Loading...
HomeMy WebLinkAbout87-5002 CONSTRUCTION PLANS FOR TREATED EFFLUENT IRRIGATION SUPPLY SYSIM w M z 34: cc 0 M 0 0 0 E2 < cQ 0 LL ug 19 2 .j a- 00,(LIL)i LL z �E , z 0 IOU LL � � , q 0 E 0 rx (D 0 M 'u0L cm ju LOL Ln z LL I-L 0 LLE � 0 co 0 W, M, 0 4. fE LA PORTE P" oc CITY OR LA WASTEIVATE TREATNIEW PLANT 1 I WIINMIM� WME E I 9 ST ry PROJECT LOCATION N.T.S. CONSTRUCTION PLANS FOR TREATED EFFLUENT IRRIGATION SUPPLA SYSTEM PREPARED FOR THE CITY OF LAPORTE —!1 1111 ILKA 1� CLP PROJECT NO.: 87-5002 MORGANS POINT P-0 4a PROPOSED 8"FORCE MAIN FOR TREATED EFFLUENT IRRIGATION SUPPLY CITY OF LA PORTE MUNICIPAL GOLF COURSE z 0 (n F& M0 '96 AMIN mr Up IME C IN. 10 FM IM "r. "rm 610 LA P RTE rN VICINITY MAP ILT.S. If COUNCIL MEMBERS Mayor: Norman Malone Betty Waters B. Don Skelton John Lloyd Jerry Clarke Ed Matuszak Alton Porter DeotTs Gay Mike Shipp City Manager: Robert T Herrera ................ &IL -A.M. 8- ... ...... ESPEY, HUSTON & ASSOCIATES, INC.�-- ENGINEERING & ENVIRONMEN'77AL CONSULTANTS HOUSTON.TEXAS SHEET NO. 1 2 4 5 I INDEX TO DRAWINGS DESCRIPTION COVERSHEET SANITARY EFFLUENT FORCE MAIN PLAN AND PROFILE MECHANICAL Ek STRUCTURAL PLAN,SECTIONS a DETAILS ELECTRICAL PLAN a DETAILS MISCELLANEOUS DETAILS Approved for the City of La Porte-* Robert T Herrera, City Manager MAY 1987 Sheet I of 5 87 50OZ 97-174 I z 0 z 03 0 0 LL. UJI W z >* ;j CL Lu Ld 0 LL in U) z z 0 0 L) U. a. M U Imp 0 rz 0M 0 P MM U) W 10 E Z 0: < 1 W 0 U) U)-::)--LL in 3 LL 1.0 Z W � P� 0 LL 0 00 U W In 4N 8% 221/20 BEND PROP FILL TO COVER PIPE STA. 7+70, 30. U LT 1.5'ABOVE NATURAL GROUND- :9 a. W 8 It x 45* BEN a" a. 2 - &'x 900 BENDS 0- D a: a. 546 STA. 1+75,30.0'LT. ir I R n: POND 3O.Di STA, z z 8 zr < LT. PROP AIR RELEASE It 50' 0 "-VALVE W/BASIN id � � cwr`% 25'R / STA. i r 90, 3O.0 I.T. BREAK/FILL ELEV. EQUAL NAT GND. 17__� ­PR.1 I �F SLOPE TO NAT GND. �10 RCE TMAIN� Ml? ALL AROUND) 3 3rd STREET 4 TB.M. OKO- BASELINE 8 (8d ROW) 2- SN 900 BENDP 35' '0 _S!TLA. �1+75,6�0.0� GRADE TO DRAIN--N ,,A_FND, LP EXIST. 6'CHAIN-LINK FENCE ?5'R-- T-94eAEI�E B"k 450 BEND EXIST 6" RETURN I §� a. I SLUDGE LINE UUNIHOL PANEL STA.5+910,5.d�� S1 F_ tj T 7 X2�� \ # I #I I I It r LA PORTE WASTEWATER TREATMENT PLANT SITE STA. 6155, 5.e' DELETED 8") 6' L 6' 0 CL2 CONTACT BASIN D E E TV 10 BEND BEND PROP FILL:. r t OF RIGHT OF,* WAY WEST PROPERTY LINE -4- EAST PROPERTY LINE 37MI�L — CL R CLR. 10 Cr > 6" RETURN SLUDGE PROP 8" PVC.- SDR 26, CLA 5 8 4' R.Clp I CAST IRON O.D. (C.I.O.D: 5 PIPE BEDDING, SHT. CONTR NO'BEN 0 Ad -5 + 13 W 11 1 LL4 + 4 AD _10 4 z -10 t 11) 0+00 1 2 3 4 5+00 6 7 Z 4CONTRACTOR IS RESPONSIBLE FOR PROPERTY LINE (13 X X !4 VERIFING a LOCATING ALL PIPELINE W 0 g W< CROSSINGS PRIOR TO ANY EXCAVATION. IF- W -P = le = �c 0 W 4 - 0�0 C, 0 0 0 0 -OD W SIR 0 N LO to to =10 =M ro LA POT?7--F- ji L 0 1 - 61 0 Llrr _0 17 15+0P -,-BAS 18 20+00 BASELINE W 4- TO CONTROL REMOTE PANEL ___ / _j Cn �C KAAI Kr PANEL CONTRACTOR 13 TO COORDINATE, K 22h_0 BEND A 7+ 5,5.0'LT 8 !'x 22 1/20 BENDLT STA. 11+7 5.0' 8 nx �2 8!'x 221/20 BEND -I- STA 12+15,15.d RT EAST PROPERTY LINE 8 11 h 22!120 BEND STA. I I+ H. 70, 30.0'LT. LITTLE CEDAR BAYOU 10' (n 8 0 - X 0 �Clj -0 Y <% C? 00 C-0 <0 0 0 Q o U) z _j �r_.F ftpf� 8" BALL a PROR Al 'KET/d VALVE W/ BASIN OINT D, 1, PI IE/j 01 AIN �6 STA 13i-05,30.d RT 00 �20 BEND N, =(D STA.12+60, 3O.d RT. WEST'PROPERTY LINE: OF RIGHT 6F WAY PROP 8" PVC. - SDR 26, FLANGE'w M'*/ -CLASS 16O.C.I.O.D. PIPE BEDDING, SHT 5 OL CABLE )s EST DITCH .160'LF PROP 8 8 9 WE�69§9 S�EEL PIPE I I WELDED STEEL NOTE: FOR FULL LENGTH OF BAbt - SOCKE. _... PIPE ELECTRICAL C�,BLE SHALL BE ENCLOSED IN, A.BS. TUBING (MIN. 1 0) STRAPPED TO SIDE OF 8' FORCE MAIN IN A MANNER ACCEPTABLE TO THE ENGINEER. I 9115A, W8LDE6 STEEL P�� w/ FLANGE TO Md 13 SCALE I"= 5d HORIZ. I"= 5� VERT. 0 .5 14 TEMPORARY BENCHMARK; X" CUT IN THE SOUTH END OF AN 84" RCP LOCATED ALONG THE CENTERLINE OF 3rd STREET, SOUTH OF W STREET. 1978 N.G.S. ADJUSTMENT. ELEV.: 9.64 PROFILE LEGEND: r-rxur-. 0 171 [N::� 11 8 11 X2?-v INSTALLATION OF DISCHARGE STA. 17+90, IN POND "D". 8"PVC PI E NORTH OR EAST PROPERTY LINE SOUTH OR WEST PROPERTY LINE t@! 20, PROP STILLING WELL 01 NORTH OR EAST DITCH OR CURB STA. 17+35, 38.O'RT SOUTH OR WEST DITCH OR CURB PROP 4!X4' CONC. PAD S RISER CENTERLINE OF RIGHT-OF-WAY WATER SURFACE ELEVATION ex 450 BEND STA.18+35.0,100'RT STA. 17+ 70, 30. 0 RT SCALE -PIPE a ELECT. CABLE INSTALLATION /BrX90, BEND SECTION I"= 50' HORIZ. STA. 18+35, IOU RT I"= 5! VERT. N. T. S. WESTPROPE PkOP STILLI�G WELL RTY LINE� HCFCD NOTES i I E DE ',T- OF RIGHT OF.WAY TAIL $HT 5� 10 0 —10 + t 1. Harris CountyFlood Control District,:Inspectim Division, shall be notified at least 48 hours prior to construction (713-684-4040). EA�T PROPItRTY Lit E i L.10.0 - ------ ---- -- --2,-- Engineer sholi- submit letter to Harris County Flood Control District, requesting inspection and occdptance of items constructed in Harris:County, 2 -POND' Flood Control; District Right -of -Way. Prior to requesting inspection, the drainage right�of-way and/or easements shall be staked:and flagged. 3. Contractor shall be responsible for protecting, maintaining and restoring PROP 8"�PVC. SDR'26, dLASS'160 PIPE BEDDING, SIT 5 BOTTOM/PONd EL. 5' backsl6pe droi6age systems. 4-- I i - e; -4— - .0 TV01 � _t_ - -4- + I - 4. All disturbed drabs within the Harris County Flood Control District rfght-of-� CA13LE wo excent t1I channel bottom sholl be hydro -mulch seeded (31 per Harris T t f County Flood, Control specification entitled "Hydro -Mulch Seeding" or� + 4'x4' CONC. + PRCIP 8" RV.C.- ETPR 26 + PF PAD approved equaL CAST IN PLACE, PRIYATE QTfLITY LINFS SHOWN )I (�Xft_ Houston Lighting Power -Co. Date:,4-- 1�2 Entex, Inc Date: Southwestern Bell Telephone Inc. , A0proval only valid for crossing ductlines unless otherwise noted. VALID FOR (1) ONE YEAR ONLY T + 4 SEE� DETAIL SKT. 5 5. Backfill to be ;,compacted in no greater than I foot lifts to the density'of the: 0 t 4 4 1 CONTRACTOR SHALL CALL 223�4567 undistkirbed acljacent soil. NOTE: 48 HOUR'S PRIOR TO CONSTRUCTION + 6. Contractor shall be :responsible for',- maintiining flow in channel, during' FOR CONFIRMATION. OF UTILITIES. t construction and restoring channel to original cpnditiorr. t + 7. All excavated, material is to be removed from the HC17CD right-of-way. No, t fill is to be placed within a designated flood plain aI without first obtaining' -5 + a fill permit. t + 8. Engineer shall �be responsible tor obtaining oll:applicable City; Count�., State,, and + T_ 4- Federal permits. RECORD 'DRAWING T t t JANUARY 29,1:988 -10 k _A 15+00 16 17 18 19 20+00 DEMNED BY: NED IL a ClrY OF LAPORTE SHEET NO. ESPEY HUSTON & ASSOCI Alp"'ES INC, MUNICIPAL GOLF COURSE DRAWN BY: NED Y CHECKED BY' D. D. C. 0 .............. 67gh70ffh?g a ElWirOlMeRfOl CaUldfaVS ED BY WB. U. , Cl * S 928 SANITARY EFFLUENT FORCE MAIN OF 5 SHEETS HOUSTON TEXAS PLAN AND PROFILE DATE AMY, 1987 FLE NO. 10078 NO. REVISION By DATE 6-v-g,7 STA. 0+00 TO STA. 20+00 r% --� � � 37- E Iz 0 0 0 >j w IL LLI 0 IL U) 0 m LL 0 :) ch z 0 z L-Li 9 E ZOO 0 0 rz a 0 CC 8 Uj wzw C.4 LU 0 D Z _j ILL LL 5 0 LL co 0 w ce) A CL2 CONTACT'BASIN 12 NO. 3 �_ 4" DISCHARGE PREFABRICATED PUMP RACK 3/4"GALV. BOLTS FOR DISCHARGE AND BASE PLATE CONNECTION BOLT PATTERN PRECUT PER PUMP MANUFACTURER SPECS. 25� 0" CHLORINE CONTACT BASIN NO. 2 ZPVC. CONDUIT FOR PUMP B FLOAT CABLES OVER WALL =C FLOAT SWITCH _�C�J HANGER I PROVIDE SUPPORT -01 ON WALL PUMP CABLES SECTION A -A SCALE: 3/8 1 = 1, d, 1 1. 2�0" 3 - 6 mm 12'- 6 11 2 0 1 4' 12" 1 ORIGINAL CHLORINE CONTACT BASIN Uj ocr NO. I a \ I >0 ji@,\ a N,,,.11ELDED STL. BRACKET ANCHOR TO EXIST WALL (TYR) 011 _(!) RKPREFABRICATED PUMP RACK PUMP LAYOUT PLAN 11 SCALE: 3/8 = 1'.6, z < DESIGNED BY' NED of I DRAYM BY NED, R.V CHECKED BY: D. D. C. APPROVED BY: WB. M. cis E I DATE MA Y, 1987 NO.1 REVISION BY qDATE v- _e7 5/8" NEOP (SEE DETA 2 c /T*1%, �, _�i RENE PAD IL ABOVE) L3"x 3�'x 1/4"GUIDE SUPPORT x 2%1/4" BRACES 1/4" TYP C6 x 8.2 FRAME I 1_2% 2"x3/8"BRAC 2'x 4'x 3/4" FP_ TO BASE IL BASE PLATE�� 3" (PUMR RACK SECTION) .SECTION B-B SCALE: 3/8�'= I'- d' j PRCPOSED PIPE VALVE & FrrT11NG SCHEDULE I 4"FE/FE DUCTILE IRON IPPE. 2. 4"x 900 FE/FE DUCTILE IRON PPE. 3. 4" FE/FE- DUCTILE IRON P PE. 4. 4n FE/FE WE IGHTED CHEECK VALVE. 5. 4" FE/FE DUCTILE IRON P PE. - ------- ------------ - 6. 411 x 900 FE/FE DUCTILE IRON PPE. 7. 411 x 6"x 900 FE/FE DUCTILE IRON REDUCING PEND. B. 61' FE/FIE DUCTILE IRON P PE. 9. 4" FE/FE DUCTILE IRON P PE. 10. 411 x 6" FE/FE DUCTILE IRON TEE. [1. 6" FE/FE DUCTILE IRON PIPE. 12. 611 FE/FEPUCTILE IRON PPE (FOR METER INSTALLATIO". 13. 6" FE/FE DUCT ILE IRON P PE. 14. 6" x 90* FE/FE DUCTILE IRON BEND. 15. 6" IFERE DUCTILE RON PIPE. 16. 6" x B" x 900 MLI/M.11 DUCTILE IRON REDUCING BEND. FIE - FLANGED END, PE - PLAIN END, MJ - MECHANI CAL JOINT END. I' O"o ---jj�N_V2 (TYP) 1/4" 1/4" R_ 3/8 NEOPRENE PAD RAIL m C:6x8.2 FRAME rwyll 7mm ON 1*141 � : 4 ki I m * TYF 3/4"DIA.xll" THREADED ROD, 5" PROJECTION , SET IN EPDXY (TYP. EA. EBEAM (cb TOP/WALL) !_:�'x3"x 1/4"GUIDE RAIL SUPPORT x GUIDE RAIL BRACKET ___7 dl i�,P,Wv GALV. PIPE STRAPS (5'C-C) I BOLT TO EBEAMS 4 (PRECUT BOLT PATTERNS) i sk, - kL4E TYP (PUMP RACK DETAIL) SECTION D-D SCALE: 3/4"= 1'-0" E61x'Z7���. //r-L:1'x3"x 1/4�'BRACES (PUMP RACK -FRONT) SECTION C -C SCALE: 5/4!'= 1�0" ESPEY HUSTON ASSOCIATES . INC* Engineerlhg a Dwirawental consultants HOUSTON, TEXAS 7Z . I 1. ALL FABRICATED STEEL TO BE HEAVY HOT -DIPPED GALVANIZED. 2. ALL SUBMERGED PIPE (EXCEPT.SLIDE RAILS), STEEL PUMPS9 AND BASES SHALL BE COATED WITH COAL TAR EPDXY (18 MILS). -1 1 1 f-MITAf-T C1 10CAf-9=C Tr% QC C1 I I V Cg=Al UICI Mn UnTW I /On MI I CT WIELDS. 4. ALL STER SHAPES SHALL BE ASTM A36. ALL WELDED SHAPES SHALL COMPLY WrrH AWS STANDARDS. 6" DISCHARGE 1/2% 6" U-BOLT W/ VZ HEX. NUTS kI "-GRINNELL FIG.120 OR EQUAL) �21 WELDED STL. BRACKE (ITT-GRINNELL MEDIL BRACKET NO. 2, FIG. IN 195 OR EQUAL) OP/CONTACT BASIN 3/4!'EXPANSION ANCHOR BOLTS (WELDED STL. BRACKET DETAIL) SECTION E-E SCALE: I " = 1'- 0" NOTE: WELDED STL. BRACKET LOCATED ON PUMP RACK TYPICAL, EXCEPT FOR MOUNTING. MOUNTING IS TO 7 BE 1/4' FILLET WELD ALL AROUND AS SHOWN IN NAT. GRND. SECTION C-C. .DED STL. BRACKET CITY OF LA PORTE MUNICIPAL GOLF COURSE, MECHANICAL a STRUCTURAL PLAN , SECTIONS & DETAILS SHEET NO. OF 5 FLE NO. 10078 3 SHEETS 87-500P 0 z z o 0 LL. 2 1 UJI W �0_1 uj z LLi LLJ M CL 0 ODW U. z U) 0 g 0 0 z (L w 0 E 0 0 a . o 0 0 w om 0-0 b? D W < w U) 0 U. Lo cn _j Z LL U. o u. 0 0 w Im'v NO. REVISION NEW CHART RECORDER 3/4!'C.W/3-#I2THHN, 1-#12 THHN GND DIRECT -BURY CONTROL CABLE NEW FLOW METER TO REMOTEI,PANEL T'a'_AT POND "C NEW CONTROL P 1. L 1L. ANEL Im NEMA 3R ENCLOSURE CHLORINATOR BASINS THICKENER INSTALL 3/4" CONDUIT W/ 3 - # 8 THHN a I - # 10 THHN GROUND w zo 0 _j _j m x PRESSURE 0 IL TANK EX45T,IUMCTION Box USE OXIST. 3/4" CONDUIT a INSTALL 3-#8 THHN a 1-#10 THHN GROUND EP8 #4 HYDROGRITTER EPB#J US� EX I ST. 3 " CONDUIT 8 INSTALL 3 - 8 THHN 1-#IOTHHN GROUND It SLUDGE PUMP, BLOWER Ek SHOP BLDG. DEWATERING BLDG. NOTE: EXIST M.C.C.'B' IS A WESTINGHOUSE 5STAR #HUI-45395-FVC-002 INSTALL 40A/3P E IN EXIST. MCC'B' ( SITE LAYOUT -ELECTRICAL N.TS. T ELEVATION - M.C.C. 1113 11 N.T.S. DESIGNED BY: NED DRAWN BY .* NED , R. V CHECKED By: D_ D. C. APPROVED BY W B. M. DATE : MAY, 1987 v ) . ............. .............. ..... . MAMMA.. STALL 40A/3P 'EAKER 500 VA TRANSFORMER 120/ 240 V PRI. / 24 V S a 1�3P, 40A BREAKER IN Mr,.C. 11 B L 3-1 NOTE: PANEL ENCLOSURE SHALL BE NEMA 3R WITH SUB -PLATE FOR. MOUNTING H-O-AS, RUN LIGHTS ETC. OUTER DOOR SHALL BE EQUIPPED WITH A HANDLE FOR OPENING, CLOSING AND LOCKING. CLIPS ARE NOT ALLOWED. NEMA 3R ENCLOSURE LEGEND CIRCUIT BREAKER MOTOR STARTER FLOAT SWITCH (NORMALLY OPEN CONTACT) FS I CONTROL RELAY CONTACTOR 120V COIL MOTOR STARTER COIL ,R, RUN LIGHT 10% HO 00 HAND, OFF, AUTO SWITCH AO TIME DELAY RELAY ETM 3P,15A 3PI15A 2P, IOA 0 ELAPSED TIME METER 3 - # 8 THHN a I - #10 THHN GROUND IN 3/4%. 3 KVA' CONTACT (NORMALLY OPEN) 480/120-240 CONTACT (NORMALLY CLOSED) TERMINAL BLOCK I OH 15 15 FOR REMOTE PANEL 00 00 —LTC 24 HOUR TIME CLOCK OA OA 7 DIRECT BURY CONTROL CABLE TO CONTROLS (CONDUIT AS SPECIFIED) BY MANUFACTURER SPEC) PUMP CABLE SHALL BE PROPERLY TRANSDUCERS ON PIPE PANEL AT PROTECTED FROM PUMP TO PANEL (LOCATION DETE�MINED POND licil .1 �--Lj L_7EA mEr: WIC. W/3-#8THHN, CHART PUMP #I PUMP 0 2 1 - #12 THHN GND FLOW RECORDER METER ONE LINE DIAGRAM - PUMP CONTROL PANEL H T 120V FROM TRANSFORMER IN PANEL CONTROL DIAGRAM ESPEY HUSTON & ASSOCIATES. INC, Enaineerina a Elwirmmental cmsultants w w HOUSTON, TEXAS NEMA 3R TO PROBES IN REMOTE PANEL PUMP#1 PUMP#2 H NO ------- ):�_ OFF AUTO TO COMMON FOR LIGHTS IN REMOTE PANEL LOCKOUT SWITCH __j 1/2"x 1� COPPER L _ _j PROBEHOLDER GROUND ROD AT STILLING WELL TO PUMP* I LIGHTS _L LL AT STILLWELL IN REMOTE PANEL OFF EL V. ON ELEV. CONTROL DIAGRAM REMOTE PANEL TO PUMP #2 LIGHTS IN REMOTE PANEL NOTES: 1. LLI FOR REMOTE PROBES SHALL BE A C.F. WARRICK #8ZIC0 OR APPROVED EQUAL. 2. WIRE FROM CONTROL PANEL TO REMOTE PANEL AT STILLING WELL SHALL BE AT LEAST 10 PAIRv SHEILDED9 SUITABLE FOR DIRECT BURY, AND INSULATED FOR 135 VDC MINIMUM. WIRING SHALL BE ENCLOSED IN CONDUIT FROM PANELS TO BELOW GRADE. 3. PROBE HOLDER AT STILLING WELL SHALL BE C.F. WARRICK #3E2C. PROBES AT STILLING WELL SHALL BE C.F. WARRICK #3RXC2 OR APPROVED EQUAL. 4. LOCKOUT SWITCH AND PUMP LIGHTS SHALL BE IN A WE4THERTIGHT, LOCKED, DEADFRONT ENCLOSURE AND MOUNTED NEXT TO STILLING WELL. Cl rY OF LA POR rE MUNICIPAL GOLF COURSE ELECTRICAL PLAN AND DETAILS SHEET NO. 4 OF 5 FILE NO. 0078 SHEETS cc Lu ca 0 z m 0 w Ld D 0 0 LL m W w �- uj U) _j 0- ui 2 nn Lj LL 0 5 ao LL W (n zi Zzo LL IL ct j zoo 0 rx 0 0 100 M !,(rL M w lo lu WZW N 0 ll� < 0 L LO L in z _j LL >. LL Irl 0 LL < 0 co 0 ul M in 5LO it MIN. TO CONTROL PANEL I - PRECA I -PRECAST SECTION, �74 R A�CP EU: 4.5 12' "All BANK SAND PLACED BEFORE PIPE IS LAID LOP TO FLOW LINE OF PIPE OR ABOVE MINIMUM DEPTH 511. "B BANK SAND, THOROUGHLY RODDED, PLACED AFTER PIPE IS LAID. ... .. EARTH FILL PLACED TO NATURAL GROUNb. rz 1 r I- 6!' m MIN. 5" -PIPE BEDDING DETAIL NTS -REMOTE PANEL (SEE ELECT SHT. NO. 4) PRESERVATIVE TREATED 0 F ESERV' W 0 ODD POST SET IN CONCRETE Po 3 T FT DEEP LV . I COVER W/ I'x I' GALV. 114 T 'o LHATCH W/ HINGE, HATCH a C LOC LOCK NAT GND. EL.: 12.0 RCP M8" RVC. 8" P`VC' JOINT :2�- 0" �0' MIN. ROUGH CONIC. ALONG LL SLAB AH AR60UND §'x'6','6/6 WWF STILLING WELL DETAIL NTS POND ';9'1. 5 DESIGNED By.- fED OF DRAWN BY (VED CHECKED BY.* D. D. C. .. .. ... APPROVED BY: W B. V. "XISTI NO.1 REVISION By DATE AfAY - 19R7 MAI ;MDATE Wrr" a5'IUw^wq&w_ Fq="CAL m.%'10.4 c_^jtw I%rrcn, 2. CC:P U PlLlegr� F=qw�w 0� I" AFto Ir-Vp�L *40,0 V^,,-vr- <nft <3 TAPPED Tee '�JAAPCO 128SI"JOREQUAL (wrr" V<Sva_&'vr_t_ cmuft"a-1c:t 't�w_ e>F_c> A,.I,,,R RELIEF VALVE BASI POND ,'D" UV 8" PVC. F.M. - INCRETE W. S. E L.; 9.5 6" (Min) �I` /",_--6"x6',6/6WWF ;ONCRETE PAD 3000 psi) a DISCHARGE NTS d In 15- la.cnk b e, ESPEY HUSTON a ASSOCIATES Engineering 8 folmirmmental owsullonts h HOUSTON, TEXAS 9 INC* mug 6 MIN. 15 L8. FELT IFT A DO NOT PERMT MIN, A OR a 6" MIN. CONC. BLOCKING TO BOND TO PIPE OR PLuG FITTING PLAN PLAN PIPE A SIZE TEES a 900 BENDS 450 22 1/20 a I I B 8 It ?1 1 1/4* BENDS a PLUG�. - 1 1.5' 12 3 2' 16 3 21 THRUST BLOCKING, DETAILS- N. T S. 6" DISCHARGE PREFAB. PUMP RACK PUMP RACK 3 - 0 2 go C. FOR CONTROL PUMP CABLES PANEL I 3/4 it C. POWER SUPPLY—, it DIRECT BURY CONTROL CABLE TO REMOTE PANEL 3 it C PRORMETER /-PROP RECORDER 3/4 " C. �'C. FOR FLOAT Cl O� NATURAL GROUND UNISTRUT OR EQUAL I ANCHORED TO EXIST. WALL W/ 1/2" EXPANSION BOLTS (TYP) ELECTRICAL SERVICE CENTER DETAIL SCALE: 1/2"= I�O't ary OF LA PORrE- MUNICIDA IML GOLF COURSE SANITARY EFFLUENT FORCE M41-N MISCELLANEOUS DETAILS SHEET NO. 5 OF 5 HEET S FILE NO. 10078 8 7-50OZ 37- 1745 I I w z z z am 0 cl m o < n 0 W co z M LLJ c) CL U) D LL. 0):D U) z z 0 iz 0 L) -j LL CL -i Z 0 o re CD El I- ui tw) —Z 0 IC) wj) w o U) D LL .19 Z -j >. LL LL 0 LL ict 0 co 0 W M Ln "All - BANK SAND PLACED BEFORE PIPE IS LAID UP TO FLOW LINE OF PIPE OR ABOVE MiNiMUM DEPTH 5i;. "B-1 - BANK SAND, THOROUGHLY RODDED, PLACED AFTER PIPE IS LAID. IICII - EARTH FILL PLACED TO NATURAL GROUND. MIN. 5'1 PIPE BEDDING DETAIL NTS REMOTE PANEL (SEE ELECT S HT. NO. 4) PRESERVATIVE TREATED WOOD POST SET IN CONCRETE 3 FT DEEP GALV 1/4" ?- COVER W/ I'x HATCH W/ H INGE, HATCH Ek 5LO LOCK MIN. NAT GND. EL.: 12.0 TO CONTROL PANEL I - PRECAST SECTION - 24" RCR I - PRECAST SECTION 24" RCP EL: 4.5 121 8" P.vC. RCP JOINT -0 ROUGH CONC. ALO\NG _LM I N." SLAB All AROUND 6'7'6/6 WWF .STILLING WELL DETAIL NTS 3 WZJL#4,�,� Pt-iTiz F-;;pAmvr- * ccyvr-m C�om Apn=mc=kvw irnI mcs�wAI,.,L- wr-rm 2- r-c:puw-vbK- 7 Flo-" od, H=Im V,16,L-vr, TAPPED -ree QA4PCo lZ88MJ6,42 EQUAL- wrrw (SwlA.14r-L- (=muft"m.t=, 'err IlA rc=o 04,111�, I 2. Wrr" W^,L-L- -Q=, IE'>V— W%-r" C-jFk=>cy4mc- "tm-p�L-w-t:0 —TNev-r— It>rrutvmNc=Iulmp OcoN-rsmcam AIR RELIEF VALVE BASIN POND 19 POND I /-� D " 3 8" PVC. F.M. CONCRETE PA me WS. EL.:9.5 6" (MIN.) dlx6': 6/66 WWF 1211 ,CONCRETE PAD (3000 psi) a DISCHARGE POINT NTS Z)- %.0 b PLUS - 11 — .... - .,. L'� �- 4.. '77 15 LB. FELT �l _FT A DO NOT PERWT m1k CONC� BLOCKING TO BOND TO PIPE OR PLUS FITTNG PLAN 6 1 DISCHARGE—) PREFAB. PUMP RACK 6" MIN. A OR 8 PIPE SIZE A TEES B 900 BENDS I B 450* 22 1/2* a 11 1/40 BENDS a PLUGS' 8 It 21 1.5' 3 3 PUMP RACK THRUST BLOCKING, DETAILS N�T S. 0 PROR METER �PROP RECORDER 2%. FOR � � CONTROL L- I I I 1 1 6�-O" PUMP CABLES `\ PANEL -TrF"n F- 3/4" C. POWER SUPPLY---� DIRECT BURY CONTROL CABLE TO REMOTE PANEL FLOAT CABLE HANGEF 6" MIN. - 3/4" C. �'C. FOR FLOAT C4 BASIN t NATURAL GROUND UNISTRUT OR EQUAL I ANCHORED TO EXIST. WALL W/ /?"EXPANSION BOLTS (TYR) ELECTRICAL SERVICE CENTER DETAIL SCALE: 1/2"=1W —D DESIGNED BY NED C17-Y OF LA PORrE SHEET NO. ESPEY HUSTON ASSOCIATES. INC, 5 DRAWN BY NED MLINICIPIANL GOLF COURSE CHECKED BY D.D. C. .. I. ..... C. Engineering 49 &WiraWentl7l 0=111AWS . ................ SANITARY EFFLUENT FORCE MAI-N By W& M. 28 OF 5 SHEETS HOUSTON, TEXAS NO. REVISION By DATE DATE MAY, 1987 MISCELLANEOUS DETAIL S FILE NO. 10078 67-