.7 TOP 8.7 FL 5.6 4'-5" BELOW N.G. EASTING: 3233204.692 o UNABLE TO SIZE PIPE N FL -0.4 4'-0" BELOW N.G. "' UNABLE TO SIZE PIPE W FL -4.3 � 18" X 24" PIPE x OLD HIGHWAY 146 FL 4.1 (ASPHALT PAVEMENT) CCI CONTORL POINT #2 (TxDOT R.O.W.) POTHOLE COTTON SPINDLE W/ WASHER 'CCI' GENERAL UTILITY NOTES. NORTHING 13794465.655 Y 13794515.45 EASTING 3233241.71 X 3233326.06 3'-8" BELOW N.G. Z 9.21 0 0' LLJ F- w N 0 Iw w N a POTHOLE' > NORTHING 13795252.003 Qr EASTING 3233201.084 50' ROW Q W-0" BELOW N.G. o FND. 1" I.P. II 11 _ JTXDOT ROW If G WATER VALVE �APPROX. LOCATION TOP 4.6 4" GAS LINE AS SHOWN 18" X 24" PIPE ON MAP F32640670 FL 4.3 AS PROVIDED BY ENTEX 1. LOCATION OF UTILITIES SHOWN ARE APPROXIMATE. IT IS THE CONTRACTORS RESPONSIBILITY TO LOCATE ALL UTILITIES (PUBLIC AND PRIVATE) PRIOR TO COMMENCING WORK. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY DAMAGES CAUSED BY HIS FAILURE TO LOCATE AND PRESERVE THESE UTILITIES WHETHER UNDERGROUND, ABOVE GROUND OR OVERHEAD. 2. CONTRACTOR SHALL CONTACT 811 AND ALL OF THE FOLLOWING PHONE NUMBERS FOR LOCATION OF UNDERGROUND FACILITIES 72 HOURS PRIOR TO ANY EXCAVATION IN THE AREA: (281) 471-9650 (CITY OF LA PORTE PUBLIC WORKS) (281) 470-6451 (CITY OF SHOREACRES PUBLIC WORKS) 1-800-245-4545 (TEXAS ONE CALL SYSTEM) 3. ALL PIPING SHALL BE INSTALLED WITH A CONTINUOUS, INSULATED TW, THW, THWN OR HMWPE INSULATED COPPER, 10 GAUGE OR THICKER WIRE FOR PIPELINE LOCATION PURPOSES BY MEANS OF AN ELECTRONIC LINE TRACER. THE WIRE SHALL BE INSTALLED ALONG THE ENTIRE LENGTH OF PIPE. THE INSULATION COLOR SHALL MATCH THE COLOR OF THE PIPE BEING INSTALLED. SECTIONS OF WIRE SHALL BE SPLICED TOGETHER USING APPROVED SPLICE CAPS AND WATER PROOF SEALS. TWISTING THE WIRES TOGETHER IS NOT ACCEPTABLE. Q N LO LLJ LLJ LLJ z_N LLJ M01 1000' 6" 0 FORCE MIN (SDR21, CERTAFLO) INSTALL BY DIRECTIONAL BORE 12 12 EXIST SAN SWR MH EXIST GROUND „ FORCE MAIN UF PROP FORCE MAIN „ FOIRCF MAIN 8 L--- TO BE GROUT FILLED TO BE GROUT FILLED 8 AND ABANDONED IN LACE) AND ABANDONED IN PLACE) EXIST GAS LINE 4 ------ � EXIST GAS LINE 4 EXIST GAS LINE ---"EXIST GAS LINE — — EXIST SAN SWR 0 - 0 PROP 6" FORCE MAIN CLR PROP 6" FORCE MAIN -4 LPROP 6" FORCE MAIN -4 EXIST SAN SWR -8 -8 c0 On 0 0 00 c0 00— r 0 d to 0 — r O 7 7 Ol 0 n 0 0 N � LO �p 00 n - 1 2 4 1 r- I L6 1 �6 1 6 1 (6 1 -0 60 a;0 �0 �6o -12 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 d a N WJ N M Och N W= h dvaoE �_ N cO I o N ^ N ONV Tm N N M 3 p ® m -6 1 00 3 o o N I N p L . N ^ a a CW G LiJ U Q J W F- ry g LLJ L- U O 0 O LL J M L0 � 0 Zo D- M V)OJ a 0 9 0 20' 40' 80' N SCALE IN FEET 0 2' 4' 8' z SHEI VERTICAL SCALE mw� 1H 0 0 0 N Q V) 0 0 0 0 T- � I w a N a J z I J \ � O C] O O C .O'c ai O s U ca�N O c ,,_, O to s O U 0-0 c c O 0 a, U, Nc N d 0 N M -0 p W� G= Q O N w �I > o Plot EXIST 6" FORCE MAIN O (TO BE GROUT FILLED O cr' AND ABANDONED IN PLACE) O N °� � n ,n W d w d r N o � � r a r o o 63 _ Eo ~ W TXDOT ROW V) Lj — MOHF— N zi W— —i— — N -�Q0 23+ W — J Lu— G G G 1 G G G G X Lij GRAVEL GRAVEL m V W w D_ Q APPROX. LOCATION ' o- r a r 2" GAS LINE AS SHOWN - J 5 ON MAP F32640670 L� PROVIDED BY ENTEX FM -❑ GRAVEL STA 26+85 END PROP 6" FORCEMAIN CONNECT TO EXIST SS MH SEE DETAIL SHEET 6 N=13796059.56 E=3233164.95 PROP 6" FORCE MAIN EXIST ATT CABLE GENERAL UTILITY NOTES: OLD HIGHWAY 146 _ (ASPHALT PAVEMENT) (TxDOT R.O.W.) 1. LOCATION OF UTILITIES SHOWN ARE APPROXIMATE. IT IS THE CONTRACTORS RESPONSIBILITY TO LOCATE ALL UTILITIES (PUBLIC AND PRIVATE) PRIOR TO COMMENCING WORK. THE CONTRACTOR IS FULLY RESPONSIBLE FOR ANY DAMAGES CAUSED BY HIS FAILURE TO LOCATE AND PRESERVE THESE UTILITIES WHETHER UNDERGROUND, ABOVE GROUND OR OVERHEAD. 2. CONTRACTOR SHALL CONTACT 811 AND ALL OF THE FOLLOWING PHONE NUMBERS FOR LOCATION OF UNDERGROUND FACILITIES 72 HOURS PRIOR TO ANY EXCAVATION IN THE AREA: (281) 471-9650 (CITY OF LA PORTE PUBLIC WORKS) (281) 470-6451 (CITY OF SHOREACRES PUBLIC WORKS) 1-800-245-4545 (TEXAS ONE CALL SYSTEM) 3. ALL PIPING SHALL BE INSTALLED WITH A CONTINUOUS, INSULATED TW, THW, THWN OR HMWPE INSULATED COPPER, 10 GAUGE OR THICKER WIRE FOR PIPELINE LOCATION PURPOSES BY MEANS OF AN ELECTRONIC LINE TRACER. THE WIRE SHALL BE INSTALLED ALONG THE ENTIRE LENGTH OF PIPE. THE INSULATION COLOR SHALL MATCH THE COLOR OF THE PIPE BEING INSTALLED. SECTIONS OF WIRE SHALL BE SPLICED TOGETHER USING APPROVED SPLICE CAPS AND WATER PROOF SEALS. TWISTING THE WIRES TOGETHER IS NOT ACCEPTABLE. II• BRICK FENCE G G GRAVEL POTHOLE 10 NORTHING: 13795977.773 FASTING 3233163 571 LVX)l CoLL_ Li ) w :60' RO APPROX. LOCATION 2" GAS LINE AS SHOWN J � ON MAP F32640670 LLJ I PROVIDED BY ENTEX = SAN. M.H. TOP 10.3 � 15" W FL -8.6 v�i 15" N FL -8.6 1 i � 6" S FL -0.8 Cl so CUT & PLUG EXIST FM 4'-9" BELOW N.G. I APPROX. LOCATION ON MAP F32640670 PROVIDED BY ENTEX CCI CONTORL POINT B3 COTTON SPINDLE W/ WASHER 'CCI' Y 13796067.62 X 3233236.36 Z 10.20 CONTROL POINT INFORMATION: PROVIDED BY CIVIL CONCEPTS, INC. VERTICAL CONTROL VERTICAL CONTROL BASED ON NAVD 88 2001 ADJUSTMENT (TSARP RM 010270) RM 010270 FLOODPLAIN REFERENCE MARK NUMBER 010270 IS A BRASS DISC STAMPED 010270 IN BRIDGE OVER TAYLOR BAYOU IN KEYMAP 580P NEAR STREAM A104-00-00 ELEV. 6.61 NAVD 1988> (2001 ADJUSTMENT TSARP). HORIZONTAL CONTROL HORIZONTAL CONTROL BASED ON NAD 83, TEXAS STATE PLANE SOUTH CENTRAL ZONE (4204), SURFACE, (VRS/RTN NETWORK TIED TO THE CORS SYSTEM USING ROD1 CORS ARP, PID DJ8995) AND MAY BE CONVERTED TO GRID BY DIVIDING BY A COMBINED SCALE OF 1.00013. CCI CONTROL POINT # 1 COTTON SPINDLE W/ WASHER 'CCI' Y 13,793,380.78 X 3,233,339.98 Z 6.90 CCI CONTROL POINT #2 COTTON SPINDLE W/ WASHER 'CCI' Y 13,794,515.45 X 3,233,326.06 Z 9.21 CCI CONTROL POINT #3 COTTON SPINDLE W/ WASHER 'CCI' Y 13,796,067.62 X 3,233,236.36 Z 10.20 16 00 @ 5' 6" FORCE MAIN 670' ^6"0 ORCE MAIN (SDR21, CERT FLO) INS LL BY OPEN CUT INSTA L BY DIRECTIONAL BORE 12 EX ST SAN SWR MH 12 EXIST ROUND N O SEQ. a 0 8 0 20' 40' 80' SCALE IN FEET N 0 2' 4' 8' S VERTICAL SCALE WJ ry N II�O N iii=! WV in o n - �vdoE U d� ,p 7 to n to � ai nary �y p �-00M 3 ® ma1 0103 N S N p v -aa�3Ix 5 I z • ng I 25' 1 EXIST CHAINLINK FENCE EXIST SAN SWR e, 6 MANHOLE z O¢w p m` N iE O z Nrn o FEU EXIST LS 39 °• ° L Z EXIST INTERNAL DROP ° 3 ° ' " EXIST 6" Cl FORCE MAIN ° ° ° vi sm W _ �a z WET WELL (TO BE REMOVED) (TO BE REMOVED) E -J no 9Ui = € JE6z EXIST 6" Cl FORCE MAIN v �M�� s 6"X90' PVC (TO BE GROUT FILLED • a � o'zz AND ABANDONED IN CUT & PLUG EXIST \ PLACE) 6" FORCE MAIN 02 D N 0 �a4K w— - - - - - - - - -- - _ — --III-�-� w E u E v v o w CNz zO ow <F44 �'O V N U� LL "OI1 • '&L w 0 TO N - rwx w�zo\ / 4 6 V000 'C EXIST 6" Cl FORCE MAIN EXIST 6" Cl FORCE MAIN REMOVE PIPE AND ~ " Qa° " CUT & PLUG EXIST (TO BE GROUT FILLED AND SEAL HOLE W/(TO BE ABANDONED) I I 6 FORCE MAIN ABANDONED IN PLACE) NON-SHRINK GROUT EXIST ROW I WJ EXIST ROW PROP INTERNAL DROP �o II 1 (SEE DETAIL 2, SHEET 7) WV N g ^ �� mvaoE 5 PROP � - - - - - - - - - - - I N^ � , v TO EXIST CONNECTION XIST SSMH aw o q — — — — — — (SEE DETAIL 3, SHEET 7) max n ® O O N I m m t o —aa. 0 EXIST "X90' BEND 22' (TO E REMOVED) IF-- I Z REMOVE AND REPLACE STA 0+00 W APPROX 10 LF OF PROP 6"X90' PVC O CHAINLINK FENCE AS SOLVENT WELDED BEND LLi NECESSARY FOR W/ THRUST BLOCK I 0 CONSTRUCTION Q J W w PROP 6" PVC FORCE MAIN W z 0 O z _ CC _J � G � W Q PROP 6" PVC PROP 6"X90' PVC �` U 0 O FORCE MAIN SOLVENT WELDED BEND o W/ THRUST BLOCK Q � Z PLAN rn Q SCALE: 1 "=2' U OLD HIGHWAY 146 CONNECTION DETAIL STA 26 + 85 Q PLAN z SCALE: 1 "=5' U) 32' +/- EXIST 6"X90 BEND EXIST GROUND rn L m ON LS DISCHARGE O) 0 0 3 Ii M N Z OZ z - M 0 o f o o ow W Z Z w y a z PROP 6" DI PIPEz Z w O w FLGXPE) APPROX 4' COVER 0 o < O w o p U EXIST 6"X90• BEND ~ p rl z J EXIST 6"X90• BEND EXIST 6" Cl PIPE (TO BE REMOVED) LU (TO BE REMOVED) f(To BE REMOVED) z U] m O O NOTE: STA 0+00 .2 ci O -.- - - - - - - - - - � m ~ — - - - - - - - - - - - - - - - - PROP 6"X90' PVC oc: CID 1 . DUCTILE IRON PIPE SHALL BE EPDXY COATED AND LINED c N �' SOLVENT WELDED WITH FACTORY INSTALLED PROTECTO 401 CERAMIC EPDXY o o" In BEND W/ THRUST o N BLOCK LINING, AND SHALL BE PRESSURE CLASS 250, MINIMUM. U ov - c o 2. BYPASS CONNECTION AT LIFT STATION TO REMAIN INTACT. °'" O- PROP 6"X90' (MJ) DI 3. INSTALL TRACING WIRE STATIONS INSIDE LIFT STATION c� •�c W/ THRUST BLOCK PROP 6 PVC PIPE FENCE AND NEAR EXISTING SANITARY SEWER MANHOLE. m - 1 TRACING WIRE STATION TO BE RHINO TRIVIEW FLEX FOR SEWER WITH INTERNAL TERMINALS, OR APPROVED EQUAL. p o j � SECTION NO SEPARATE PAY ITEM. w 0 N SCALE: 1 "=2' D O E � Ld 0 CONNECTION DETAIL STA 0 +00 z V >o SHEET 6 Plot Date: 1/13/2015 10:02 AM Plot By: lb Filenome: N:\UTIL\Recorcj Drawings\UTIL—DT—CONNECTION.dwg SEO. y N O w L L 0 O 7 U O OL O O N i 0¢w �' .oWa 2 t U,1+1 p Z Eo cos 0y, (I =rn CE €a luz LI u N w� Jm2 ; O C Z 6M�N room <c • O ` ^Zh C �VZOh TRENCH WIDTH = PIPE O.D. + 24" MIN. �300ww EXISTING TO PIPE O.D. + 36" MAX. 12" TOP SOIL GROUND 7 SOD OR SEED (AS REQ EXIST SS MN UIRED) PER ° c E o ui -2 ov Nao-'CITY OF PORTE _ x RO�Cz STANDARD SPECIFICATION a MaFwzo Ld 4 i EXCAVATION MAY BE WIDENED HDPE OR PVC cn ABOVE THE PIPE ZONE FITTING W/ {A I \ \ STAINLESS STEEL W J M cn \ YI ORDINARY MATERIALCPACTED GE 1 FULL JOINT :ii: PVCIAMETER AS FORCE MAIN ME N N a TRACER WIRE, SPLICED W/ (SEE PLANS p N N \ \ \ \ TRACER WIRE INSTALLED BY FOR DIAMETER) STAINLESS STEEL SUPPORT a x M w DIRECTIONAL DRILLING BRACKET & ANCHORS U) 00113 . . . . . . . . . . . "BEND . o o x d L p 2 N W zo op EMBEDMENT MATERIAL PER CITY OF LA PORTE W Q�' STANDARD SPECIFICATION ANCHORS BOLTS TO I- Q� BE EPDXYED INTO Z a. MANHOLE WALL Cw ADPE OR PVC FITTINGS W/ G BEDDING LAYER (GRANULAR STAINLESS STEEL BOLTS w EMBEDMENT, NOT COMPACTED) BEND POSITIONED SO THAT C WASTEWATER FLOW IS DIRECTED DOWN STREAM I 0 HDPE PIPE x ry 1 TYPICAL TRENCH SECTION 2 INTERNAL DROP MANHOLE w w NOT TO SCALE NOT TO SCALE Z d Q g W b 0 LL C) o ry Q C) I Q V) O 6"0 PIPE NOTES: ° 1 . USE MODEL S-316 LINK-SEAL MODULAR SEAL OR CORE BIT DRILL EXIST a M o APPROVED EQUAL. MANHOLE WALL PER ° a / z a M m J \ MANUFACTURER'S o Z W s o w N i 2. IF PIPE ENTRANCE IS THROUGH GROUT MATERIAL, REMOVE RECOMMENDATION o 0 0 � � o AND REPLACE ALL GROUT MATERIAL TO OBTAIN A GOOD / BOND. USE NON-SHRINK GROUT. / Z I 3. W J USE NON-SHRINK GROUT TO SEAL WALL PENETRATION. INSTALL "BUBBLE WRAP" BETWEEN LINK-SEAL AND GROUT PER MANUFACTURER'S RECOMMENDATION. m m La. C c ° LINK-SEAL INSTALLED PER MANUFACTURER'S RECOMMENDATION F o EXIST MANHOLE WALL Q c o a N i —�orncN 3 caN 3 TIE— INTO EXISTING MANHOLE DETAIL m: 8 - NOT TO SCALE o a vJ� j 0O N Off\ vN Z O ; O x E N SHEET c N N Q Li J SEQ. Plot Date: 1 13 2015 10:02 AM Plot By: fb Filename: N:\UTIL Record Drawings UTIL—DT—STD-01.dwg 3 N 0 I p .o N .. I T Q m I � J N p' O O iV) cn •3 d 0 Cpd^- U (1) -a N O N U _ of O v � r o�\ - z 0 o EN 0 pa ro rn U - a Q LZ J TEE PLUG W Q LLI a . a Q c � a a >1 „X„ E„ m 2000 P.S.I. CONCRETE A FOR 11'15' BENDS B FOR 22'30BENDS C FOR 45' BENDS D FOR 90' BENDS HORIZONTAL BLOCKING TABLE "X" 11°15' 22'30' 45` 900 TEE & PLUG PIPE SIZE FT. IN. MIN.. ART 2 IN MIN.. ART , •> » IN. MIN. ART 1D$ MIN/. ART 2 N. MINA. ART L 6" 1.0 9 1.04 13 2.07 18 4.05 24 7.49 20 10.59 8" 1.0 12 1.85 17 3.67 24 7.02 32 13.31 27 18.82 12" 1.25 18 4.15 25 8.26 35 16.20 48 29.94 40 42.34 16" 1.5" 24 7.38 34 14.68 47 28.81 64 53.23 54 75.28 BLOCKING NOTES : 1. CONTRACTOR SHALL VERIFY ALL SOIL BEARING STRENGTHS. 2. BEARING AREAS SHOWN ARE BASED ON 150 P.S.I. TEST AND 2,000 P.S.F. SOIL BEARING VALUE. 3. THE EARTH BEARING SURFACE SHALL BE UNDISTURBED MATERIAL. KEEP ALL FITTINGS FREE FROM CONCRETE. THRUST BLOCKS ARE TO BE CONSTRUCTED OF 2,000 P.S.I. (28 DAY) CONCRETE AND PLACED AS SHOWN ON TYPICAL THRUST BLOCKING DETAIL. 4. ALL VALUES ARE MINIMUM. IF SOIL BEARING VALUE IS LESS THAN 2000 P.S.F., CONTRACTOR SHALL HAVE A TEXAS REGISTERED PROFESSIONAL ENGINEER DESIGN THE NECESSARY THRUST BLOCKING. 5. VERTICAL DIMENSION OF BLOCKING SHALL BE IDENTICAL TO THE APPLICABLE HORIZONTAL (A,B,D,C,E) DIMENSION AS LISTED IN TABLE, OR GREATER. 6. DIMENSION "X" MAY VARY IF NECESSARY TO PROVIDE BEARING AGAINST UNDISTURBED TRENCH WALL. REINFORCING BARS ---- HORIZONTAL BLOCKING DETAIL NOT TO SCALE TRENCH WIDT Bd 2 a a. a . Q _ °'. .4 O Bd + 2' MIN 2 2 SECTION _ - - NOT TO SCALE lwaommC LENGTH AS BEND 3 SECTION - - NOT TO SCALE ASSUMED HORIZONTAL VERTICAL COMPONENT OF THRUST = TABULATED VALUE REINFORCING BARS #4 Q 12" C/C, FOR PIPE SIZES GREATER THAN 12" REINFORCING SHALL BE AS SPECIFIED BY ENGINEER GENERAL NOTES FOR ALL THRUST BLOCKS 1. CONCRETE FOR BLOCKING SHALL BE CLASS "B", PER SPECIFICATION 03 30 00. 2. ALL CALCULATIONS ARE BASED ON INTERNAL PRESSURE OF 200 PSI FOR DUCTILE IRON, P.V.C., AND 150 PSI FOR CONCRETE PIPE. 3. VOLUMES OF THRUST BLOCKS ARE NET VOLUMES OF CONCRETE TO BE FURNISHED. THE CORRESPONDING WEIGHT OF THE CONCRETE (CLASS "B", PER SPECIFICATION 03 30 00), IS EQUAL TO OR GREATER THAN THE VERTICAL COMPONENT OF THE THRUST ON THE VERTICAL BEND. 4. WALL THICKNESS (T) ASSUMED HERE FOR ESTIMATING PURPOSES ONLY. 5. POUR CONCRETE FOR BLOCK AGAINST UNDISTURBED EARTH. 6. DIMENSIONS MAY BE VARIED AS REQUIRED BY FIELD CONDITIONS WHERE AND AS DIRECTED BY THE ENGINEER. THE VOLUME OF CONCRETE BLOCKING SHALL NOT BE LESS THAN SHOWN HERE. 7. THE SOIL BEARING PRESSURES ARE BASED ON 2000 LBS./S.F. IN SOIL AND 4000 LBS./S.F. IN ROCK. THE CONTRACTOR SHALL INSPECT BEARING STRATA PRIOR TO POURING THRUST BLOCKS. SHOULD THE STRATA BE SOFT, SPONGY OR WEAK, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO POURING THE THRUST BLOCK. 8. USE 8 MIL POLYETHYLENE WRAP OR EQUAL BETWEEN CONCRETE AND BEND, TEE, OR PLUG TO PREVENT THE CONCRETE FROM STICKING TO IT. 9. CONCRETE SHALL NOT EXTEND BEYOND JOINTS. O O C O O = O V -zozz �o 8 rnjami w m O o of a: u,., o rn w 2�no:u� o IE�m;,=U ram ;� C C_ W U o Z M0? ' u w rn przn a ��Z� �3 F. Ti .. o o Q z m 0 w •- O �, C 2 p o c E o E W oo O ow W 0 O O O O rL-wam a`uwi 11.25' 22.50' 30' 45' 67.50' 90' . A I.D. (IN.) THRUST (TONS) VOL. (C.Y.) I THRUST (TONS) VOL. (C.Y.) THRUST (TONS) VOL. (C.Y.) THRUST (TONS) VOL. (C.Y.) THRUST (TONS) VOL. (C.Y.) THRUST (TONS) VOL. (C.Y.) I.D. (IN.) 4,6,8 1.0 0.5 2.0 1.0 2.5 1.3 3.6 1.8 4.6 2.3 5.0 2.5 4,6,8 10,12 2.2 1.1 4.3 2.2 5.7 2.8 8.0 4.0 10.5 5.2 11.3 5.7 10,12 16,18 5.0 2.5 9.7 4.9 12.7 6.4 18.0 9.0 23.5 11.8 25.5 12.7 16,18 VERTICAL BEND THRUST BLOCK a N E o L w ww Z f Er cw O v d d W N li 'rt x i� WJ M NO N W w •) o W= o^ Baas `co n o 00 y -t w n arry to m V X FM0 x 02 o O F N 3 00 O n 3 m 3 1 3 o o w I m c o xd (Noro w C O w :: �a.a�3 Z LiJ W U Q -I LiJ X ry w Z o Q o J -I LJJ G o ry 0 U I� n 4 f ry Q n Z Q n 0 1 w U 't O 3 Q N U z 0- M m J\ o o z o o N w O N cYi I Z N 6 = p � LO w Ow C14 p o Z I \ _J J F- � O } [Q a l - C OO C .°'o ai Oc6 c(1)N o c ,., O to C O'O -co C� O 0a) O nc� o" E m-a, p Lj p J Q 0 O ULd N }. X o W ,o SEQ. i te: 1 / 13/20 HE D 0 O O L) oN W 3� W E- 3^ W (n W J 0-1 In I In C)CO(n LL W O �x W I In J (7 Z SAD �%o J.. (n J /N vZ ON O a 0 In M O NON � M � ~ \_ a Q u0 rA1H NESS PISUBG E TOREN H OF ICEME OFD DRNEW APIUNTY TANDA ❑ NO F ❑ IKT/ FA ■ 17 AT LIl7 ON psi U TO TO 7, FL OD O OVKIS;dUQ,1CR1E RY STOR ATER TENTIO BASIN UTING BLE TENTION IN D CE AR - _ RES MAX DRAIN E (100 EVENT - _ OURS WA "MA ADDIT NAL C ERIA F PUMP DETE ON BA S: OLUME 0 PUMPED EXCEE CE STO VOLU C-FT ___ % 0 TOTAL ME MAXIMU ESIGN OW ITY IN] CFCD C NEL = __ �FF./SE ORAI IME FOR IN = ___ HOURS ED ON H CONDO S. TORMW R DR GE D IGN R RT RE TITLE EPORT E �_ __ ___� _ E EERING M DAT F ACKN EME BY HCF OR FLO LAIN AD ISTRATO HCFCD ROIECT ST MWATE ETENT FOR E PR SED K CO AWED THESE LANS PROVI- BY IER P S: P TITLE - _ - - ENGINEE G FIRM _ SIGNE BY HCFC ---- _ HC PROJE / I HCFCD TAN D NOTE SEE S T OF ESE P NS. III. FCD S DARD TAIj_S: EE SH F THE PLAN . REF TO P SHEE FOR STING D PRO SED T OF W DELIN ION A COMP E RE DING ORMAT TO I LUDE CLE 'S FIL UMBE TYPE F EST (e.g., RAINAG EASEM T, F STRIP TC.) G E (e.g OH, H CD, P IC, TX T, ETC /�—�_"• • rJi����! ''1ili'i(N]•il���!1�'L�3:.:.1II711 � NOTE&: I. COMPLETE ONLY IF HCFCD OR HARRIS COUNTY IS REQUIRING DETENTION. D. COMPLETE ONLY IF PROJECT HAS WITHIN IT OR IS IMMEDIATELY ADJACENT TO AN EXISTING OR '.. PROPOSED HCFCD MAINTAINED CHANNEL OR DETENTION BASIN. 01. COMPLETE ONLY IF PROJECT INCLUDES NEW OUTFALL BACKSLOPE INTERCEPTOR OR OTHER RELATED WORK WITHIN AN EXISTING OR PROPOSED HCFCD MAINTAINED CHANNEL OR DETENTION BASIN. N. COMPLETE ONLY OF PROJECT HAS WITHN OR IMMEDIATELY ADJACENT TO IT AN EXISTING OR PROPOSED PUBLIC DRAINAGE CHANNEL OR DETENTION BASIN. A. 0 X $, FLOOD PLAIN STATUS 1. GENERAL INFORMATION FIRM PANEL(S) FOR PROPERTY: 4S2O1C1O85L FIRM PANEL(S) DATE: STATUS OF PROPERTY ON MAP ❑ ENTIRELY LOCATED IN UNSHADED ZONE "X" ❑ LOCATED PARTIALLY IN ANY "A" ZONE OR SHADED ZONE "X", DELINEATE FLOODPLAIN BOUNDARY ON CONSTRUCTION DRAWINGS (DRAINAGE LAYOUT PG. N0.___-_) (BASE FLOOD LEVEL_____) ® LOCATED ENTIRELY IN ANY "A" ZONE OR SHADED ZONE "X", (INDICATE BASE FLOOD LEVEL ELEV. 11 ) ❑ LOCATED IN THE 10-YEAR FLOODPLAIN ❑ LOCATED IN CYPRESS CREEK LOMR 08-06-2369P (INDICATE BASE FLOOD LEVEL__--____--_) ❑ SITE REMOVED FROM FLOODPLAIN BY LOMA OR LOMR-F CASE N0.---------------------- ❑ OTHER ELEVATION INFORMATION BENCHMARK USED ® HARRIS COUNTY FLOODPLAIN REFERENCE MARK ❑ HARRIS-GALVESTON COASTAL SUBSIDENCE DISTRICT BENCHMARK (FOR COASTAL AREAS) DESCRIPTION OF BENCHMARK INCLUDING ELEVATION, DATUM AND YEAR OF ADJUSTMENT (2001 ADJ.) FLOODPLAIN REFERENCE MARK NUMBER 010270 IS A BRASS DISC STAMPED 010270 IN B21DGE OVER TAYLOR BAYOU IN KEYMAP 5BOP NEAR STREAM A104-00-00 ELEV. 6.61 NAVD 198B, (2001 ADJUSTMENT TSAtRP)• It._FLOOD PLAIN DETERMINATION BASED ON GROUND ELEVATION ❑ PROPERTY LIES ENTIRELY ABOVE THE BASE FLOOD LEVEL AND IN SHADED ZONE "X" ® PROPERTY LIES PARTIALLY OR ENTIRELY BELOW THE BASE FLOOD LEVEL III. FLOODPLAIN STORAGE SUMMARY FLEES O LY O POR IONTED Or FIND LOCATED WITHIN A. TOTAL VOLUME OF MATERIAL PROPOSED TO BE PLACED WITHIN THE FIRM DELINEATED FLOODPLAIN (FILL, BASE, CONCRETE, ASPHALT, ETC.): i.e., BELOW ELEVATION 11 (2001 ADJ.) 0 CUBIC YARDS B. TOTAL VOLUME OF MATERIAL PROPOSED TO BE REMOVED FROM THE FIRM DELINEATED FLOODPLAIN: i.e., BELOW ELEVATION 111 (2001 ADJ.) 0 CUBIC YARDS C. FILL AREA IN FLOODPLAIN IS SHOWN ON SHEET N/A_ NOTES: 1. COMPLETE FOR ALL PROJECTS D. COMPLETE ONLY IF PROJECT IS ADJACENT TO 100-YEAR FLOOD PLAN IV ❑LOMR REQUIRED ❑CLOMR REQUIRED VERIFIED BY: 4, WATER AND WASTEWATER I. TYPE OF SERVICE PROPOSED 0 MUNICIPALITY: CITY OF LA PORTE ❑ MUNICIPAL UTILITY DISTRICT: ❑ OTHER DISTRICT: ❑ PRIVATE WATER AND WASTEWATER SYSTEMS ❑ PRIVATE WATER SYSTEM AND INDIVIDUAL OSSF ❑ INDIVIDUAL WATER WELL AND OSSF ❑ OTHER: H.C. WASTE WATER PERMIT/REQUEST NO. II. PROOF OF CAPACITY ❑ LETTER FROM DISTRICT AUTHORIZING SERVICE AND CONNECTION ❑x TCEQ APPROVAL FOR WATER SYSTEM AND PERMIT FOR WASTEWATER SYSTEM. ❑ OSSF SUBDIVISION PLANNING REPORT • ' s�� ■ 01111111194 19 • • •' ���----� FORPRO3ECISLOCATM IN ANY FIAODp W Den'opmatmmnaaNwplomdln a®Nanm »{Ib Noepfmu wW mmplY x{lAaupm:Gbm oflhe RegWaRom oJNaTr6 Cmmry. TmufwFWo�dain Managonrnt No ndnu b d/oned In dmnood p/a/n and wJUI U dlaxW In the/loodxay. FOUNDATION NOTES:(,ypHamnyYABgrwddl6gnlfdeurryetAyndavppw&) All xnfaheaurafumam, dTmndl4onfng wW, ekdrim(dbMbuffonpaw$ and arty oWv mechmkd wtlaWmitqulpmml malbedewfrd WamNws x{Ih Seetlon 4.03 offf w Cowry ffoadplda"g ka m, Any deddmldm TavWg a RgM"dbh wmdi tw e{befowthe Gme(10063 ,Inoodelemdon ThaRbe dioppedfiom above and be m a apmob bnvW. All matnf.Ir u,d bdaw de(f00. ) bmenoaddnnttom. wapprn. d FEW rbd..d gm'n2.93m a=J»wervm4wa, ardoppraml inamrtbna »idr F MA T.-A dM 11.11N 1.93fwfawda opmfngx ffdmproperty k bmfd w %ak dafg wd 10%jb.a A.wnn-1®naa/plo;n all mrufrvcRm pfmnrmfy/ov(14)f h.abme du b.eJ 9" noiseurc mawwy, mrmne wThe( lhaemafnbls mat be andlwpfa; roGmm,andfmmdaAoa »vlt: Gaummbn oJafnml emefadiidn onlaml/wwM(sWwdm ban (100.3ea)Jloodekmtlw btheSOOpmrJloodpldnwxirhfn t5eb=(100.}mr)naadpWnThall bm du lowat)laor ekmtMrodnm/rawmmeaboneheb=Jlooddemdam i'bwtpmalmgandamli�mmwuanalbemken mem�seha mdeTub,fonm wRlnothdirylad bywnlmmllmoJiaodxmm. A6Y"IOWm Liem(dmwaMrtdle/elYiaflAe Am[nOYfThaR4YpmddatmaRCddmlJadWfmm dmrsrwpavblC ComokW•Ekmtbn Cgdfu lobe nbwftak mmmanWln¢. awmadgaafhe,kh6aoumlorTabilow4Wldl"{aMWonf/m fmm/n¢T1mD. anda 1hkdU rmulmfonaranLdn"hd. •(PARCf/AREM17p7RMPANEi)mlhe Narrb Cvmaypublkfnfimhurlme AreAlfamrtaMEngfnming Oivkbm 10S33 A'otthnvt f�, 120, H Sdb 110, ourtmr, 3X 71091 AmmpiemdmbaW aert�mfemmf bembmiado/fa dmTlruNueum�ldeand6QaeR4amgiiai The Cawty6� fJfflmwWpaaaJfxdln,peNan mike on daTaucuvaanmaUrolWrmiaiabmeka,mu. NOTES: 1. - IR. REOUIRED ON PROJECTS WITH WORK IN A HCFCD CHANNEL PLEASE REFERENCE SECTION 17 OF THE FLOOD CONTROL DISTRICT POLICY, CRITERIA, AND PROCEDURE MANUAL FOR MORE INFORMATION. EXPRESS REVIEW SHEET 12.1 May 26, 2011 $ • DESCRIPTION OF PROPERTY 1. LEGAL DESCRIPTION A. ACREAGE: B. ❑ SUBDIVISION: ❑ SURVEY & ABSTRACT: C. ADJACENT ROADS:OLD HWY 146, SHORE ACRES, W_ FORFST_ FAIRFIFI n / PLAT El V. UNOBSTRUCTED VISIBILITY EASEMENT (U.V.E.) ❑ REQUIRED AND SHOWN ON SHEET(S) ® NOT REQUIRED KEY MAP®page(S)---- _______--- *CPC 101 FORM MAY BE REQUIRED 10• PERMITS REQUIRED T L ESTI TED SI CONS CTION DST, XCLUD ENC ED B ❑ ORM ER QU ITY PHA II PE IT CLA 1 ❑ P ASE II ?MIT SS 11 CRI L FACI DR AY WIT CULVE __ CURB D GU R E]S IC (E TING) SEPT (PROP ED) NOTIC OF D TION QUIRE ❑ FI AFFIDA REQU D BUILD] PERM (N0. BUIL GS = __ SU ISION FRAST CTURE ASE 11 0 OF OTS OTES: WORK IN HARRIS COUNTY R.O.W. ® UTILITY FQRCE_�IAIN ® CONSTRUCTION EQRX_MAIN ❑ OTHER _____________ 11 CURB RAMPS / SIDEWALK CURB RAMPS PROPOSED ❑ YES ® NO SIDEWALKS PROPOSED ® NO A. HOME BUILDER ❑ YES B. DEVELOPER ❑ YES C. H.O.A. ❑ YES 0. OTHERS 12 LANDSCAPING ❑ REQUIRED AND SHOWN ON SHEET(S) [10 NOT REQUIRED NOTES: A PERMIT IS REQUIRED FOR EACH SCOPE OF WORK ON SITE. A NOTIFICATION IS REQUIRED FOR EACH SCOPE OF WORK IN HC OR HCFCD ROW. REFER TO www.eng.hctx.net/Dermits FOR EACH SCOPE OF WORK IN HC OR IN HCFCD ROW. This Record Drawing is a combination of the sealed engineering contract drawings for this project, modified by information furnished by the contractor reflecting changes in the Project made during construction. The original sealed drawings ore on file at the offices of FREESE AND NICHOLS, INC. 4055 INTERNATIONAL PLAZA, SUITE 200 FORT WORTH, TEXAS 76109-4895 (817) 735-7300 RECORD DRAWINGS PREPARED ON: 1/7/2015 (, STORM WATER QUALITY I. CONSTRUCTION PROTECTIVE MEASURES. ❑ SWPPP SITE PLAN AND DETAILS ON SHEET(S) NIA II. APPLICABILITY FOR PERMANENT FEATURES. ❑ EXEMPT NEW DEVELOPMENT OF LESS THAN 5 ACRE PARCEL. T EXEMPT REDEVELOPMENT OF A 5 ACRE OR LARGER PARCEL WHERE TOTAL IMPERVIOUS SURFACE (EXISTING PLUS PROPOSED) IS LESS THAN 1 ACRE. ❑ EXEMPT "GRAND FATHERED" BY AN EXISTING STORM SEWER LINE. ❑ STORM WATER QUALITY PERMIT REQUIREMENT FOR THIS PROJECT IS COVERED BY-------------------------**. ❑ "STORM WATER QUALITY MANAGEMENT PLAN" INCLUDED. SWAMP SITE PLAN ON SHEET(S)--------------------------------- ON NOTES: I - 11 REOUIREO ON ALL PROJECTS, III IF NOT EXEMPT OR 'GRANDFATHERED' * * INCLUDE: PROJECT TITLE, HARRIS COUNTY PROJECT NUMBER, AND SAID PERMIT NUMBER, OR THE NAME OF THE PERMITTING AUTHORITY IF OTHER THAN HARRIS COUNTY. HCPID SIGNATURE BLOCK PROJECT NAME: LIFT STATION NO. 39 FORCE MAIN REPLACEMENT ADDRESS: CITY OF LA PORTE WAS ACCEPTED BY THE FOLLOWING GROUPS FOR THE PURPOSES LISTED BELOW: ENGINEERING DIVISION BY INTERPOSE NO OBJECTION By AS TO PAVING AND/OR DRAINAGE ONLY BY AS TO LOCATION OF ITEMS IN COUNTY RIGHT OF WAY BY AS TO STORM WATER DUALITY ADDITIONAL COMMENTS: DATE DATE DATE 6/17/14 DATE HARM COUNTY FLOOD CONTROL DISTRICT INTERPOSE NO OBJECTION BY DATE FOR ITEMS LOCATED OUTSIDE OF HCFCD RIGHT-OF-WAY APPROVED: BY DATE FOR ITEMS LOCATED WITHIN EXISTING HCFCD RIGHT-OF-WAY APPROVED: BY DATE FOR ITEMS LOCATED WITHIN PROPOSED HCFCD RIGHT-OF-WAY ADDITIONAL COMMENTS: CHANNEL a# A104-11-00 THE PROJECT WAS REVIEWED HOWEVER THIS DOES NOT MEAN THE ENTIRE PRO JECT, INCLUDING ALL SUPPORTING DATA AND CALCULATIONS HAVE COMPLETELY H VE BEEN LETEL COM CHECKED AND VERIFIED. THESE DRAWINGS ARE SIGN AT ED, DATED AND SEALED BY A PROFESSIONAL ENGINEER LICENSED TO PRACTICE IN THE STATE OF TEXAS, WHICH THEREFORE CONVEYS THE ENGINEER'S RESPONSIBILITY AND ACCOUNTABILITY. THIS DOES NOT RELIEVE ANY PARTY FROM COMPLYING WITH APPROPRIATE FEDERAL, STATE AND LOCAL ENVIRONMENTAL RULES, LAWS, AND REGULATIONS AND ANY OTHER LEGALLY ADOPTED REGULATION OR ORDINANCE RELATED TO LAND DEVELOPMENT. IF THE CITY SIGNATURES ARE REOUIRED BY ORDINANCE, COUNTY PERMITS WILL NOT BE ISSUED UNTIL SUCH SIGNATURES ARE OBTAINED. THESE SIGNATURES ARE VALID FOR A MAXIMUM OF TWO YEARS.'.. ENGINEER'S CERTIFICATION I; WILLIAM HERNDON, A LICENSED PROFESSIONAL ENGINEER IN THE STATE OF TEXAS, DO HEREBY CERTIFY THAT THE INFORMATION PRESENTED ON THIS SHEET IS TRUE AND CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT I AM NOT VIOLATING ANY PROVISION OF THE CURRENT TEXAS ENGINEERING PRACTICE ACT AND RULES CONCERNING THE PRACTICE OF ENGINEERING AND PROFESSIONAL ENGINEERING LICENSURE. ANY VIOLATIONS WILL BE FORWARDED TO THE HARRIS COUNTY DISTRICT ATTORNEY'S OFFICE FOR PROSECUTION. THE COMPLETED PROJECT CONSISTS OF DRAWING SHEETS 1 THRU —9_ . S EAL 6/12/14 SIGNATURE DATE THE SEAL THAT ORIGINALLY APPEARED ON THIS DODO c 7�� �r TEXAS AUTHORIZED N0: 97312�WAONC 6 H12 NDON 1 J2014 R E V I S I 0 1V S ALTERATION OF A SEALED DOCUMENT WITHOU NOTIFICATION OF THE RESPONSIBLE ENGINEEF OFFENSE UNDER THE TEXAS ENGINEERING PF Qt RECORD DRAWING FB 1/7/2015 DATE SHEET NO. DESCRIPTION P.E. INITIAL H.C. APPRO\ 6 12 14 1 Added Key Mop No. and Channel ID Nos. WCH 6/12/14 3 Added Channel ID No. WCH , PROJECT NO. PROPER (I IS AN