Loading...
HomeMy WebLinkAboutSULZER TURBO SERVICES SITE PLAN (13)CD Q NOTE: ITEMS THAT ARE NOT SHOWN AS (PROPOSED) ARE EXISTING VICINITY MAP: � Hy A ro oFER ps N s>oN ?g <A p N AcRes �RTF RpgO N KEY MAP: 539R N�•NG�f' LANDSCAPE LEGEND: a Ash BB Bottle Brush CY Cyprus LO Live Oak Magnolia Holly Oak Pi Pine PI Plum Talon WM Wax Myrtle Crepe Myrtle p Landscape Shrubs SITE LEGEND: • I.R. Found ' Property Line —B.L.— Building Setback Line O (Record Call) �- �- Wood Fence 6'-0" Chain Link Fence 8'-0" Concrete Fence -fl-0-- -- Sanitary Sewer -- Water Line x oe Existing Elevation 0.00 Proposed Elevation CONC Concrete Asphalt CALICHE Caliche Grass Proposed Grass Proposed Conc. PpC00N ' W r �ee�Zg7:l S g94447j.' W .. is a9. �OZ 9 FIRE APPARATUS ACCESS ROAD (60-FOOT "Y") �(7) EXISTING PARKING p$ SPACES TO BE REMOVED FriMPOSED SCOPE OF WORK: m � IYAV/ Ili\ Y: AIR COMPRESSOR TO BE RELOCATED. LOCATION TO BE DETERMINED. may O CORE BUILDING EXPANSION 1.1 3,150 SO.FT. FOUNDATION 1.2 3,150 SOFT. BUILDING 1.3 REMOVE (7) EXISTING PARKING SPACES NOTES: 1. THERE WILL BE NO NEW OR PROPOSED UTILITIES I.E. ELECTRICAL SERVICE, WATER, SANITARY SEWER, STORM SEWER AND NATURAL GAS. 2, PROPOSED BUILDING IS OVER EXISTING 8" CONCRETE PAVING. 3. COMPRESSOR BUILDING TO BE RELOCATED AND ACCESS PAVING TO BE ADDED WITHIN 1YR FROM DATE OF PERMIT. ABBREVIATIONS: NOTE: ALL ITEMS NOTED ON PLAN ARE EXISTING UNLESS NOTED 'PROPOSED'. CB Catch Basin MOP Mounted On Pole CO Clean Out O.C. E.W. On Center Each Way CONC Concrete PL Pipe Line DWL Design Water Level PM Pole Mounted FDC Fire Department PP Power Pole Connection (Sprinkler) PROP. Proposed EXIST. Existing RCP Reinforced Concrete Pipe FH Fire Hydrant RE Reference GM Gas Meter HB Hose Bib SS San Sewer LSC Landscaping UES Underground LP Light Pole Electrical Service MH Man Hole WM Water Meter MIN. Minimum WV Water Valve XFMR Transformer PARKING REQUIREMENTS: ]INIM14900110 EXISTING PARKING AS OF 03.26.15 = 386 PARKING IN RESERVE AS OF 03.26.15 = 94 EXISTING PARKING TO BE REMOVE = 7 REQUIRED PARKING 6 NEW EMPLOYEES 6/1.5 EMPLOYEES = 4 PARKING TO REMAIN IN RESERVE = 83 BUILDING/LANDSCAPING COVERAGE TOTAL LOT = 1,265,605.87 SO. FT. EXISTING BLDGS. = 343,861.10 SQ. FT. PROPOSED BLDG. EXPANSION = 3,150.00 SO. FT. TOTAL PROP. + EXIST. BUILDINGS = 347,011.10 SQ. FT. PERCENTAGE BLDG COVERAGE = 27.42 % 1�onc-T '00me : ;a, -NQE: 3l�► Add.t o� fwrGsS t S�� otd tom.Poc Rd►• L . PfW �i A�%• °�' fn '�.'l.'4glo aGft. "Ffow�' LEfoAI.•• , �A 55� A•11 SULZER TURBO SERVICES 11518 OLD LA PORTE ROAD LA PORTE, TEXAS 77571 INDUSTRIAL COMPLEX LA PORTE WORKS 1,265,605.87 SQ. FT. LIGHT INDUSTRIAL 29.0543 ACRES LA PORTE OUTLOTS 338�. 83,507 SOFT 1.9170 ACRES 338 83,428 SOFT 1.9152 ACRES LL RESIDENTIAL (347A-2 i 129,161 SOFT 2.9651 ACRES 347A-1A/ SITE INFORMATION: PREVIOUSLY PART OF A 22.6070 ACRE TRACT KEY MAP: 539R NAME OF DEVELOPMENT: SULZER TURBO SERVICES TYPE OF DEVELOPMENT: RE: PROPOSED SCOPE OF WORK OWNER: SULZER TURBO SERVICES BUILDER: FOLLIS CONSTRUCTION, INC. ZONED: LIGHT INDUSTRIAL/LARGE LOT RESIDENTIAL JOB ADDRESS: 11518 OLD LA PORTE ROAD BENCHMARK IS FINISHED FLOOR IN EXISTING BUILDING=7— BENCHMARK ELEVATION IS 21_16' OWNER: SULZER TURBO SERVICES 11518 OLD LA PORTE ROAD LA PORTE, TEXAS 77571 SURVEYOR: C.B. URBAN 2534-8 VIOLET STREET PASADENA, TEXAS 77503 (281) 487-2251 NAICS CODE 811310 NOTE: FLOOD ZONE — 'X' THIS TRACT IS NOT WITHIN THE 100 YEAR FLOOD PLAIN MAP NO. 48201CO935L DATED JUNE 18, 2007 DETENTION REQUIREMENTS: EXISTING REQUIREMENTS: EXISTING REQ. IMPERVIOUS AREA = 131,085 SQ.FT. = 3.01 ACRES PROPOSED IMPERVIOUS AREA = 810 TOTAL = 131,895 SQ.FT. = 3.02 ACRES EXISTING DETENTION RATE REQUIRED = 0.55 AC —FT /ACRE REQUIRE DETENTION: 131,895 X 0.55 = 72,543 CU. FT. PROPOSED BUILDING IS OVER EXISTING IMPERVIOUS AREA. NO ADDITIONAL DETENTION REQUIRED. DETENTION CALCULATIONS: INTERIM DETENTION — DESIGN WATER_ LEVEL OF 20.00' PROVIDED AREA 35,848 SQ. FT. VOLUME AT 3.75' WITH A FLOW OF 16.25' 134,430 CU. FT. REQUIRED DETENTION AS OF 03.26.15 72,543 CU. FT. REMAINING DETENTION RESERVE 62,333 CU. FT. (INCLUDES PROPOSED IMPERVIOUS AREA) ULTIMATE DETENTION — DESIGN WATER LEVEL OF 20.00' PROVIDED AREA 35,848 SQ. FT. VOLUME WITH AVERAGE DEPTH OF 5.36' 192,145 CU FT. REQUIRED DETENTION AS OF 12.29.14 72,543 CU. FT. REMAINING DETENTION RESERVE 119,602 CU. FT. I, HAMID R. SHOTORBANI, AM REGISTERED UNDER THE LAWS OF TEXAS TO PRACTICE THE PROFESSION OF ENGINEERING AND HEREBY CERTIFY THAT THIS MINOR SITE PLAN IS TRUE AND CORRECT AS TO PROPOSED SITE IMPROVEMENTS, HAMID R. SHOTORBANI P.E. TEXAS REGISTRATION NO. 55164 This is to certify that the City of La Porte, Texas has approved this site plan and development of SULZER TURBO SERVICES-RE:_PROPOSED SCOPE OF WORK_ in conformance with the laws of the State of Texas and the ordinances with the of the City of Lo Porteqito-r,qa By.- - ----- Port Planning Department Attest: By: By: --kl!g-7o -LaPorte CEngineer La City Planner P.O. Box 1115 604 West Fairmont Parkway Lo Porte, Texas 77571-6215 N m U o 1 C: �� U N N � L � 0 O U L t T ^' 4N N a) V V p 'C3 U m U) C O c� m d LLCU Z a 0 r ti ti O ti W f- CC/) Q m In W W CL Elf cf) W 0 0 W J�� Lo 0 Cn 0 0 �n U o SEAL a F i �� �P�6 m •.*°r N *5.•• d*: *o o ••HAMi� R. SHOTORBANI p N ,,P. 55164 rp a 5;��iSTER.�G �0a �oq� �1 Q N c at Q LO ri A � � P 0 0 �j N DRAWN BY AW CHECKED BY 4 JMF SCALE 1 " = 100, DATE 03.26.2015 JOB NO 3220N M c4av, A-j