Loading...
HomeMy WebLinkAboutVANEZIA PROPERTIES SITE PLAN (AMENDMENT #2)\ FLOODWAY ZONEAE� PERF.E.M.A., fPER F.E.M.A., F.I.R.M. F.I.R.M. 48201C0945L 48201CO945L 300'-0" i EXISTING 8" WATER LINE \ EXISTING 8" WATER LINE Pipelhe Marker-� F.N. �F EXISTING FIRE HYDRANT 3 ¢ PROPOSED NORTH E STREET FIRE HYDRANT Z PROP. 11/2"DOMESTIC WATER ¢ s=,;m y e,.e. Mn PROP, 1 112" \ (VARIES R.O. W) RE: CIVIL METER W/ 1 1/2" TAP Rim ,a O ! i ;"2-rzn (waN) IRRIGATION METER PROP. 1 i/2"DOMESTIC WATER a ' FL-,267 (f) METER W/ 1 1/2"TAP 206'-0" PROP. 1112" IRRIGATION METER /10'B.L. 801•0" PROP. 1 1 2" P - EX. 8" PVC SANITARY SE WER P Nhe Marker Rlm= 18.95n/[ory EX. 8"PVC SANITARY SEWER DOMESTIC WATER SERVICE .. �' ...-._ �. 1519 a=6.95 (Nk5) GA. P. P.P. FL N J5 (W) rz_rzsy � ENdnn L+Wwppy' T6W o o 3 PROP. 4" 0 PVC-40 @ 2% N 10' B.L. SETBACK 25k25' D 0 o SLOPE TO SAN. SEWER 4'-6 1/16" VISIBILI PROP. 4" 0 PVC-40 @ 1 % S EW 6' HIGH HAIN INK F CE PROPOSED '�''� TRIANGLE TO SAN. SEWER RPZ BACKFLOW \ ( PROP. SAN. SEWER ( I I SAMPLE WELLS PROP. 1 112" PVC-40 DOMEST WATER SERVICE I ( I IO P I Rc�sI I UNDERGROUND ELECT. SERVICE 55'-0" FROM METER TO P.P. I ( 151'-0" a bQrM '.LIGHTS. ° d ° ° a° d 14 �'. TRUCK WCLL4' ° veo d ° d 41. PHASE 1 p a d ° v v ° e d°. P OPOSED METAL e d 175 W. METAL HALIDE WALL o BUILDING "A" ° - ,'175W.. METALHALIDE.WALL , d ° d PAC( IN/P,HOTOCEIrL (7YP). PACK W/ PHOTOCELL(TYP) „� I 12,000 S.F. d d ° ° •,0 (AUTO SHOP) ° ° ° dt 20.50 F.F. d . a °. ° .. ° v e b. T-4 9116" v O ° � e " .d 4'-10112" ° 1y e e O °,. i e ° m I� o ° e d. CO a d e a d N v 1 O I U ° d ° a ° ° EXISTING EXXON PIPELINE Oe m W PROP.' ME ER.&° ° d CL MAIN DISC. °�'-0" ®.° e ° a d .. 2 0" 0: O J m d- ° e ° .d ° 3-0 , 2 3 °' UI z 2 ° 34• % 0" 2'-2"(3SPACES) 19'- " 35'-0" 20'-0" 10'-6" 91=6" I uW ILl ILl ¢ ° O i -�-1111 II N ° U PJZ < ESSIQLE _ 5�-8" °d v o° . ° Cq Q I P KING $$$AC ° `y d ° 4'-3 1/16" 2 co � m 2 EDP'TAII ° ° °.. ° ° ° LIGHTS I �^ Z-p v ° d° v.- 1' 1 d O 0 3�, eDMPATER .ZONEAE o SiE DETAIL ° ✓ ^` ° I W o d PERF.E.ry1.k d FLOODWA'Y m �l F.LRaM. \ PERFE.MA., w / ( ZO(SHNE X) L J' �' Al. ° 48201C0945 L F.LR.M. J 48201C0945L PE M.A., ° d 'a ° ° ° PROPOSED cc: I DETENTION POND to 48201C 945 L ° ° ° a (RE: CIVIL DWGS.) UNDERGROUNCy b .'5._0": - .. ;. .5,2 ° d ° m\ e ° a 0 ELECT. SERV/C`E ° ° ,a ° d e IO to FROM METER TO P.P. o '-0' . 434-1 d 0" 32'-0" (3 SPACES) fg'_0" 35'-0" 20'-Q;a o HMAINP? SEj'ER� ', a .® °. ° ° ° d- ® ° d ¢ O d ° d N I O Z d� i tt ° " a r!J Z co ° d° LL W I ' PROPOSED SANK SEWER �, o ° SAMPLE WELLS a ° .d ° U i PROPOSED RPZ BACKFLO ° e : ° \ ° 14e-07 CZ9 a ° ° > d O rr d 2 ° I PHASE2 Pf30POSED METAL ° d ° A° °. BUILDING "B" ° 175W.METAL HALIDE W q 12,000 S.F. ° ° - ______-/ PACK W/PHOT ((AUTO SHOP) ° d6 a d.. '° e a �„ 4'-11/16" d ° 20.50 F.F. ° . °. a° d Q ? 4 4t TR WELL ® •. ,o .: °a a ti Q: ry °° ve :d ° a °, °: . d .W 3 N '.c•5 .d v °' ..d CD ° eI d LIGHT--=e vi ry ((}) (2/ ` 55'-0" rn 151'-0" W W k J 3 r/ rh9 son!!ary h \..Elm r4'--( \ serer Ml/ ¢ WEST MADISSONOr N Rm I9.04 3 STREET PROPOSED DETENTION POND \ I ¢ Z (ABANDONED R.O.W.) - - (RE. CIVIL. DWGS.) 4'-0 1116'+. ¢ "x o --- 10'B.L. SETBACK 1 t++ N +n9 +�' 49 -- + NEW 6' IG HAIN LINK FENCE + _ O WEST 296.00' Pp Nhe M ke i . BLOCK 653 GENERAL SITE NOTES PROJECT SITE 1. ALL CONCRETE PAVING AREAS SHALL HAVE 3000 PSI CONCRETE OVER A STABILIZED SUBGRADE 6" DEEP WITH APPROX. 6 PERCENT LIME, CONPACT 95 PERCENT PROCTOR DENSITY. 2. ALL PROPOSED CONCRETE SIDEWALKS AND RAMPS SHALL BE 4" THICK, 3000 PSI m " a CONCRETE REINFORCED WITH # 3 RODS AT 15" O. C.E.W. 3. CONTRACTOR SHALL PROVIDE 4"WIDE PARKING STRIPES, PARKING SYMBOLS AND '° '2 wearaours cut srw SIGNS AS PER PLAN. 4. ALL PROPOSED LANDSCAPING SHALL BE FURNISHED AND INSTALLED BY THE N ESt OWNER. 5. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL PIPE BOLLARDS AS PER Ma Iso StPLAN6. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL 3"PVC-40 SLEEVES AS 11st REQUIRED BY THE LANDSCAPE AND IRRIGATION CONTRACTOR. 7. PROVIDE 5"THICK CONCRETE PAD RENFORCED WITH # 3 RODS AT 15"O.C.E. W. FOR CONDENSING UNIT. Am _EA.A/C 8. PROVIDE 1,470 L.F. t OF 6'HIGH CHAIN LINK FENCE WITH BARBWIRE ON TOP AT L, PROPERTY LINE TO SURROUND ENTIRE PROPERTY. PROVIDE SWING GA TES AT EACH FT en er DRIVEWAY. V N ^ A5t ` y a LANDSCAPE NOTES West e 1. ALL PROPOSED LANDSCAPING SHALL BE INSTALLED ACCORDING TO CITY WC y t C OF LA PORTE DIVISION 4. FENCING AND LANDSCAPING REQUIREMENTS. y 2. GRASS, GROUND COVER, FLOWERING AND NONFLOWERING PLANT, SHRUBS AND w D St o TREES, WOOD, TIMBER, STONE FOUNTAINS, AND PONDS MAY BE USED FOR REQUIRED LANDSCAPING. 3. REQUIRED LANDSCAPING MUST BE MAINTAINED BY THE PROPERTY OWNER AND/OR OCCUPANT. 3. ALL PROPOSED TREES AND SHRUBS SHALL BE PLANTED WITH MIN. 3" LAYER OF MULCH. VICINITY MAP 4. REQUIRED TREES AS SHOWN ON SITE PLAN, PLANTED NOT GREATER THAN 20'-0" O.C. TREES TO BE EQUAL TO OR GREATER THAN 2" MIN. CALIPER AS MEASURED 6" ABOVE Z KEYMAP # 54OW ROOT COLLAR. 5. SHRUBS SHALL BE MAINTAINED AT HEIGHT OF NO MORE THAN 36"AND NO LESS THAN 18". MINIMUM CITY OF LA PORTE CONSTRUCTION LEGEND LANDSCAPE REQUIREMENTS PROPOSED BUILDING PER SEC. 106-800 (1) TOTAL DEVELOPED SITE AREA 14ZOSO S.F. PROPOSED 4"THICK CONC. SIDEWALKS -(2) ROOFED OVER IMPROVEMENTS 24,000 S.F. REINF W/#3 RODS @ 15" O.C.E.W (3) REMAINING DEVELOPED SITE AREA 118,080 S.F. PROPOSED 6" THICK CONC. PAVING RE1NF. W/ NOTE: TOTAL PARKING SPACES 30110 = 3 PARKING TREES #4 RODS @ 15" O.C.E.W PARKING TREES MUST BE PLANTED IN PLANTERS AT A MINIMUN AREA OF 135 S.F. AND MUST BE WITHING THE PARKING AREA IN ORDER TO BREAKUP THE MARS OF PARKING. PROPOSED 8" THICK CONC. PAVING REINF. W/ #5 RODS @ 12" O. C.E. W. PER SEC. 106-443 MINIMUM LANDSCAPING REQUIRED LI = 7.5 % 118,080 S.F. x 7.5 % = 8, 856 S.F. MINIMUM LANDSCAPED AREA REQUIRED CONSTRUCTION KEY 70,329 S.F. LANDSCAPED AREA PROVIDED 99,456 S.F. 70 %MAX LANDSCOPE IN WATERLINE 38 LIVE OAK 133 INDIAN HAWTHORN SHRUBS SS SANITARY SEWER LINE LANDSCAPE KEY E ELECTRIC CONDUIT. ABANDONED R.O.W. FRONT ELEVATION FLOOR PLAN DUMPSTER PLi A1.0 SCALE.,1/4"=1'-0" MASTER SITE PLAN z SCALE:1"=30'-0" EXISTING TREES TO BE REMOVED PROPOSED LIVE OAK TREE (8' HIGH MIN.) - 2 1/2" MIN. CALIPER PROPOSED INDIAN HAWTHORNE SHRUBS (18" TO PROJECT DATA U PROPOSED BUILDING A"- PHASEI = 1$000 s.f. O PROPOSED BUILDING "B"- PHASE 2 TOTAL COVERED AREA = 12000 s.f. = 24,000 s.f. PROP. SIDEWALK BLDG. A"- PHASE 1 = 376 s.f. PROP. SIDEWALK BLDG. "B"- PHASE 2 = 376 s.f. TOTAL SIDEWALK = 752 s.f. PROP. TRUCK WELL BLDG. A" - PHASE 1 = 1,375 s.f ,,,�( PROP. TRUCK WELL BLDG "S" - PHASE 2 = 1,375 s.(. W TOTAL TRUCK WELL = 2,750 s.f. Z TOTAL PROP. PAVING = 44,249 s.f. TOTAL PROP. LANDSCAPING = 70,329 s.f. W SUMMARY TOTAL COVERED AREA = 24,000 s.f. ( 1 TOTAL SIDEWALK = 752 s.f. �•/ TOTAL TRUCK WELL = 2,750 s.ff.. z TOTAL PROP. PAVING = 44,249 s. TOTAL PROP LANDSCAPING = 70,329 s.f. O TOTAL DEVELOPED AREA = 14ZO80 s.f. Z ZONING > CLASSIFICATION: LIGHT INDUSTRIAL (LI) J NAICS#: AUTO SHOP BUILDING MINIMUM CITY OF LA PORTE PARKING REQUIREMENTS PER ARTICLE Vl, SEC. 106-834 AUTO SHOP 'A" 12,000 S.F. AUTO SHOP "B" 12,000 S.F. TOTALFLOORAREA 24,000 S.F. FLOOR AREA (EXTERIOR FLOOR AREA - 159Q = 20,400 S.F. aca ccr. Io6-ego MINIMUM PARKING SPACES 4 TOTAL MINIMUM PARKING SPACES REQ 4 TOTAL PARKING SPACES PROVIDED 30 IMPORTANT NOTES 1, THEAMOUNT OF PARKING REQUIRED WILL BE REVIEWED AT THE TIME OF ISSUANCE OF A ZONING PERMIT. ADDITIONAL PARKING MAYBE REQUIRED BASED ON THE USE OF THE SITE. 2. AUTOMATIC IRRIGATIONS SYSTEM IS REQUIRED FOR ALL REQUIRED LANSCAPING. 3. ANY OUTDOOR STORAGE MUST BE SCREENED FROM VIEW FROM ANY PUBLIC RIGHT-OF-WAY. 4. CONTRACTOR TO INSTALL PROPOSED FIRE HYDRANTS. 5. EXPANSION JOINT IS REQUIRED AT THE PROPERTY LINE FOR THE PROPOSED DRIVEWAY. H L O � N i 00 0 [ N Z r r j+ 3 to X 0 X N O NCF 0 3 O O N _ O p 00 Z = c0 � O I O S 36" HIGH) @ 36" O.C. DISTRIBUTED THROUGHOUT a LANDSCAPED AREA - 5 GALLON MIN. EL 8"x4"x 16"SMOOTH ,�p��•OF•rF"I.9 J 0 0 WOLMANIZED Q Q _ FACED CMU -PAINTED PINE GATES * . SW #6106 KILIM BEIGE * i ............ * W ORLANDO J. TERAN W Edm U.) PIPE COL. GATE0� z F- SUPPORT F 'G. S T ER • �2 h- SSfON W W (n m CMU WALL `c7 W >. W E` i ox . i 8"x 8"x 16" SPLIT a J` W O vJ J O FACED CMU - PAINTED '' ^^ '' v^^ W U SW #6106 KILIM BEIGE T T r k O iC~fl_ .L� L SIDE ELEVATION W O Z Z ^0^ � 11 FLOOD STATEMENT N C This tract is in Flood Zone AE and FlOodway and It is within the 100- year Flood Plain and Floodway _ according to the FEMA Map # 48201C0945L, Dated June 18, 2007. W 7 CITY APPROVING AUTHORITY CERTIFICATE Q This is to certify that the City of La Porte, Texas has approved This site plan and devolopmont in conformance with the Ordinances of the Cl f La port . 1 By. Director, Planning Departmm • REVISIONS J -71 DATE DESCRIPTION O e SITE PLAN ACCURACY CERTIFICATE 1Q 07-21-15 PERMIT REV'S r2 I. Orlando Term _ , am registered under the laws of the State of Texas to practice ¢ the profession otengineering and herrby cert'rty that above site plan is true and O correct; and that all bearings, distances, angles, cuNe radiuses, and central angles are accurately shown On the site plan. This certificate does not apply to boundry of the site. "t"- (Print Name) _ �aM SCALE g ✓ATIONS DETAIL zzjN0,,, p� = 30'-0" IL Texas Registration No. 57207 ® PROJECT NO. % ®� ® a dam - SHEET TITLE Met Own 2 LEGAL LOT 1 THRU 3Z BLOCK 544, 3.261 ACRES, TRS B C 8 D (ABANDONED ROW), RECORDER IN VOLUME 58, PAGE 460 OF THE DEED RECORDS OF HARRIS COUNTY, TEXAS. O O SHEEP NO F A1.0 W m i ti DATE: JUNE 02, 2014 O