HomeMy WebLinkAboutEXXON COMPANY USA SITE PLANE
a
z
is
I
3 z
J
a
w
ox�
z
�
n
Aa
�o
I�
�
a
�
3
ap
0
o
aw
o
U
W
3
a
� C)
00
cl
00
ON
RESET 1' I.R.
FND. 1" I.R.
I
I
'
(FIND. 1" I.R.
N 80'41 31.E _ _
�'--
2
J
1
SAMPLING' W1711.
`I WY 1
it
O
a
ul
O
N04
K W
CONCRf:.?i: Pn'Vt:MF..tiT
�
$ wm
V
8'-6
{' I WATER wi
It I M (Ea
z
Z
...._ .....
.....__.._
I
�
fEXIST.f
T P AR Kw AY
A'R1 `MON 250' ROW
CONCRETE PAVING
NOTE TO CONTRACTOR
L
UTIONH
IFY LOCATION OF UNDERGROUND
KS AND PRODUCT LINES BEFORE
AVATING. USE EXTREME CAUTION.
TRAFFIC SIGNAL.
SITE SPECIFIC DRAWINGS
69403-1
SITE PLAN
69403-2
GRADING PLAN
69403-3
ELECTRICAL PLAN
69403-4
PLAT OF A SURVEY
69403-SG
BUILDING ELEVATIONS
(ILLUMINATED PANELS/SIGNS)
CARWASH
4732A-1
FOUNDATION
4732A-2
FRAMING
4732A-3
FLOOR PLAN
4732A-4
ELECTRICAL/PLUMBING
4732A-5
CAR WASH LAYOUT
4732A-6
SECTIONS
PAVING
8-0025A, 1-4 PAVING DETAILS & SPECS.
DETAILS
1043-1,2
�Po
R
??S
NORTH w
mz PASADENA BLVD.
SPENCER HWY.
FAIRMONT PKWY
SITE
VICINITY MAP
KEY MAP #579-E
NTS
���1:4
0 20 40 60
SCALE 1` 20'
PROJECT DESCRIPTION AND ADDRESS
EXXON CAR WASH ADDITION, 9803 FAIRMONT PARKWAY AT UNDERW00D
OWNER/DEVELOPER
EXXON COMPANY, U.S.A.
A DIVISION OF EXXON CORPORATION
LEGAL DESCRIPTION
0.918 ACRES IN THE WILLIAM H. JONES SURVEY, A-482, CITY OF
LA PORTE AND OUT OF OUTLOT 719 OF THE W. B. LAWRENCE
SUBDIVISION RECORDED UNDER VOL. 83, PG. 344, OF THE DEED
RECORDS OF HARRIS COUNTY, TEXAS. SEE ALSO DEED DATED
JULY 29, 1986 FROM W. H. KEENAN, TRUSTEE, ET. AL. TO EXXON
CORPORATION AS RECORDED IN H.C.C.F. NO. K657705.
PARKING
REGULAR PARKING SPACES 13
HANDICAP PARKING SPACES 1
TOTAL PARKING PROVIDED 14
LANDSCAPING
LANDSCAPING: 24%
LOT COVERAGE: 76%
CITY APPROVING AUTHORITY CERTIFICATE
THIS IS TO CERTIFY THAT THE CITY OF LA PORTE, TEXAS
HAS APPROVED THIS SITE PLAN AND DEVELOPMENT OF
EXXON RAS NO. 6-9403, CAR WASH ADDITION IN
CONFORMANCE WITH THE ORDINANCES OF THE CITY OF
LA PORTE.
BY:
DIRECTOR, LA PORTE COMMUNITY
DEVELOPMENT DEPARTMENT
ATTEST:
BY:
LA PORTE CITY ENGINEER
2
=
mr
w
s
�1
m
$
r
N
=
GENERAL NOTES
G. C. GENERAL CONTRACTOR
E. = EXXON
0. OTHER
m BUILDING ORIENTATION POINT
ETR EXISTING TO REMAIN
MWE G-1 MEET EXISTING GRADE
1. ALL UTILITY CONNECTIONS ARE TO BE AS PER LOCAL CODE BY G. C.
2. G. C. TO PROVIDE CONDUIT &WIRING TO All EXXON
SIGNS & CONDUIT ONLY TO PUBLIC TELEPHONE BOOTH.
3. SITE PLAN SUPERSEDES ALL WORKING DRAWINGS.
14. UNLESS OTHERWISE NOTED, ALL PAINT TO BE FURNISHED BY G. C.
BUILDING
DRAWING NUMBER
1
GC
GC
CAR WASH BUILDING W/O RECLAIM., BUILDING SHALL BE DESIGNED FOR
4732, 1-5
100 MPH WIND SPEED, WITH ROOF OPTION.
0
0
CAR WASH EQUIPMENT 240/120 3-PHASE 4-WIRE
E
GC
2 VACUUM CLEANERS
2
GC
GC
TRASH ENCLOSURE
6-9403, 1043-1.
1043-2
3
E
GC
INSTALL INTERNALLY ILLUMINATED BUILDING PANELS
6-9403, 3
YARO AREA
10
1 E
GC
AIR/WATER
6-9403, 1043-1,
1043-2
11
1 GC
JGCJ
CAR WASH "ENTER" & "EXIT" SIGNS, 1 EACH
4732-5
ELECTRICAL/TELEPHONE
20
GC
PROVIDE NEW SERVICE SWITCH RACK PER NEC AND CITY ELECTRICAL
6-9403, 3
JGC
CODE. COMPLETE WITH CAN & METER, GUTTER, 400 AMP DISCONNECT
(C-STORE SERVICE) & 200 AMP DISCONNECT (CAR WASH SERVICE).
21
GC
GC
EXIST. SERVICE DROP POLE TO REMAIN. PROVIDE NEW SERVICE
6-9403, 3
WEATHERHEADS TO NEW SERVICE RACK. INSTALL NEW CONDUCTORS &
CONDUIT PER ONE UNE DIAGRAM.
22
GC
GC
HL& P TRANSFORMER POLE W/ NEW 240/120V 3-PHASE 4-WIRE
SERVICE DROP BY HL& P.
23
GC
GC
EXISTING 3" U/G CONDUIT (C-STORE SERVICE) TO REMAIN.
24
GC
GC
EXISTING 400 AMP 2P MAIN CIRCUIT BREAKER TO REMAIN.
25
GC
GC
NEW 200 AMP 240/120V. 3-PHASE 4-WIRE CAR WASH SERVICE.
6-9403, 3
26
GC
GC
PROP. 2" U/G CONDUIT FOR NEW CARWASH SERVICE. INSTALL
6-9403, 3
NEW CONDUCTORS PER ONE LINE DIAGRAM.
27
JGC
10C
INSTALL 4 NEW YARD LIGHTS
6-9403, 1043-1
28
1 GC
JGC
RELOCATE 2 EXISTING YARD LIGHTS PER EXXON ENGINEER
6-9403. 1043-1
29
1 GC
JGCJ
RELOCATE PUBUC TELEPHONES AND U/G CONDUIT PER EXXON ENGINEER
PAVING
40
GC
GC
6" CONCRETE W NO. 3 BARS ® 18" OC EACH WAY PREPARE
8-0025A, 1-4
SUBGRADE BY COMPACTING TO AT LEAST 95X OF MAXIMUM. ASTM D698
SAW CUT AT EDGE TOR MAIN. PRESERVE MIN. 12" OF EXISTING
REINFORCEMENTS & TIE TO NEW REINFORCEMENTS WHERE REQUIRED.
41
GC
GC
6" CURB PLACED ON NEW OR EXISTING CONCRETE PAVEMENT
6-9403, 2
42
GC
GC
NOT USED
43
GC
GC
ACCESSIBLE RAMPS TO BUILDING PER CITY CODE & TEXAS
ACCESSIBILITY STANDARDS. EXISTING TO REMAIN
44
GC
GC
ACCESSIBLE ROUTE, MIN X-O" WIDE PER CITY CODE & TEXAS
ACCESSIBILITY STANDARDS
45
GC
GC
4'-0" WIDE CONCRETE SIDEWALK PER CITY SPECIFICATIONS
46
GC
GC
PAINT ALL NEW STRIPES TO DELINEATE PARKING AND ACCESSIBLE
ROUTE
LANDSCAPE
50
1 GC
JGCJ
LANDSCAPING AND IRRIGATION SYSTEM PER EXXON ENGINEER
WATER
60
JGC
JGCI1
1 2" CAR WASH SUPPLY UNE FROM EXISTING BUILDING SUPPLY
UNE PER CITY CODE. WATER LINE SHALL BE PVC PRESSURE PIPE
ASTM D-2241 CLASS 200 (DR21) W/ RUBBER GASKET JOINTS
SANITARY SEWER
70
GC
JGCJ
TIE-IN TO EXISTING SEWERS SHALL BE PVC PIPE MEETING STORM
SEWER SPEC. (SEE NOTE 81)
71
GC
JGCJ
SAMPUNG WELL PER CITY OF LA PORTE STANDARD
6-9403, 2
72
GC
JGCJ
MUD AND GREASE TRAP PER DETAIL
4732-1
STORM SEWER
80
GC
JGCJ
TIE-IN TO EXISTING INLET
81
GC
GC
INLETS, STORM SEWER DRAINS AND DRAINAGE SWALES, STORM SEWER
DRAINS SHALL BE PVC PIPE, ASTM D 3034, W RUBBER GASKET
JOINTS ASTM D 3132 AND F477
82
GC
GC
INSTALL NEW TRENCH DRAIN
6-9403, 2
"FLOOD NOTE"
THIS SITE LIES IN FLOOD ZONE "X" (NOT IN FLOOD PLAIN) PER
PHILLIP HOZA OF THE CITY OF LA PORTE.
SITE PLAN ACCURACY CERTIFICATE
I, DAVID S. BREWER, AM REGISTERED UNDER THE LAWS OF THE
STATE OF TEXAS TO PRACTICE THE PROFESSION OF SURVEYING AND
HEREBY CERTIFY THAT THE ABOVE SITE PLAN IS TRUE AND CORRECT:
AND THAT ALL BEARINGS, DISTANCES, ANGLES, CURVE RADIUSES, AND
CENTRAL ANGLES ARE ACCURATELY SHOWN ON THE PLAT.
OF 1�0
DAVID S. BREWE
TEXAS REGISTRATION NO. 4042
5-5-95