HomeMy WebLinkAboutBATTLEGROUND INDUSTRIAL PARK, BLDG B-2 SITE PLAN2 a PROPOSED CONSTRUCTION IS LIMITED TO 1,681 SQ.FT. BUILDING EXPANSION AND 739 SQ.FT. OF CONCRETE PAVEMENT. ALL OTHER IMPROVEMENTS ARE EXISTING. CI I ( EXISTING SHRUBS ES AND TREES BI ~`NHL&P FEE STRIP I EXISTING BURMUDA - GRASS PF EXIST 2" WATER LINE EXISTING SHRUBS -< AND TREES Al TO OLD UNDERWOOD ROAD SITE PLAN 1" = 4V T VICINITY MAP N KEY MAP 539 J srq TF y/Gyp q y22S �3�0"R. O �) FLOOD STATEMENT THIS TRACT IS IN ZONE "X" AND NOT WITHIN THE 100 YEAR FLOOD PLAIN ACCORDING TO FEMA MAP #48201C0930L, REVISED JUNE 18, 2007. SITE PLAN ACCURACY CERTIFICATE 1, THOMAS J. MAZINGO, PE, AM REGISTERED UNDER THE LAWS OF THE STATE OF TEXAS TO PRACTICE THE PROFESSION OF ENGINEERING AND HEREBY CERTIFY THAT THE ABOVE SITE PLAN IS TRUE AND CORRECT; AND THAT ALL BEARINGS, DISTANCES, ANGLES, CURVE RADIUSES, AND CENTRAL ANGLES ARE ACCURATELY SHOWN ON THE SITE PLAN. e P� .ey0p .. *o �...........................o �am 5/Z_3�2o13 OC(V ooNA93607 ZIN �oJ MAZ NGO ENG NE INGENC. TBPE FIRM F-13108 C�`��OC4CCcoo��oo TEXAS REGISTRATION NO. 93607 CITY APPROVING AUTHORITY CERTIFICATE THIS IS TO CERTIFY THAT THE CITY OF LAPORTE, TEXAS HAS APPROVED THIS SITE PLAN AND DEVELOPMENT OF WASH BAY TO BUILDING B-2 AT 101 OLD UNDERWOOD ROAD, IN CONFORMANCE WITH THE ORDINANCES OF THE CITY OF LAPORTE. FOR PROPOSED WASH BAY ADDITION BY: �► DIRECTOR, PLANNING ffiPARTMENT EXISTING DETENTION POND r,.:, r::. r,. r. :ter •.: 0 cszda Zm nqW w iil ) Fba y Or coo: a. 0 z D 2 0 WO Ow E �Li 0W _ H/C WELL EXISTING DUMPSTER PAD IST. 4"SAN. SWR, EXISTING BUILDING 15,933 SQ.FT. FIN. FLR. ELV. = 30.10 EXIST. OIL SEPARATOR EXIST. SAMPLE WELL— W .y SHRUBS LISTING CONCRETE PAVING - BERMUDA GRASS.. 10" 10" 6" ALL UNDERGROUND I W DRAINAGE IS EXISTING I 2 I I I CDs EXISTING STABILIZED STARRAA I i STABILIZED LIMESTONE BASE WITH OIL EMULSION FOR DUST CONTROL i I I' T.B.M� EXIST EXIST 8' EXIST 30' WIDE CO CRETE DRIVEWAY I FIRE WATER LINE 10' WATER LINE ESMT EXIST4" HYDRANT N (PR ATE) SAN. SWR. ----- T — — — — — T— — — — — — — T — — — — — — — T---------1----- --- T ------ T — G E G E G G E G E G E G G E Cr — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — 'SAN. — — — — — — — — — — — — — — — — — — �EXIST 8 SAN. SWR. 10' UTILITY ESMT SAN, SWR. PUMP STA. - PRIVATE SAN. SWR. LINE CONNECTS TO CITY OF LA PORTE SAN. SWR. MANHOLE AT 1241 UNDERWOOD ROAD. #4 BARS @ 16" O.C.E.W. _ — 6' SUBGRADE COMPACTED TO 95% STANDARD PROCTOR CONCRETE PAVING N 0 20' 40' 80, EXISTING BAKER BUILDING H STORAGE YARD PLANNING AND ENGINEERING NOTES LANDSCAPING REQUIREMENTS DEVELOPED AREA 139,650 SQ. FT. DEDUCT BUILDING AREA -15,933 SQ. FT. NET AREA 123,717 SQ. FT. LANDSCAPED AREA REQUIRED = 6% OF NET AREA = 7,423 SQ. FT. EXISTING LANDSCAPE AREA SHRUBS & TREES GROUND COVER TO BE BERMUDA GRASS 9,334 SQ.FT. PROPOSED LANDSCAPE AREA SHRUBS & TREES GROUND COVER TO BE BERMUDA GRASS 9,846 SQ.FT. TOTAL LANDSCAPED AREA FURNISHED: 19,180 SQ.FT. = 15% OF NET AREA PARKING REQUIREMENTS 2700 SQ.FT. OF OFFICE SPACE (1 PER 300 SQ.FT.) 9 NON -OFFICE EMPLOYEES (1 PER 1.5 NON-OFC EMPLOYEES) 7 VEHICLES STORED ON SITE: 0 TOTAL REQUIRED 16 PARKING SPACES FURNISHED: (EXISTING) TOTAL REGULAR PARKING SPACES FURNISHED 17 TOTAL HANDICAPPED PARKING SPACES REQUIRED 1 TOTAL HANDICAPPED PARKING SPACES FURNISHED 1 REGULAR PARKING SPACES ARE 9' X 18' HANDICAPPED PARKING SPACES ARE DESIGNED IN ACCORDANCE WITH TAS 4.6.3 AND TAS 4.1.2 - TABLE 2 CITY OF LAPORTE NOTES DEVELOPMENT NAME: BATTLEGROUND INDUSTRIAL PARK, BUILDING B-2 TYPE OF DEVELOPMENT: -PROPOSED 1,681 SQ.FT. WASH BAY ADDITION -PROPOSED 739 SQ.FT. CONCRETE PAVING NAME OF BUSINESS: BAKER CORP. NAME OF OWNER - HOUSTON ASSOCIATES - CALIFORNIA GENERAL PARTNERSHIP. OWNERS ADDRESS - 2780 SKYPARK DRIVE, SUITE 460, TORRANCE, CA. 90505 NAME OF DEVELOPER - HOUSTON ASSOCIATES - CALIFORNIA GENERAL PARTNERSHIP. LEGAL DESCRIPTION OF PROPERTY: 28.2125 ACRES BEING TRACTS 25A, 26A, 27A, 28 & 29 OF STRANG SUBDIVISION JOB ADDRESS: 101 OLD UNDERWOOD ROAD, BUILDING B. BOUNDARIES OF PROPOSED CONSTRUCTION APPX 3.21 ACRE SITE AREA, PER SITE PLAN ON DRAWING S1.1. KEY MAP LOCATION: 539 J FLOOD ZONE: ZONE X, FIRM PANEL 48201C0930L, REVISED 6-18-07 DETENTION: SERVED BY EXISTING ON SITE DETENTION POND. ZONING: LIGHT INDUSTRIAL SITE USE: OFFICE AND WAREHOUSE FIRE MARSHALL NOTE FIRE HYDRANT LOCATION - EXISTING FIRE HYDRANTS LOCATION WITHIN 300' OF BUILDING LEGEND WATER LINE - EXIST - SAN. SWR. LINE -- EXIST — — ■� STORM SEWER - EXIST TELEPHONE CABLE -- EXIST T G GAS LINE - EXIST OVERHEAD ELECTRIC - EXIST E U UNDERGROUND ELECTRIC - EXIST TEMPORARY BENCH MARK NORTH BOLT ON TOP OF FIRE HYDRANT - ELV. = 30.28 - SEE PLAN VIEW FOR LOCATION PLAN NOTES AND LANDSCAPING NOTES O PROVIDE AND INSTALL 85 OLEANDERS IN 5 GAL. CONTAINERS AT 5'-0" O.C. WITH MULTI -ZONE DRIP IRRIGATION SYSTEM. O2 PROVIDE AND INSTALL 2" SCH. 40 PVC IRRIGATION LINE TO NEW LANDSCAPING. 3O PROVIDE AND INSTALL IRRIGATION PVB. O PROPOSED WASH BAY TO SLOPE TO TRENCH DRAIN - CURBS TO BE PROVIDED ON 3 SIDES AND TO BE COVERED TO PREVENT RAIN WATER INFILTRATION. O5 WASH BAY DRAINS THROUGH OIL SEPARATOR AND SAMPLE WELL, THEN CONNECTS TO EXISTING SEWER. Ic Carte r Architects 21175 State Highway 249, Suite 289, Houston, Texas 77070 281 955 0800 fax 281 955 9333 www.CarterArchitects.co 5.23-13 PROJECT Baker Corp PROJECT ADDRESS 101 Old Underwood Road - Bldg B-2 La Porte, TX 77571 PROJECT NUMBER 13012 IB ISSUE DATE May 23, 2013 ISSUE FOR Permit REVISIONS IA SHEET TITLE Site Plan SHEET NUMBER A0.3 3