HomeMy WebLinkAboutFIVE POINTS PLAZA (3)�1
-4
pp-
' IBM
q
F w
_
F_
F_
F_
F_
)IN OF CONNIE N FO RIGATION
S ALL BE TREAM 2'
�1 ATION WATER METER
Y STRAINER
DOUBLE CHECK VA VE
TH CAPPED TEST CO KS.
"\N"
\14 :�eql
(P
(P
CONTROLLER: WEATHERMATIC SL4800 SERIES MODEL SL4800 (24
STATIONS) WITH SLW WEATHER STATION, SLRC REMOTE CONTROL,
AND 995 RAIN SENSE RAIN SENSOR, COORDINATE 120AC TO A
15AMP CIRCUIT AT ELECTRICAL PANEL WITH ELECTRICAL
CONTRACTOR. CONTROLLER SHALL BE WALLL MOUNTED INSIDE
BUILDING. SLW WEATHER STATION, AND 995 RAIN SENSOR SHALL BE
MOUNTED OUTSIDE ON BUILDING ROOF (REF. IRRIGATION DETAIL,
E- [D
VERIFIY LOCATION WITH CITY MANAGE R
NOTE: SMART CONTROLLERS HAVE BUILT IN FREEZE AND RAIN
SENSORS
IRRIGATION LEGEND
HUNTER ROTOR HEAD
(D
PGP SERIES NOZZLE NO. 10 FULL AND HALF
CIRCLE 6 GPM 9 40 PSI, 40 FT.
RAINBIRD POP—UP LOW ANGLE SHRUB SPRAY
MPR SERIES NO. 8 FULL, HALF, & QUARTER ON A
1812—SAM—PRS BODY.
IRAINBIRD
POP —UP LOW ANGLE SHRUB SPRAY
MPR SERIES NO. 12 FULL, HALF, & QUARTER ON A
1812—SAM—PRS BODY.
RAINBIRD POP—UP LOW ANGLE SHRUB SPRAY
MPR SERIES NO. 8 FULL, HALF, & QUARTER ON A
1804—SAM—PRS BODY.
RAINBIRD POP—UP LAWN SPRAY
Ah
A
MPR SERIES NO. 12 FULL, HALF, & QUARTER ON A
1804—SAM—PRS BODY.
RAINBIRD POP—UP LAWN SPRAY
6
MPR SERIES NO. 15 FULL, HALF, & QUARTER ON A
1804—SAM—PRS BODY.
FEBCO Y STRAINER NO. 650A
RAINBIRD QUICK COUPLER VALVE /33DLRC 314" AND BALL VALVE.
(KITH PURPLE NON POTABLE COVER)
RAINBIRD BUBBLER 1400 SERIES NOZZLE NO. 1401 ON
112" FLEXIBLE PVC RISER. (REF DETAIL)
RAINBIRD PE13 SERIES KITH FLOW CONTROL,
ELECTRIC REMOTE CONTROL VALVE AND BALL VALVE.
SCHEDULE 40 PVC MAINLINE
CLASS 200 PVC LATERAL LINE, EXCEPT 112 INCH
DIAMETER SHALL BE CLASS 315. NOTE: ALL DIRECTLY
BURIED LINE BENEATH PAVING SHALL BE SCHEDULE 40 PVC
GPM THROUGH VALVE
VALVE SEQUENCING NUMBER
SIZE OF VAL VE
MANUAL GATE VALVE —LINE SIZE
ELECTRIC CONTROLLER
MANUFACTURE AND MODEL AS SHOWN ON PLAN
6" SCHEDULE 40 PVC SLEEVE
2" IRRIGATION WATER METER & TAPING SLEEVE
(BY GENERAL CONTRACTOR)
FEBCO DOUBLE CHECK VALVE:
2- #805Y IN FLUSH CONCRETE VALVE BOX(BELOW GRADE)
NETAFIM—TECHINE FLUSH VALVE
NETAFILM TECHLINE CV DRIP LINE DRIPPER SPACING 12"
0.90 OPH NO. TLCV-12 KITH 12" LINE SPACING.
RAINBIRD J14- CONTROL ZONE KIT
MODEL NUMBER XCZ-075—PRF. .2 GPM — 5 GPM
(REF. DETAIL)
Or
RAINBIRD I" CONTROL ZONE KIT
MODEL NUMBER XCZ-100-8—COM JGPM-20GPM
(REF DETAIL)
1A VALVE SEQUENCING NUMBER
-5 GPM THROUGH VALVE
in SIZE OF VAL VE
255 TECHLINE LENGTH
RRIGATION
NOTES
1. LINE LAYOUT IS DIAGRAMMA TIC —ADJUST HEAD AND LINE
LOCATIONS ON SITE TO ACCOMMODATE EXISTING JOB
CONDITIONS AND TO ACHIEVE COMPLETE COVERAGE.
2. ALL MAIN LINE PIPING SHALL BE BURIED TO HA VE A MINIMUM
COVER OF 18". ALL LATERAL PIPING DOWNSTREAM OF THE
MAIN LINE SHALL BURIED TO HAVE A MINIMUM COVER OF 12".
3. ALL MAINS ARE TO DRAIN TO LOW POINTS AT A MINIMUM ONE
HALF(112%) PERCENT SLOPE. AT LOW POINTS, INSTALL GATE VALVE
TO FACILITATE DRAINAGE OF SYSTEM DURING FREEZING
TEMPERATURES
4. CONTRACTOR SHALL INSTALL AUTOMATIC DRAIN VALVES AT LOW
POINTS IN THE IRRIGATION LINES AS REQUIRED TO PREVENT
FREEZE DAMAGE.
5. ALL VALVE BOXES SHALL BE BLACK IN COLOR(BODY AND LID).
SIZES SHALL BE TEN(10") INCHES BY FOURTEEN(14-) INCHES
(RECTANGULAR) FOR REMOTE CONTROL VALVES AND NINE(9")
INCHES(ROUND) FOR GATE AND QUICK COUPLER VALVES.
6. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO SYSTEM
LAYOUT IN FIELD TO INSURE POSITIVE DRAINAGE OF LATERAL
LINES AND MAIN LINES.
7 CONTRACTOR SHALL NOTIFY THE LANDSCAPE ARCHITECT, IF THE
STATIC PRESSURE IS LESS THAN THE DESIGN STATIC PRESSURE OF
65 PSI. PRESSURE REGULATION AT THE SOURCE SHALL BE REQUIRED
IF PRESSURE IS GREATER THAN 75 PSI.
8. ALL WIRING FROM THE IRRIGATION CONTROLLER TO THE REMOTE
CONTROL VALVES SHALL BE UF-1411 DIRECT BURIAL CABLE. ALL
WRE SPLICES SHALL BE MADE IN VALVE BOXES ONLY USING
RAINBIRD SNAP—TITE CONNECTORS AND SEALANT PROVIDE
SLEEVES FOR WIRE UNDER PAVED AREAS AS REQUIRED.
9. ALL IRRIGA77ON INSTALLATION SHALL CONFORM TO THE LOCAL
CODES AND REGULATIONS
10. IRRIGATION SYSTEM SHALL BE INSTALLED AND FULLY OPERATIONAL
BEFORE LANDSCAPING INSTALLATION.
ii. IRRYGA77ON HEADS SHALL BE PLACED AND ADJUSTED SO AS NOT TO
SPRAY ON THE BUILDING.
12. IRRIGATION HEADS SHALL BE PLACED AND SIZED SO AS NOT TO BE
SUSCEPTIBLE TO DAMAGE BY AUTOMOBILE OVERHANGS.
13. IRRIGATION CONTRACTOR SHALL PLACE ADJUSTABLE
ARC NOZZLES IN PLACE OF FIXED ARC NOZZLE AS NEEDED
TO ELIMINATE OVERSPRAY ON TO PAVEMENT
C-A
0 5 1.0 20
SCALE IN FEET (APPROX.)
0
..........................
GRANT A. GUIDRY
..............................
Ims
URS GROUP INC.
9W1 WESTHEIMER
SUITE 101
HOUSTON, TEXAS 77042
PH: 713.914.6699
FAX 713.789.8404
46
W X
0
w
Co NC4
C404
M M
Z
w w
d
w z
00
U)
z w
0 0
W
> LL
0
�T . . . 1��NPILE
6 March, 2009
URS Project number 25009951
Date 6 March, 2009
Drawn by scb
Checked by scb
LANDSCAPE
IRRIGATION
PLAN
SHEET1 OF 2
L2-01
AS NOTED