HomeMy WebLinkAboutSULZER TURBO SERVICES SITE PLAN (13)CD
Q
NOTE: ITEMS THAT ARE NOT SHOWN
AS (PROPOSED) ARE EXISTING
VICINITY MAP:
� Hy
A ro oFER ps
N s>oN
?g <A p N
AcRes �RTF RpgO N
KEY MAP: 539R
N�•NG�f'
LANDSCAPE LEGEND:
a Ash
BB
Bottle Brush
CY
Cyprus
LO
Live Oak
Magnolia
Holly
Oak
Pi
Pine
PI
Plum
Talon
WM
Wax Myrtle
Crepe Myrtle
p Landscape
Shrubs
SITE LEGEND:
•
I.R. Found '
Property Line
—B.L.—
Building Setback Line
O
(Record Call)
�- �-
Wood Fence
6'-0" Chain Link Fence
8'-0" Concrete Fence
-fl-0--
--
Sanitary Sewer
--
Water Line
x oe
Existing Elevation
0.00
Proposed Elevation
CONC
Concrete
Asphalt
CALICHE
Caliche
Grass
Proposed Grass
Proposed Conc.
PpC00N
' W r �ee�Zg7:l
S g94447j.' W ..
is a9.
�OZ 9
FIRE APPARATUS ACCESS
ROAD (60-FOOT "Y")
�(7) EXISTING PARKING
p$ SPACES TO BE REMOVED FriMPOSED
SCOPE
OF
WORK:
m � IYAV/ Ili\
Y: AIR COMPRESSOR TO BE
RELOCATED. LOCATION TO
BE DETERMINED.
may O CORE BUILDING EXPANSION
1.1 3,150 SO.FT. FOUNDATION
1.2 3,150 SOFT. BUILDING
1.3 REMOVE (7) EXISTING PARKING SPACES
NOTES:
1. THERE WILL BE NO NEW OR PROPOSED UTILITIES
I.E. ELECTRICAL SERVICE, WATER, SANITARY SEWER,
STORM SEWER AND NATURAL GAS.
2, PROPOSED BUILDING IS OVER EXISTING 8"
CONCRETE PAVING.
3. COMPRESSOR BUILDING TO BE RELOCATED AND
ACCESS PAVING TO BE ADDED WITHIN 1YR FROM
DATE OF PERMIT.
ABBREVIATIONS:
NOTE: ALL ITEMS NOTED ON
PLAN ARE
EXISTING UNLESS NOTED
'PROPOSED'.
CB
Catch Basin
MOP
Mounted On Pole
CO
Clean Out
O.C. E.W.
On Center Each Way
CONC
Concrete
PL
Pipe Line
DWL
Design Water Level
PM
Pole Mounted
FDC
Fire Department
PP
Power Pole
Connection (Sprinkler)
PROP.
Proposed
EXIST.
Existing
RCP
Reinforced Concrete Pipe
FH
Fire Hydrant
RE
Reference
GM
Gas Meter
HB
Hose Bib
SS
San Sewer
LSC
Landscaping
UES
Underground
LP
Light Pole
Electrical Service
MH
Man Hole
WM
Water Meter
MIN.
Minimum
WV
Water Valve
XFMR
Transformer
PARKING REQUIREMENTS:
]INIM14900110
EXISTING
PARKING AS
OF 03.26.15
= 386
PARKING
IN RESERVE
AS OF 03.26.15
= 94
EXISTING
PARKING TO
BE REMOVE
= 7
REQUIRED
PARKING
6 NEW EMPLOYEES
6/1.5 EMPLOYEES
= 4
PARKING
TO REMAIN
IN RESERVE
= 83
BUILDING/LANDSCAPING COVERAGE
TOTAL LOT = 1,265,605.87 SO. FT.
EXISTING BLDGS. = 343,861.10 SQ. FT.
PROPOSED BLDG. EXPANSION = 3,150.00 SO. FT.
TOTAL PROP. + EXIST. BUILDINGS = 347,011.10 SQ. FT.
PERCENTAGE BLDG COVERAGE = 27.42 %
1�onc-T '00me : ;a,
-NQE: 3l�► Add.t o�
fwrGsS t S�� otd tom.Poc Rd►• L
. PfW �i A�%• °�' fn '�.'l.'4glo aGft. "Ffow�'
LEfoAI.•• , �A
55� A•11
SULZER TURBO SERVICES
11518 OLD LA PORTE ROAD
LA PORTE, TEXAS 77571
INDUSTRIAL COMPLEX
LA PORTE WORKS
1,265,605.87 SQ. FT. LIGHT INDUSTRIAL
29.0543 ACRES
LA PORTE OUTLOTS 338�. 83,507 SOFT 1.9170 ACRES
338 83,428 SOFT 1.9152 ACRES LL RESIDENTIAL
(347A-2 i 129,161 SOFT 2.9651 ACRES
347A-1A/
SITE INFORMATION:
PREVIOUSLY PART OF A 22.6070 ACRE TRACT
KEY MAP: 539R
NAME OF DEVELOPMENT: SULZER TURBO SERVICES
TYPE OF DEVELOPMENT: RE: PROPOSED SCOPE OF WORK
OWNER: SULZER TURBO SERVICES
BUILDER: FOLLIS CONSTRUCTION, INC.
ZONED: LIGHT INDUSTRIAL/LARGE LOT RESIDENTIAL
JOB ADDRESS: 11518 OLD LA PORTE ROAD
BENCHMARK IS FINISHED FLOOR IN EXISTING BUILDING=7—
BENCHMARK ELEVATION IS 21_16'
OWNER: SULZER TURBO SERVICES
11518 OLD LA PORTE ROAD
LA PORTE, TEXAS 77571
SURVEYOR: C.B. URBAN
2534-8 VIOLET STREET
PASADENA, TEXAS 77503
(281) 487-2251
NAICS CODE 811310
NOTE: FLOOD ZONE — 'X'
THIS TRACT IS NOT WITHIN THE 100 YEAR FLOOD PLAIN
MAP NO. 48201CO935L DATED JUNE 18, 2007
DETENTION REQUIREMENTS:
EXISTING REQUIREMENTS:
EXISTING REQ. IMPERVIOUS AREA = 131,085 SQ.FT. = 3.01 ACRES
PROPOSED IMPERVIOUS AREA = 810
TOTAL = 131,895 SQ.FT. = 3.02 ACRES
EXISTING DETENTION RATE REQUIRED = 0.55 AC —FT /ACRE
REQUIRE DETENTION: 131,895 X 0.55 = 72,543 CU. FT.
PROPOSED BUILDING IS OVER EXISTING IMPERVIOUS
AREA. NO ADDITIONAL DETENTION REQUIRED.
DETENTION CALCULATIONS:
INTERIM DETENTION — DESIGN WATER_ LEVEL OF 20.00'
PROVIDED AREA
35,848
SQ.
FT.
VOLUME AT
3.75' WITH A FLOW OF 16.25'
134,430
CU.
FT.
REQUIRED
DETENTION
AS OF 03.26.15
72,543
CU.
FT.
REMAINING
DETENTION
RESERVE
62,333
CU.
FT.
(INCLUDES
PROPOSED
IMPERVIOUS AREA)
ULTIMATE
DETENTION
— DESIGN WATER LEVEL OF
20.00'
PROVIDED
AREA
35,848
SQ.
FT.
VOLUME WITH AVERAGE DEPTH OF 5.36'
192,145
CU
FT.
REQUIRED
DETENTION
AS OF 12.29.14
72,543
CU.
FT.
REMAINING
DETENTION
RESERVE
119,602
CU.
FT.
I, HAMID R. SHOTORBANI, AM REGISTERED UNDER THE LAWS
OF TEXAS TO PRACTICE THE PROFESSION OF ENGINEERING
AND HEREBY CERTIFY THAT THIS MINOR SITE PLAN IS
TRUE AND CORRECT AS TO PROPOSED SITE IMPROVEMENTS,
HAMID R. SHOTORBANI P.E.
TEXAS REGISTRATION NO. 55164
This is to certify that the City of La Porte, Texas has
approved this site plan and development of SULZER TURBO
SERVICES-RE:_PROPOSED SCOPE OF WORK_ in conformance
with the laws of the State of Texas and the ordinances
with the of the City of Lo Porteqito-r,qa
By.- - -----
Port Planning
Department
Attest:
By: By: --kl!g-7o
-LaPorte CEngineer La City Planner
P.O. Box 1115
604 West Fairmont Parkway
Lo Porte, Texas 77571-6215
N
m
U
o
1
C:
��
U
N N
�
L
�
0
O
U
L
t
T
^'
4N
N
a)
V
V
p
'C3
U
m
U)
C
O
c�
m d
LLCU
Z a
0
r
ti
ti
O
ti
W f- CC/)
Q
m In W
W
CL
Elf
cf)
W 0 0
W
J��
Lo
0
Cn
0
0
�n
U
o
SEAL
a F i
��
�P�6
m •.*°r
N
*5.••
d*: *o
o ••HAMi� R. SHOTORBANI p
N
,,P. 55164
rp a
5;��iSTER.�G
�0a �oq� �1
Q
N
c
at Q
LO
ri
A � �
P 0 0
�j N
DRAWN BY
AW
CHECKED BY 4
JMF
SCALE
1 " = 100,
DATE
03.26.2015
JOB NO
3220N
M
c4av, A-j