Loading...
HomeMy WebLinkAboutFIRE TRAINING FACILITY TRUCK BAY & STORAGE FACILITY RESTROOM1,9 6a A LEGEND $ SWITCH 120V/20A GRND TYP FD FLOOR DRAIN EF EXHAUST FAN —10, 201 201 dlu w I --a-d CLEIZIN151 Icx-N ('2?P11C4Z) COVERED AREA W/ LIGHTING CENTER LINE OF PROPOSED DITCH W/ MINIMUM 3 TO 1 SIDE SLOPES BY C L EXIST. FENCE LINE \/ /'90-0 STORAGE MEZZANINE ABOVE RESTROOMS DESIGNED FOR 110 lbs/SF 19,60 CZZIN6' 1cXN KI-111panz) I > I Q��Kl ROOF LINE 7,5/ Ix X Mr., C-� CD CD L'_j TYPICAL WALL DETAIL "B" 2" WATER METER PROVIDED BY CLP Lu" 2" WATER TAP PROVIDED BY CLP PROP. 4" SAN. SWR. S_ ATER FAUCET ACCUUM BREAKER /9 6'0 C/-) ZZ_Z_C1.?1CXZ 90/r, (Zl- rIS71NC) I 51 4N 5XI, F § bl? 5 ?' 5Z 0/ DLf - z 9/ 1 / CZ / D --w-__­� /9 16' BENCH MARK ff/0 LA �-UNIL �iUKVLY MAr, ANLA '16, FU. 1, HIZ-Ui. T.B.M. "X" ON NORTH RIM OF MANHOLE @ SOUTHWEST CORNER 23RD STREET AND "C" STREET, ELEVATION 20.63. (1978 DATUM) CONSTRUCTION NOTES: 1.) CONCRETE SHALL BE CLASS "A", 3000 PSI CONC. @ 28 DAYS 2.) CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE CONSTRUCTION WATER. CITY OF LA PORTE CONSTRUCTION WATER METERS ONLY SHALL BE USED TO OBTAIN CONST— RUCTION WATER. METERS MAY BE OBTAINED AT LA PORTE CITY HALL. 3.) CITY OF LA PORTE PLANNING DEPARTMENT SHALL BE NOTIFIED 48 HOURS PRIOR TO CONSTRUCTION. 4.) ANY EXCESS SOIL SHALL BE SPREAD ON SITE. 5.) CONTRACTOR SHALL CONTACT THE UTILITY COORDINATING COMMITTEE FOR THE HOUSTON METROPOLITAN AREA 48 HOURS PRIOR TO CONSTRUCTION @ 223-4567. 6.) LIME STABILIZED SUBGRADE (6%), THE USE OF DEHYDRATED LIME IS NOT ACCEPT— ABLE FOR SUBGRADE STABILIZATION BY CLP. 7.) SUBGRADE SHALL BE PROOF ROLLED PRIOR TO STABILIZATION. ALL SOFT AREAS SHALL BE EXCAVATED TO SUITABLE SOIL, THEN BACKFILLED AND COMPACTED WITH LIFTS NO GREATER THAN 8" BY CLP. 8.) CONSTRUCTION STAKING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 9.) CONCRETE SHALL HAVE A BROOM FINISH UNLESS OTHERWISE NOTED. 10.) GRADE BEAMS SHALL BE INSTALLED WITH 3" CARTON FORMS IF USING A DRILL FOOTING DESIGN. 11.) CAST IRON TRENCH DRAIN SHALL BE A NEENAH #R-4999—DX (TYPE P GRATE OR APPROVED EQUAL. 12.) BUILDING TO HAVE A 12' EAVE HEIGHT WITH A 1 TO 12 SLOPE. 13.) THE COVERD AREA STRUCTURAL MEMBERS Z—PURLINS AND SUPPORTS SHALL BE PAINTED WITH A TWO PART EPDXY PAINT. 14.) REMOVE A MINNIMUM TOP 6" OF EXISTING SOIL / FILL SHALL BE SELECT FILL WITH A PLASTIC INDEX RANGING FROM 7 TO 20 AND COMPACTED TO A 95% MAXIMUM DRY DENSITY BY CLP. 15.) SANITARY SEWER UNDER PAVEMENT SHALL BE CEMENT SAND BACKFILL UP TO BOTTOM OF CONCRETE BY CLP. 16.) A/C UNIT FOR RESTROOMS WILL BE A 2 TON UNIT W/ A COMPRESSOR UNIT ON THE EAST SIDE OF THE STRUCTURE AND HAVE AN EVAPORATOR AND AN AIR MOVER INSTALLED HORIZONTALLY ABOVE THE REST ROOMS WITH FLEXIBLE DUCT FOR EACH RESTROOM. 17.) CEILING FANS SHALL BE 56" MOISTURE RESISTANT W/ A 265 RPM MOTOR (DAYTON #4C771 OR EQUAL). SWITCHES ARE TO BE INSTALLED INSIDE STRUCTURE NEAR AN ENTRY DOOR. 18.) INSIDE LIGHTING SHALL BE T96T12HO SHEILDED FIXTURES W/ APPERTURES (120 VOLT) OR EQUAL. 19.) OUTSIDE LIGHTING UNDER CANOPY SHALL BE T96T12HO SHEILDED FIXTURES NON APERTURES (120 VOLT) OR EQUAL. 20.) FLOOR DRAINS IN RESTROOMS SHALL BE EQUIPPED WITH TRAP PRIMERS. 21.) PROVIDE VACCUUM BREAKERS ON ALL HOSE BIBS. 22.) PROVIDE EXIT LIGHTS WITH BATTERY BACK UP. LIGHTING AT ALL EXIT DOORS. 23.) ANY PENETRATIONS THROUGH THE FIRE RATED WALL SHALL BE SEALED OFF WITH APPROVED FIRE RATED CAULKING. 24.) SCORE SIDEWALKS AT 4' INTERVALS 0 W 04 7� 0) E Q) 0 Q) 0 rL V) CATY (O"T LA PORTE. FIRE TRA7NiNG FACILITY DRAWNBY:SPARKS DESIGN: MCPHAIL JAPPROVED: FRED FILE NO.: 95-2201 4; SCALE: I"= 5' DATE: 5/96 TOPO: H-12 ISHEET 3 OF4