HomeMy WebLinkAboutBOB JACKSON PROJECT REVISED SITE PLANF-
z
Z_ W
Ul
M
a
X m
2_ �
z
o
fu
z¢
• a
w
r
Ij o
E
d ¢
E
2�
0.
.I
' I HCAD #0240800890001;
� I I I I
' LOUGHRIDGE
LOTS 1-7
I
---J' LOT 5 I LOT 4 l01 3 I LOT 2 ' Lori
-------------1-------------I------------J-------------I-------------�
W ALLEY
y y y
I 10' BLDG. SET BACK i I o 1 I DO y y y y y 4
I I i •� -�.. � 1 I y y y w
i \ CBI ,— 1 I yyyyyyr)
TOCB=20.00 I I y y y l
y y
I DTI) 16" CONCRETE DRIVE
\WITH #41 REBAR @ y y y
I II 12 O.C. I yyyyyy
I III \ I y y y
2 i \ PROPOSED!yl
y y y
METAL I yyyyyyi
I 1
BUILDING I yyyyyy'
I ; �
I ( 3 / I \ 40' X 80'
\ (3,200 SQ FT) y y t
y y y
I / y y y
I I I \ ( y y y
I
1 20'-0. ( 301-0' 40'-0' I y 0'-4' y y y
4 y y y
III \ I y y y y y y
y y y
HCAD #0240800890027; I C \ y y y
ROBERTS
LOTS 27,28
20' BLDG. SET BACK
I
I
i
i
--�----- LOT 28----
I \
�6
\
\
\
7
\
i
\
I
\
18
\
/
/
/
/
/
II
y y y
i yyy yy I
iy y y
Iy y y (
y y y
1 y y y
y y
I y y
Iy y y
( y Y y
y W y
I y y R
1 y W y
MIN❑R DEVELOPMENT SITE PLAN
SURVEY OF LOTS 29-32, BLOCK 689,
TOWN OF LA PORTE, HARRIS COUNTY, TEXAS,
DEED REFERENCE
MAP OR PLAT RECORDED IN
VOL, 58, PAGE 462 H,C,D,R,
TYPE OF DEVELOPMENTi
OFFICE/WAREHOUSE
ZONED,
LIGHT INDUSTRIAL (LI)
OWNER
ROBERT AND JANIE JACKSON
2102 ROCKY CREEK
PEARLAND, TEXAS 77581
DEVELOPERS
ROBERT AND JANIE JACKSON
2102 ROCKY CREEK
PEARLAND, TEXAS 77581
G
N W
Lu
PARKING CALCULATIONSi
LJJ
O
Q
p-
4 (MIN) PLUS
3 PER 1,Q FT.OEFEMPLOYEES
ONON-OF
OFFICE 3
0
=
1 PER 15 ICSQ.
3
a
TOTAL OF 10 PARKING
SPACES- 1 HC ACCESSIBLE
OVERHEAD 200A
SERVICE ENTRANCE
240/120V td 4W
NOTE TO THE OWNER:
PRIOR TO
CHANGE OF OCCUPANCY,
OWNER MUST
COORDINATE WITH CITY
OF LA PORTE
REGARDING PARKING DEVELOPMENT.
y y POWER
FF=21.00 i y y y POLE
Iy y
Iy y
y y y y S j
I yyyyr
y yyyy4 Jib
Y y y e4 �!
y y y
B I TO
CB
M
s
I I ---r--
WI I I \ \ I
a1111 \ I
NIII I O \
0I
�116" CONCRETE DRIVE
I \
` i WITH #4 REBAR @ I of
12 O.C. I
_ .iV7 — - — — - — LOT 30 --- --
OPEN DITCH SYSTEM _ _ — _ _24• RCP Cw vERr _'_J _ - — - -
pI PROPOSED CONC. DRIVEWAY
�' MEET EXISTING PAVEMENT.
10" SANITARY SEWER MAI
S S S S
NORTH 16TH STREET
(60' R.O.W.)
SITE AND DRAINAGE PLAN
ti
CURB
DETAIL 2 SIDEWALK
DETAILS
•ILI�ij y
y
y
Y
�
.tQ
yN
Ji
(y
j
A?O
------ — 0'--- --- --- -- t
£
3/4' WATER
METER AND TAP
OPEN DITCH SYSTEM BY CITY
�O
'•cS S S S
THIN WALL KNOCK
OUTS, TYPICAL ALL u
2'-0' er Ln"so°cwa
1 ALL CATCH BASINS 2024 00
4500 PSI CONCRETE
H-20 LOADING oo N
00
PLAN
ELEVATION 18'X18'X30' CATCH BASIN
—
>
DRAINAGE PIPE DETAIL
u+or UK" CONCRETO
4' SANITARY SEWER
TAP BY CITY
POWER POLE
GENERAL NOTES
1. THIS SITE PLAN IS NOT A SURVEY, BUT RATHER A SURVEY
PREPARED FROM A SURVEY DONE BY C, A. MCKINLEY DATED ON
5/16/04.
2. THIS TRACT DOES NOT LIE WITHIN THE 100
YEAR FLOOD PLAIN ACCORDING TO THE FEMA MAP PANEL NO,
48201CO945J, REVISED N❑VEMBER 6, 1996 (ZONE 'X'),
3. LAND TO BE DEVELOPED AT THIS TIME CONSISTS OF
LOTS 29-32 OUT OF BLOCK 689, TOWN OF LA PORTE,
4, PROPOSED BUILDING SHALL CONSIST OF 2 USE GROUP SECTIONS;
2,720 SQ, FT. WAREHOUSE AND 480 SQ, FT, ❑FFICE AREAS.
5. UTILITIES AVAILABLITY REQUEST; #UV-04005,
6, LETTER OF INFRASTRUCTURE L❑CATIONS #CDR-04-012,
7, CITY SIC CODE SHALL BE DETERMINED AT THE TIME OF LEASE.
IRE HYDRANT LOCATED AT NE LANDSCAPE CALCULATIONS
CORNER OF N. 16TH STREET
AND W. ADAMS STREET R.O.W., DEVELOPED PORTION OF LAND = 12,500 SQ. FT, (.286 ACRES)
APROX. 85 FEET AWAY DEVELOPED BUILDING = 3,200 SO, FT,
S S 12,500 SQ. FT, - 3,200 SQ. FT, = 9,300 SQ. FT.
REQUIRED LANDSCAPE 6%
9,300 SQ. FT, X 6% = 558 SQ, FT.
SCALE: 1" = 10' I 03
0h9
C WP 1w"
>
p� VARIES
DRAINAGE PIPE DETAIL
(UNDER CC14CRETD
TOTAL LANDSCAPE
REQUIRED LANDSCAPE < PROVIDED LANDSCAPE
558 SF < 1608 SF
SCALE: NONE( 02 I NOTES TO SITE AND DRAINAGE PLAN
DETENTION CALCULATIONS
AREA = 110' X 125' = 12,500 SQ FT, (.286 AC)
Cs = .20 AC -FT/ AC
DETENTION REQUIRED
12,500 SQ FT X .20 AC -FT/ AC = 2500 CU FT
22FACE DETENTION AREAS
'A' 3925 SQ FT X .50' X 2/3 = 1308 CU FT
B' 3603 SQ FT X .50, X 2/3 = 1201 CU FT
TOTAL SURFACE DETENTION = 2509 CU FT
TOP OF CONCRETE = 20.50
WATER LEVEL = 20.17
C.B. DIA L CAP/FT CAP -TOT _
A—B 18' 84,85 FT 13,22 GAL 1121.72 GAL
C—B 18, 21.85 FT 13.22 GAL 288.86 GA
TOTAL 1410.58 GAL/ (7,481 GAL/CU FT) = 188.5 CU FT
TOTAL DETENTION
REQUIRED DETENTION < PROVIDED DETENTION
2500 CF < 2697 CF
PIPE SIZES/LENGTHS
18' PIPE = 106.70 FT
6'PIPE =I2FT
USE OF A 6' FLOW RESTRICTOR
This is to certify that the City of La Porte, Texas has
approved this site plan and development of BOB JA KCnN
In conformance with the laws of the State
of Texas and the ordinances of the C y of La Porte,
B/I - -- - �----
Director, L Porte Planning
Department
Atte ty+-,,gg,��ff��,
ByiJ11,_---•
La Porte City E eer
Ati-------------------
P,O. Box 1115
604 West Fairmont Parkway
La Porte, Texas 77572-1115
I, AM REGISTERED UNDER THE LAWS OF
TEXAS TO PRACTICE THE PROFESSION OF ENGINEERING
AND HEREBY CERTIFY THAT THIS MIN❑R SITE PLAN IS
TRUE AND CORRECT AS TO PROPOSED SITE IMPROVEMENTS,
JIMMIE D, C❑KER, P,E.
TEXAS REGISTRATION NO, 10259
X
1
O
LO
SCALE: NONE
•
- architecture - design -
- construction managem
530 So. Broadvw
La Porte, Texas 7T
Office: 281.787.0552 Fax: (281) 471
www.projectdesignpartners.a
PROJECT NUMBER
PROJECT TITLE
z -LWLI�
U) `�
U
U LU
--� (
^
O=IW-
m 0
On"z°°-
m J
N
N
.�.���.
PAffES51OYAL SEAL
M.41. tit
® °�'•• A.
®�
A
� 0
DRAWINGS ISSUED FOI
OWNER APPROVAL
PROGRESS PRINT
FINAL PRINT
SCOPE OF THE DOCUMEI
THIS DRAWING INDICATES THE GENERAL SCOPE OF
PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT
DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECT
ELEMENTS AND THE TYPE OF STRUCTURAL, MECHAN
ELECTRICAL SYSTEMS. AS SCOPE DOCUMENTS,
DRAWINGS DO NOT NECESSARILY INDICATE OR DESCRIBE
WORK REQUIRED FOR FULL PERFORMANCE AND COMPILE
OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS
THE BASIS OF THE GENERAL SCOPE INDICATEI
DESCRIBED, THE CONTRACTOR SHALL FURNISH ALL 11
REQUIRED FOR THE PROPER EXECUTION AND COMPLETIO
THE WORK. THESE DRAWINGS SHALL NOT BE USED
CONSTRUCTION UNLESS DATED AND NOTED AS ISSUED
CONSTRUCTION WORK. THIS DOCUMENT IB THE PROP
OF Ig-"- rAND IS NOT TO BE USEI
WHOLE OR IN PART, WITHOUT THE WRITTEN AUTHORIZATIC
WAO%k M
IF THIS RAR ODES NOTMEASURE P THEN DRAWING I
NOT TO SGgLE
DRAWN BY:
CHECKED BY:
DATE
DPL
2004/07
SHEET TITLE
SITE &
DRAINAGE
PLAN
DRAWING NUMBER
SHEET NO.
CO2
1.1