Loading...
HomeMy WebLinkAbout11-2202 LP DOT WEIGH STATION (SH 146 N)SITE PLAN NOTES 1. ALL DIMENSIONS ARE TAKEN TO FACE OF CURB OR BUILDING UNLESS NOTE: OTHERWISE NOTED. 2. CONTRACTOR SHALL VERIFY DIMENSIONS AND NOTIFY ENGINEER OF EXPANSION JOINTS TO BE EVERY 40 FEET. ANY DISCREPANCIES. 3. USE DIMENSIONAL INFORMATION GIVEN. DO NOT SCALE DRAWINGS. CONTRAC11ON JOINTS TO BE EVERY 40 FEET. 4. CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND PROTECT ALL ALTERNATE EXPANSION JOINT AND CONTRAC11ON EXISTING SITE IMPROVEMENTS AND UTILITIES DURING CONSTRUCTION JOINT EVERY 20 FEET. OPERATIONS. 5. ALL WALKWAYS LEADING TO ENTRANCES ARE TO BE CENTERED ON DOORWAYS UNLESS OTHERWISE NOTED. 6. PAVEMENT CONTRACTOR SHALL BLEND NEW PAVEMENT TO EXISTING CONDITIONS. PAVEMENTS SHALL ALIGN BOTH VERTICALLY AND HORIZONTALLY. PONDING AT JOINTS WILL NOT BE ACCEPTABLE. 7. PROVIDE MINIMUM 1/8" PER FOOT CROSS SLOPE IN DIRECTION OF SURFACE DRAINAGE ON ALL WALKWAYS. 8. WHERE NEW CONCRETE PAVEMENT MEETS EXISTING CONCRETE OR CATC14 VERTICAL SURFACES PROVIDE 1/2" EXPANSION JOINT. WHERE NEW BASIN CONCRETE PAVEMENT MEETS EXISTING ASPHALT SAW CUT EDGE OF 20.40 MATLIM =1 �al I ..A 4 ASPHALT AND BUTT NEW PAVEMENT TIGHT. SCORING JOINTS SHALL A 4 4. MATCH EXISTING CONDITION WHERE NEW CONCRETE PAVEMENT 9:54� --------- NORTH REPLACES EXISTING OR ABUTS EXISTING CONCRETE PAVEMENT. A 4 4 9. FINISH ON CONCRETE SHALL BE PERPENDICULAR TO TRAFFIC FLOW. 10.WHERE NEW ASPHALT PAVEMENT MEETS EXISTING ASPHALT, SAW CUT EXISTING ASPHALT. ALL NEW PAVEMENT SHALL MEET EXISTING ,A ...... �-xqg� 0 4A A A' N.;A.*--BbUN ME SH 146 FEEDER ROAD L %A - ----- UIST. C6NC.'R6A6 wl�fibURB GUTTER 14 .... ........ 4- 4 T - -------- i FLUSH. 20.30 :A '4 .4 4. 1. '4 6 , ' � ' * ' ' A 4 11.PARKING LOT LINES AND TRAFFIC CONTROL MARKINGS SHALL BE 2066 A PAINTED ON PAVEMENT WITH MINIMUM 4" WIDE LINES OR AS SHOWN 0.69 X20. ;R0.90 A X19.76 X19486 ON PLANS. t4 12.ALL COMPLACT SPACES AND AISLES SHALL BE SIGNED OR MARKED A 19 TG 20.58- ' P 4 20.38 40 "SMALL CAR ONLY". 4 X26, A : 4 !�- Oi - TG = 20.94-,p X20.47 TG 20.91 13. PROVIDE EXPANSION JOINT MATERIAL AT ALL LOCATIONS WHERE 4, A" 1q- X20.21 CURB AND CUTTER ABUTS OR IS ADJACENT TO WALLS. 4 4 A A MEDIAN �b .06 14.AUTOMATIC UNDERGROUND IRRIGATION SYSTEM MUST BE PROVIDED. �4- CONTRACTOR TO PROVIDE SLEEVING FOR UNDERGROUND IRRIGATION SYSTEM AND COORDINATE WITH IRRIGATION PLAN. TG = 20.71 15.ALL HANDICAP PARKING SPACES SHALL HAVE SIGNS AS INDICATED 19.96 "' 6 .4 19.92 1 x x� x A' n-37 ON THE PLANS AND AS PER DETAILS. >0966 4' TG = 20.94 0.76 F71 A TG 20.91 A 19.76 X20.84 DIRT & MASS HATCHED AREA AS SHOWN ON PLANS 4 4 >09. 4 >00.97 TO NOT HAVE ANY TRANSVERSE OR TG = 20.84 0 LONGITUDINAL SLOPE. HOLD ELEVATION >2 1 -Of, x .11 x2l. Cq /Z/ 0 A� A >09j A 19.37 0<20.96 A TG = 1 200.13 AS SHOWN ON PLANS FOR 20 FEET AND 20.94 20.91 THE14 SLOPE PAVEMENT TO MIDDLE. 4 1.4 r --�80' 4. A >09. 0<21.06 >00.98 T19.72.* x20.O8 Z x2l.07 ': . X,gz I 120.914 < 19. TG = 20.72 >00.94 4 11 -' . 0 4 .:A, 4 : 4 I.A. �-p 'A 19-74- - 0 >09. . 1 .1 - X20.74 2 X2( 1 x20.92 S.H. 146 OVER-P SS .111 2--A. .1 .-4 19.24 TG 20.94-� >00.87 TG 20.9 MATCH EXIST. 0 4 9. >0 E 0<20.80 ..0 , 4 >60.79 X20.96 A' II IMW �q 12, 19.37 11'4 A 19.62 x20.67 >09.7 DIRT GRASS A 0<20.82 >00.58 -x2n X x2 8 x20.74 4 A A IM4 A TG 20.60 19.71 X20 �78 A - CONQ TG 20.9 TG 20.91 MEDIAN A. MEDIAN A A: 0. X20. x20.50 PAMNG NOTE: . A 19.96 9.79 T I HOT POURED RU50ER JOINT SEALING COMPOUND _)",24" NO.5 SMOOTH ASPHAL' COATED DOWELS T/2 5 BARS ON 18" CTRS. LOOSE W TRANSVERSE CONTRACTION JOINT Ll- NU. 0 Z5MUU*T )OWEL 5" ASPHALT COATING HOT POURED RU88ER JOINT SEALING COMPOUND -J N26 GAUGE STEEL TUBE DOWEL SUPP ORT-`/ AS APPROVED BY ENGINEER EXPANSION JOINT FILLER REDWOOD OR CYPRESS BOARD TRANSVERSE EXPANSION JOINT BACK OF CURB TO BACK OF VARIABLE 0 TO 2`MAX. SPACING AT 2'-01' CTRS. SPACING DIAGRAM FOR DOWELS AT EXPANSION JOINTS V%6 t F-r%V11'1%J IV Or- 1U MICK CONCRE-Ir- Vy/ #5 REBAR ON 18" CENTERS W/ 12" LIME STABILIZED 20.12 0 �2 .95 X2 .04 �- 1 BASE (8% BY WEIGHT) 0. -4- - X20.00 X19.85 A A. 4 4 'A A. . . ...... .. 7, A 4 . ............ I ...... 6..* ..................... 4- .............. . ... S. BOUND LANE EXIST. SH 146 FEEDER ROAD ........... A ...6 .... ...... "4,9. 4. .. ... - CONC. ROAD WITH CURB & GUTTER % ........ 4 I am :A - CURB INLET FLOOD STATEMENT THE PROJECT IS LOCATED ENTIRELY WITHIN FLOOD NOTES: ZONE "X" PER FIRM MAP 48201CO945, SUFFIX 1. THE COORDINATES SHOWN HEREON ARE TEXAS SOUTH "L" DATED JUNE 18, 2007 CENTRAL ZONE NO. 4204 STATE PLANE GRID COORDINATES NAVD 1988, 2001 ADJUSTMENT (NAD83) AND MAY BE BROUGHT TO SURFACE BY APPLYING THE FOLLOWING COMBINED SCALE 0.99987483. )N VOLUME STATEMEN SITE PLAN ACCURACY CER11FICATE CITY APPROVING AUTHORITY CERTIFICATE DETENTION IS NOT REQUIRED ON THIS PROJECT DUE TO ULTIMATE 1, RODNEY L. SLATON, P.E., am registered under the laws of the THIS IS TO CERTIFY THAT THE CITY OF LA PORTE HAS APPROVED THIS SITE PLAN FOR SITE IM CONDITIONS FOR THE PROPOSED 100-YEAR CONVEYANCE CAPACITY State of Texas to practice the profession of engineering and hereby certify IN CONFORMANCE WITH THE ORDINANCES OF THE CITY OF LA PORTE. FOR F 101-00-00 BEING MET PER A STUDY PERFORMED BY LANDEV that the above site plan Is true and correct, and that all bearings, distances, ENGINEERS DATED SEPTEMBER, 1987 AND FULLY IMPLEM,ENTED BY angles, curves, radii, and central angles are accurately shown on the site plan. HARRIS COUNTY FLOOD CONTROL FOR THIS REACH OF F 101-00-00. PROPOSED DEVELOPMENT IS WITHIN THE STUDY*S DRAINAGE AREA. BY. A&W DIRECTOR, PLANNING DEPARTMENT BY: Rodney L. STaton, P.E. Texas Registration No. 90298 S2612613iftla I2S2J1nQ 1. LIGHTPOLES OR SIGN POLES ARE NOTALLOWED IN PARK JNG OR TYPE OF DEVELOPMENT Floodplain RM No.: 060035 DRIVEWAY PAVEMENT AREAS. COORDINATE LOCATIONS WITH WEIGH STATION FOR TRUCKS B -BARBOU S-Cul 0- 'BL Northing: 13813547.61 Easting: 3227286.63 LANDSCAPE PLAN. ZQNING Elevation: 20.06 2001 Adjustment 2. CONTRACTORTO PROVIDE CONDUITS FOR SITE LIGHTING. N/A Texas South Central / NAD 83 3. PIERS FOR LIGHT POLES SHALL NOT BE ABOVE CURB. ()MER SIT 4. ALL LIGHT POLES WILL BE A MINIMUMTHREE (3) FEETBEHIND ANY CITY OF LA PORTE Description: Floodplain Reference Mark Number 060035 CURB. 604 W. FAIRMONT is a BRASS DISC Stamped RM 060035 on bridge at 5. CONTRACTOR MUST OBTAIN, READ, AND COMPLY WITH ALL LA FORM TIEXAS 77571 4-ST 'T West Barbours Cut and F216-00-00 located on downstream GEOTECHINICAL RECOMMENDATIONS CONTAINED INTFIE FIR I concrete walk on the southeast corner of the bridge in KeyMcp GEOTECHNICAL REPORT PREPARED BYTERRACON. -FR:S! 540W in the Galveston Bay Watershed near stream F 216-00-00 6. ALL CURB AND GUTTER LOCATED AT ACCESSIBLE PARKING SPACES ELEV. 20.06 Feet NAVD 1988, 2001 Adjusted. SHALL BE SPILL ONLY. 7. ALL LIGHTING IN THE PARKING LOT SHALL BE HOODED AND SHALL r NOT BE VISIBLE FROM THE NEIGHBORING RESIDENCES IN COMPLIANCE W- DA WITH SEC71ON 106-521(c). 8. SEPARATE IRRIGATION AND SIGN PERMITS ARE REQUIRED FROM THE CITY. S I T 9. GENERAL CONTRACTOR IS RESPONSIBLE FOR MAKING SEWER TAP INTO EXISTING SS MANHOLE. CALL PUBLIC WORKS AT(281) 471-9650 BIR FOR INSPECTION. Jul-/ 10.OWNER/DEVELOPER SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF THE DRAINAGE DITCH AT THE REAR OF THE PROPERTY. 11.DRAINAGE, DETENTION, AND DRAINAGEWAY MAINTENANCE SHALL BE VICINITY MAP THE RESPONSIBILITY OF THE OWNERIDEVELOPER. AN' ip RODNEY L SIAT 90298 OF NIN.-A-0W010.)-hi 01 `JUNAL 7-'- T6he seallVip'pearing on this document was authorized by RODNEY L. SLATON P.E. 90298, on 3 -.T- I D- r CITY OF LA PORTE PLANNINC ENGINEER RODNEY L SLATON, P.E. 604 W. FAIRMONT LA PORTE, TEXAS 77571 OFFICE 281-470-5060\ E-MAIL slatonrOoportetx.gov CITY OF LA PORTE LA PORTE D.O.T. WEIGH STATION 607 N. HWY 146 CITY OF LA PORTE, TEXAS Working Point (at intersection of nominal I.D.) 211 Trimmed Edge of Pipe 6 a) E OL 0 — Z: CL 7 NOTE: All Cross Pipes, calculations, and dimensions are based on the pipe culverts mitered as shown in this detail. Alternate styles of mitered ends will require that appropriate adjustments be made to the values presented on this standard. #6 Anc SIDE ELEVATION OF TYPICAL xI -4 PIPE CULVERT MITER L3 YO 0 (Showing Corrugated Metal Pipe Culvert.) (Details at Concrete Pipe Culvert are similar.) L > 0 (D 0 0 L 04- a- U) W 4-'0 4- 00 L-- C.0 0 3�O E C 0 0) Q) 0 L III U) 4- 4- C 0 U) .- C1 U CPL 0) C C :3.-.- UJ CL C 4- a C4- in X 0 0 Q) (1) L 1­- L C 0 0 V) 4- 1­_ L C) Q) E > 0 X C V DI-_ 0 R i prop 0 L 'a ;IN 0 WJ0 W C C L a) 4- > 0 L :3 0 r- 0 (D U 4- a) Cross Pipe U).(O >,, L (Typ) — 10 C_ W L---- L 0 Y D L 'D ­0 C >11 U) 0 0 C C C +- 0o.- U) cl 4- U) L (n 0 a) 0 L 4- 0 L C C 0 4- 0 0 L U) U) L Q) +- Q) 0 E 0 X U) 3� D E Ld U) L :2 01:00 (D Z 0 4- < r _JF- L U 0) V) E 1­1 0 X4- 0 < F_ 0 N Toewo I I x 00 0 Flow L i ne I ISOMETRIC VIEW OF TYPICAL INSTALLATION Cross Pipe Length ,_92 (See Table),. Ql (See Table) 2 Cross Pipe Cross Pipe over over Inside Outside 15/1 ro If Dia Barrel Barrel Through Hole (Typ) PIPE W/ BOLTED ANCHOR 311 hor Bar Typ If (Typ) 41, 41, Typ TyP_J -- - — - — - — - — - — - — ----- Bend first Cross Pipe Anchor Bars as necessary to maintain 2" clear cover to Toewall edge of concrete Riprop PIPE W/ ANCHOR BARS �_ Cross P i pe - — Typ _> < 114 3" C\JJ1 C Top of Riprop Flow Line I it C. M. P. C L End of Invert :2 a) > for Concrete - c: Pipe Culvert Toewall 3" Min 12 11411 12 Overlap w/ C.M.P. oO B DETAIL A (Showing Invert with Corrugated Metal Pipe Culvert. Concrete P 1 pe Cu I Vert deto i I s are similar. Cross Pipes not shown fo clarity.) C `— Flow Line SECTION B-B (Cross P i Pes not shown f or c I or i ty. #6 Anchor Bar x l'-4" (T\/n) SECTION C-C CROSS PIPE LENGTHSr REQUIRED PIPE SIZES, & RIPRAP QUAMITIESO Nominal Cu I vert I. D. Conc R i prop (CY) 6 , Pipe Culvert SPO - G Single Barrel - Ql Multi- Barrel Q2 Conditions for use of' Cross Pipes Cross Pipe Size 1211 0. 6 911 N/A 2' -1" it- 91, 3 or more Pipe Culverts 311 Stcl (3. 500" 0. D.) 1511 0.7 111, N/A 2' - 511 2' - 2 1811 0. 8 If- 2 N/A 2t-10" 21- 811 21" 0.9 10- 411 N/A Y_ 211 31- 111 2411 0.9 If- 711 N/A 31- 6 if 31- 711 279, 1.0 11- 81, N/A 31.-1011 3t -11" 3 or more Pipe Culverts 3 1/2 " Stcl 30" 1.1 11-101, N/A 4'- 211 4'- 41, 1 2 or more Pipe Culverts 3311 1.2 1" -1 1 If 4'- 211 4t- 511 41- 811 All Pipe Culverts (4. 000t, 0. D. 3611 1.3 21- 111 4' - 511 4�_ 911 5' -lit All Pipe Culverts 41, Std (4.500" O.D.) 4211 1.5 2'- 411 4'-11" 5'- 511 51-1011 4811 1.7 2f- 7t, 5'- 511 ro' - Oil 6'- 71' 511 Stcl All Pipe Culverts (5.563" O.D.) 54" 2.0 31- oil 5/-11" 6'- 9 7' - 6 " 0011 r 2.2 3'- 3 " 61- 5" 7�_ 411 8 1- 3 " 6611 2.4 31- 3 " 6t-11" 71-1011 81- 91, 72" 2.7 - 4 '1 1 7'- 5" 8t- 511 91- 411 UKU�>ft> FIFL U IAILS (� Cross Pipe (flush #6 Reinforcing I with top of Riprop) Anchor Bar ---, L 1MI IS Of R i prop - — ?_ - - - - (to be included V-6" (Typ) with S.E.T. for Tangent to payment) widest portion of Pipe Culvert Riprop Pipe Culvert Pipe Culvert (C.M.P. or (C. M. P. or Concrete) Concrete) 2 " Min Clear Limits of Riprop (to be included with S.E.T. for payment) 5 SHOWING TYPICAL PIPE SHOWING CROSS PIPE CULVERT & RIPRAP WITH ANCHOR BAR 30 -611 2 J - Cross Pipes 2- 1 -01, -6 It Max Eq Spa at 2'-0" Max 6" Min I - (7) 1 171 f--- ss ripe %TIUS" top of Riprap) 'immed Edge of Pipe Culvert (� Cross Pipe Anchor Bo[tL./ I 3 1/2 D * a Cross Piple(DQ a a- 00 L 0 Top of Cross C a .0-? 0 () IZ 1 3 Pipe (D C < 891 411 F I ow 0 M 0 L i ne 1211 See DETAIL "A" SIDE ELEVATION OF CAST -IN -PLACE CONCRETE (Showing Concrete Pipe Culvert.) (Details at Corrugated Metal Pipe Culvert are similar.) 4" Min, -1 2" Mil -dl Anchor Toewo I I Pipe Culvert (C. M. P. or Concrete) — Q1 Y4" x 12" Bolt w/ Hex Nut & Washer (� Cross P i Pe (f I ush with top of Riprop) _fv�� I Center Anchor Bolt between Pipe Culverts Pipe Culvert I. D. (Nom i no I ) SHOWING CROSS PIPE WITH BOLTED ANCHO SECTION A -A __,-Q2 or QI I Pipe Culvert Spa - G (D The Proper installation of the first Cross Pipe is critical for vehicle safety. The top of the first Cross :Iipe must be placed at no more than 6" above the flow linE. QSize of Cross Pipes, except the first bottom pil:�, shall be as shown in the PIPE SIZE table. The first tDttom pipe shall be 3 V2" Standard Pipe (4" O.D.). The third Cross Pipe from the bottom of the Culvlzrt shall always be installed using a bolted connection. ore shall be taken to ensure that Riprop concrete does not flow into the Cross Pipe so as to permit disassembly of trlz bolted connection to allow cleanout access. At the Cortractor' s option, all other Cross Pipes may also be installed using the bolted connection details. Match Cross Slope as shown elsewhere in the plan3. Cross Slope of 6:1 or flatter is required for vehicle 31ofety. Riprop placed beyond the limits shown will be paid as Concrete Riprop in accordance with Item 432, "Ri)rap". Quantities shown are for one end of one reinforc�d Concrete Pipe Culvert. For multiple pipe culverts or for Corrugated Metal Pipe Culverts, quantities will need to be )djusted. Riprop quantities are for Contractor's informati)n only. GENERAL NOTES: Cross Pipes are designed for a trover:N)Ing CL load of 10,000 pounds at yield as recorrnended by Research Report 280-2F, "Safety Treatmeit of of Roadside Parallel-Droinage Structure3",* Texas Transportation Institute, March 1981. Safety End Treatments shown herein or� intended for use in those installations where ou- of control vehicles ore likely to traverse the opeiings approximately perpendicular to the Cros5 Pipes. Riprop and all necessary inverts shol be Concrete Riprop conformIng to the requi-ements of Item 432, "Riprop". Payment for riprop and toewoll is included in the Price Bid for each Safety End Treal nent. Cross Pipes shall conform to the requ rements of ASTM A53 (Type E or S, Grade B), AST IA500 (Grade B), or API 5LX52. Bolts and nuts shall conform to ASTM 1,307. All steel components, except concrete reinforcing, shall be galvanized after fabrication. Galvanizing damaged during transport or construction shall be repo red in accordance with the specifications. OF 7�, It LATON ......................... 90298 0,� G/ST 0: The seal aplYearing on this document was authorized by RODNEY LEE SLATON P.E. 90298, on I - 14 - 11 DIN: CITY OF LA :)ORTE RLS CK'D: PLANNING DEPT.ENGII EERING DIV. RLS — 604 W. FAIRMONT ARKWAY APVD: RLS LAPORTE, TEXA ;, 77571 Scale: ENGINEER: RODNEY L SLATON, P.E. OFFICE: 281-47 1-5060 N.T.S. E-MAIL: slatonr@lal Drtetx.gov Date: SITE PLAN NOV., 2011 Project No.: NONE 607 N. HIGHWAY 146 TXDOT DETAU'l- V 2 OF