12"
GENERAL NOTES
CON TR CTION, PL N
FOR
,*FA
9XWiiW9.
E ST F I
CITY
l.. Contractor shall verify and flag the location of all underground
utilities and pipelines prior to working in the area.
2. All underground utilities shown are not guaranteed to be complete
or definite but were obtained from the best information available.
3. Contractor shall notify all utility and pipeline companies a
minimum of 48 hours prior to commencing construction. Contractor
shall be responsible for all coordination and staking of existing
utilities with no extra pay.
4. Contractor shall provide satisfactory supports for buried
utilities, pipelines, and other facilities which will be exposed
during construction.
5. Contractor shall establish existing grades and dimensions of roads,
ditches, culverts, driveways, etc. before their removal for use in
their subsequent restoration.
6. owner to obtain all permits required by Harris County, Texas prior
to starting construction of utility and/or culverts within county
road right-of-way.
7. one (11) foot clearance shall be maintained horizontally between
Entex gas lines and proposed sanitary at all times.
8. Contractor is responsible for reconnection and rerouting any
sanitary house connections that are cut by abandoning existing
sanitary lines.
9. Contractor shall be responsible for restoring area used for access
to construction site to its original or better condition, with no
extra pay.
REPLACEMENT
AT 'DEER CREEK
_e ESPEY, HUSTON & ASSOCIATES, INC.
hEngineering & Environmental Consultants
888. West Belt Drive South Suite 200 Houston, Texas 77042 (713) 781-8800
STANDARD H.C.F.C.D. NOTES
1. Harris County Flood Control District, Watershed
Management Department, shall be notified at least
t t t' 713-6
a
SANITARY SEWER SYSTEM CONSTRUCTION NOTES
4s hours prior o, cons ruc on ( s .a -.
7. Whenever +a sanitary sewer line crosses under a water line with
7. All excavating material is to be removed from the
HCFCD Right -Of -Way. No fill is to be placed
greater than two feet, but less than nine feet of vertical
within a designated flood plain area
without first
clearance, the portion of the sanitary sewer within nine feet of
obtaining a fill permit.
the water line shall be backfilled with cement stabilized sand
-(minimum 2 sacks cement per cubic yard of sand) to a depth of one
S. Contractor, with the assistance of the Engineer if
pipe diameter or twelve inches (whichever is greater) above the
sewer line.
necessary, shall be responsible for
obtaining all
applicable City, County, State,
and 'Federal
8. Whenever a sanitary sewer line crosses over a water line with
permits.
greater than six inches,; but less than nine feet of vertical
- - -
AN
clearance, one eighteen foot joint of ductile iron pipe (a.W.W.A.
C151, 150 psi., Thk.C1.50) shall be installed in the sewer line and
centered at the water line crossing.
°
VICINITY MAP K.M.580 C
(SCALE: I"= 2 Mi.)
INDEX OF SHEETS
SHEET NO. DESCRIPTION
I TITLE SHEET, PROJECT
LAYOUT,NOTES
2 PLAN AND PROFILE,
DETAILS
Approved By o d6adSy
City oaf LaPor e, Texas Date
V
• � 0
J
EAST
:' PAPOP. SA Al Ad.H.
F
Q PROP. /Z'( SAK. SWAP.
EXisf /O "9an• �_ "L`X%Sro! 8"gan.
EX sf 8'San. PROP. SA
PROP. A R/A4 CROSS/NG STUf3-OLIT
0
OR��E
PARK
EAST 4F �1
Job No, 12789-01
SHEET NO, I of 2
/lw woo w A,
a
M
0
0
z
z a _
Qo
0
M
Z
z
m
w
0 0
0
0
x
3
a
C7
1
z
�
�
I
U
U
Ld
0
o
ff
0. U
0
w
W
0
W
Q
o
IU
0
¢ =
^`
v
O
x
y
�
a
it
� H
nnna
none
111119
nnn�
L 94
INSTALLATION INSTRUCTIONS
1. Excavate for manhole in normal manner.
2. Make cut -nut, keep as close to size as possible. A saw with carbide grit. carbide tip or masonry blade is
recommended for making cut-out. Make sure cut so as a minimum of 4" of utanhole will embed into concrete base. I" PIPE FA
3. Set depth of manhole so that a minimum of one concrete ring can be installed for adjustment of cover to final grade. ( WELDED)
4. Minimum concrete stab base required. (6'x6 x6' deep) -
5. Recommended handling procedure: Insert a WxWOO" timber into top of manhole with cable attached. Lift as
required.
6. Place manhole in position. The depth of the manhole in the concrete is to be 3" min. and a min. of 2" of concrete
beneath manhole.
7. Level manhole.
8. Seat by working concrete around base and cut-outs.
9. Back fill: Allow base to set and proceed to back fill as soon as possible. Back fill to be added in 12" lifts to avoid
excessive pressures.
T� _
/� 5>:d• 231fz"Fnmc
I -- ocbncre/e QIM14
I
6'
1 %2 3" II/2•
-J�- TO FIT" D. PIPIt EED
PIPE
NI
DRILL 258"0 HOLES EACH END AS SHOWN
2xsx%. t WELDED TO EACH END
PIPE CLAMP DETAIL
Lifting eyes
I �'*...__�J OrequiredPer
#21 /o be lied la NOTE:
J�c/ion/. m2C) .,.
/'/V"V � x1pCA - ' PIPE GUARD TO BE PAINTED IN
TT
Iu�v
L38 93
u
�
� :t
u
It
i
x '
W �
C
F
L
b
L V
4'
�'1c Sfa. 3t24.G6 � �
T EXi s7< 5'ar7. IV Al. No. //54
'e., P' e
I ACCORDANCE WITH CURRENT
SPECIFICATIONS FOR "PAINTING
STEEL CARRIER PIPE'
11/ " F
MITRE WEI
tr?E. FIPE
45" MITRE
�= 4.53 4Ff. Die.
APPROVED: ��'� (To /3E ,PEMoVEo)
OG F1. $gaare
g?a. -u
WARNING Hams county Flood ColiGDi District ��
Overhead lines may exist on the property. We have not 71//1 TD FIBERGLASS MANHOLE
attempted to mark those lines singe they are clearly - ^-7 SEQUENCE OF CONSTRUCTION: N.T.s.
visible, but you should locate them prior to beginning Date
any construction. Texas law, Section 752, Health 6 Safety THE ABW6 SIGNATURE VALID I . CONSTRUCT MANHOLE NOTE
Code, forbids all activities in which persons or things MAY FOR (1) Y�i( QNL.Y 2. SET UP TEMPORARY PUMPING REINFORCING BARS SHALL 8E NEW, DEFORMED
come within six (6) feet of live overhead high voltage lines. It 4-NO. 5 VERT. BARS �� INTERMEDIATE GRADE STEEL WITH NO SPLICES
Contractors and :Owners are legally responsible for safety of 3. PLUG 8 SANITARY UP a DOWN STREAM S NO.3 SPIRAL AT 6" .`
A. S.T. M., A-305, A-15.
construction workers under this law. This law carries both 4. REMOVE CROSSING T.B.M. cTR6. / t CONCRETE SHALL BE CLASS "B"
5. INSTALL PILE AND CASING CHISELED "X" EAST RIM SANITARY �- MIXED AND PLACED PER SPEC.
criminal and civil liability. To arrange for lines to be MANHOLE NO.1154. / 1.
turned off or moved, call HLBP at 228-7400. 6. INSTALL SEWER AND MAKE TIE-INS ELEV.= 13.43 \�1sr/ _ e"R.- ( �2-T/a HOLES
AT EACH 7. TEST 2 FLAT LOOPS OF SPIRAL STRAP 3/8'x z I/2" STEEL
SECTION. ND OF REINS +'-I I �-
...� ,___ _.__ --_ ;. _._ --.- _._. _ ;... �. -.., :. _. • Ott%I� �G�/G: _ -
/ =20
i.. :...- ;.. ,.-....... ,. f. ::. 18"SONOTUSE TOO BEN---_..,
2�
AFTER CONC.
rN n
14 CURES
ED
CONCRETE SURFACE TO BE
I I
a +
t
pit I Fn ANn TROWELED
F DETAIL
'ION
CAP REINFORCING
o
- - _
1 I
T/e EX%Sit "San. Sw� DRILL SHAFT TO FIRM -
TO P/-OP. �'" rJ.M H. CLAY BOTTPM ---� m
22„ I"R. ALL BENDS
\ / to
2 NO 3 BARS REDUIR
7-/;- Prop. /Z"5'an• wr. iq{v { 5'an. Swr *SIMILAR PRECAST PILING
EXl's-f San. M.H.- 3.47 _ - - - •_ --
/f IS ACCEPTABLE
// CONCRETE PILING FOR SUPPORT OF 20" STEEL CASING
,
V r
l
Np -- - - ---- p
�1N!N
Of 00 > Z 3 3 f-5O
DESIGNED BY
PRAWN BY : // i%� % ®,t, •..
°'' - ESPEY, H USTON & ASSOCIATES, I NC@
CHECKED BY : DCONt3E
A ..............
4627Q......:
,STER��.��� Engineering & Environmental Consultants
APPROVED BY: y111 �1`ON ...
DATE : t/u/if 5r /990
N0. REVISION BY DArE 888 West Belt Drive South Suite 200 Houston, Texas 77042 (713) 781-880CI
t
N.T. S.
STEEL CASING TO. EXTEND
10 MIN. INTO BANK (TYP.)
PER EACH
WELDED STEEL PIPE CASING. ---,
1.0. OF CASING PIPE TO BE A
MIN. OF 2" LARGER THAN O. D.
OF BELLS ON.,SAN.SWR
T
CASINO INSULATOR B SKIDS BY MALONEY
(OR EQUAL) AT BELL AND SPIGOT ENDS
OF CARRIER PIPE AND AT MIDSPAN OR
10' O.C. WHICHEVER IS LESS.
I TYPE "Alt CASING
AERIAL CROSSING CASING DETAIL
•-"TABLE OF DIMENSIONS
FOR VARIOUS PIPE SIZES
I6"
20"
24"
30"
36"
A
II /4
2-3.43
2-T
3•I
-7 /
B
W4'
2 /q
3-6
i0
410
C
46 /
4.6
4.6 /4
5 !
4.6 /q
D
-5/
2".
6L 0312
8^x � �I/p'x23/q"MACH, BOLT -.
(SEE DETAIL) (4 REQUIRED)
PIPE GUARD DETAIL
N.T.S.
NATURAL GROUND
COMPACT SELECT
EXCAVATION MAIL.
% /
�SOILSTURBED
TO 85%STD PROCTOR
DEENNSITY(12'ILIFTS
a
COMPACT' TO BS',
% ae
PIPE'ij
i � %
•F- :i
STO. PROCTOR
DENSITY48"LIFT
a
d
MAX.)
N.T. S. eZ-P -` 90 - 71 Off} -
CITY OF La PORTE TEXAS
12 SANITARY SEWER REPLACEMENT
PLAN 81 PROFILE
CRUSHED ROCK,
WASHED SHELL OR
2500 Pal CDNC.
FOUNDATION ONLY
IF REWD. 9APPRCM
9" PIPE 9" BY ENGINEER.
MIN O.D. MIN.
PVC(USUAL)-►6"THROUGH 15"--ASTM
D-3034,SDR 26
,PVC(CLASS 150 AS REO'DJ-�-6"
-THROUGH-15"-AWWA C-900, DR-I8 OR
ASTM D-2241,SDR26,PLP O.D-(15")
TYP. EMBEDMENT DETAIL
( PVC PIPE)
N.T.S.. _....
I TOP of TIMBER
BENT EXPOSED
IN SLOPE
I/2" X 22"-'
GALV. BOLTS
Dio. PILE
��
�a_Ci
o~ N �
0
PILING AND TIMBER.
TO BE PRESSURE
TREATED WITH,AN
APPROVED PRESERVATIVE
TIMBER BENT DETAIL
N.T.S.
SHEET NO. 2
STA.0+00 TO STA) 3+30.78 of 2 SHEETS
MISCELLANEOUS DETAILS FILE NO.12789-01