HomeMy WebLinkAboutMUNICIPAL COURT FACILITYHVAC ABBREVIATIONS ABBREVIAliON DESCRIPTION ABBREVIA liON DESCRIPTION SYMBOL ACU AIR CONDiliONING UNIT HWR HOT WAlER RETURN ~ AF AIRFOIL HWS HOT WAlER SUPPLY ~Ztf'i'1 AFF ABOVE ANISHED FLOOR ID INSIDE DIAMElER AHU AIR HANDUNG UNIT IN INCHES [2] AI ANALOG INPUT IN H.O INCHES OF WA 1ER (PRESSURE) IZI AO ANALOG OUIPUT IN we INCHES WAlER COLUMN (PRESSURE) B BCU BOIUER BLOWER COIL UNIT IN KW WG INCHES KILOWATTS WATER GAUGE (PRESSURE) [~ 2J BACKWARD INCUNED (FANS) OR r<:71 Bl BINARY INPUT (CONlROLS) LAT LEA\1NG AIR TEMPERATURE .. "'" BO BINARY OUIPUT. MAU MAKEUP AIR UNIT 121 BTUH BRITISH THERMAL UNITS PER HOUR MAX MAXMUM lZl MBH THOUSANDS BRiliSH THERMAL c COMMON UNITS PER HOUR r?> <{_j CD CONDENSATE DRAIN MCA MINIMUM CIRCUIT AMPS CFM CUBIC FEET PER MINUlE MECH MECHANICAL {F1 CL CENlER UNE MIN MINIMUM + 10/8 ~ CHWP CHWR CHILLED CHILLED WAlER WATER PUMP RETURN MDCIP PROTECTION MAXIMUM OVER CURRENT + I ~ MZ MULliZONE CHWS CHILLED WAlER SUPPLY I I N/A NOT AIPPUCABLE ...::::::::12'' cu CONDENSING UNIT I ...::::::::15/12- 1 cv NC NORMALLY CLOSED Jb I CONSTANT VOLUME NO NORMALLY OPEN I DB DRY BULB No. NUMBER (QUANTITY) + fS. dB DECIBELS Dl DIGITIAL INPUT NTS NOT TO SCALE I { ~E\1~ElwE OA OUTSIDE AIR DO DIGITAL OUIPUT OD OUTSIDE DIAMElER + r ~ DWH DOMESTIC WA 1ER HEAlER DWG DRA~NG p PRESSURE .. ox DIRECT EXPANSION PH PHASE {ELECIRICAL) PSI POUNDS PER SQUARE INCH 1-------1 EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE RA RETURN AIR ____.. FO EER ENERGY EfFICIENCY RAllO REV RE\ISIOM • F/S EF EXHAUST FAN RH RELATIVE HUMIDITY = ESP EXTERNAL STATIC PRESSURE RPM REVOLUTIONS PER MINUlE -'VIr ET EXPANSION TANK RTU ROOFTOP UNIT <D EWC ELECTRIC WATER COOLER SA SUPPLY AIR SEER SEASONAL ENERGY EfFIClENGY @ ' DEGREES FAHRENHm RATIO FC FORWARD CURVED TSP TOTAL STATIC PRESSURE ~ Feu FAN C<lL UNIT TU TERMINAL UNIT 0 ' r ' 63 IF TillS SIIBIIT IS NOO' 38' X 24", IT IS A REDUCBO PRJNr. SCALE ACCORDINCJLY r-----------------------------------------------------------~------------------------------------------------------------------~--------------------------~--------------------------------~ HVAC DESIGN DATA SUPPLY/EXHAUST FAN SCHEDULE GENERAL COOLING. HEATING MAX SONES ROOF (WALL) . 1SP IN W.G. WT. LBS DESIGN AND .LAYOUT BASED SPACE SPACE DESIGN GREENHECK MODEL NO. ALlllUDE CUMA1E TEMP. RELAliVE CONDiliONS ARE.A (Fl) ZONE D. B. HUMIDITY D.B. W.B. ('F) (ll) ('F) ('F) OCCUPIED SPACE 650 3A 75 3D-55 10D 78 tJQliS; SPACE SPACE DESIGN TEMP. RELATIVE CONDITIONS D. B. HUMIDITY D. B. ('F) (ll) ('F) 70 30-55 20 TAG EF-1 lliROUGH EF-4 EF-5 ~ 4.0 SERVICE TOILElS OPENING INCHES 200 0.5 0.5 .21 SP-A290 TYPE FC FC OP. HP 1. INTERLOCK 1111H UGHT 5\\1TCH \\11H 10 NINUltS nME DaAY. 5. FAN TO OPERAlE CONliNUQUSLY. 1. CUMA1E ZONE IS DEFINED BY ASHRAE 90.1 - 2004. AIR HANDLING UNIT SCHEDULE UNIT TAG AHU-1 AREA SER'I£0 MUNICIPAL COURT BLDG. SYSTEM TYPE VARIABLE AIR VOLUME MANUFAClURER MCQUAY MODEL NO. CAH025GDAC GENERAL SUPPLY AIRFLOW - CFM 10,700 EXTERNAL STAliC PRESSURE - IN. WG. 2.5 MINIMUM OUTDOOR AIRFLOW - CFM 1,710 ECONOMIZER - % N/A UNIT ·IIEIGHT - LBS. - VOLlS/PHASE 20B/3 ELECTRICAL MCA REQUIREMENTS MOCP . ' •" .,,, ,., . (;i4 IF THIS SliBBT IS NOT 38' X 24", lT IS A lUlllU® PRINT. . . . SCAU1 - -· AQCORDJNGLY . ,---------------------------------~----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------~ 1 g COURTYARD 8.9)----'- POLICE DEPARTMENT FACILITY 1 1h 1 j - 111'11 I 1~111 2 3 I 121'-0" ~-·1-·----·-·--·--·-----t"-----·----·--·----·--·l-. ~ I ' I I PRIVATE1 ENTRY MECHANICAL I YARD 5 6 1 \. I ~----- c--c----r--- IGI150 I TYP. OF 2 \ IGI 240 I TYP. OF 2 IGI200 I IGI170 I TYP. OF 2 '"~_, t-..l>.'\1\)i',\r-r---_,+-< 1CI - La·~ 1/1~ BjL,o_ - ---1 ( " . . r10"¢ I r)?J; (f) "~ "· ~/ // IAI2BO I " IQl - . r--' L 0 h IFFF-T~TYP;;c.· ~0;-'F 4 ~ CHIEF DEPUTY CLERK [ I , - _ ______>:''nlvn.R"i' ST; iC~ r . TIJ-1/Ft=r~='l - 10/1 10"¢ w . 8"~ OFFICE 8"¢ '---- - --- - --- - +11-I -t-- . I 1 .. :ul=10. . 11-----1 'II I 66 IF 'lHIS SIIBl!l' IS NOT 36' X 24", IT IS A RllDUCl!D PRINT. SCALE ACCORDINGLY ,-------~------------------------------------~------------------------------------------------------------------------------------------------------------------------------~------------~~~ <~ ( Cl z 0 lii > LIJ ~ ' d z '· ••· SA ., - / // '" / /r.·; ' ... ' r--.11 I .. 14/2&<>-SA . I 18/30<>SA <4 20/34-<>-SA. 24/3&<>-SA "" v 4--'\;--- 14/24-<>-SA- "-.., .24/# RA- ; r:; i ! li'· / ~ ~ ~ ~: ,, I< k: . ~ "" Alill=1 .. ,., t"-1 r& " w " w~ t"'\ r 1 ' BUILDING SECTION - HVAC '-.M70y SCALE: 1/4" - 1'-0" WC.!:J <CZ ~ ..... >W.<.c .J > J: 1-"'Ill ::- :> I w -1- 0 C/z ) 0:1-a: D.:.1- :a: Q > 0 C/w ) <C() C!'· ...J_J 0 z -u.<C :.-.:.> .1 oQ: 0 al >-z I::=> 0~ DATE: 05-09-08 DRAWN: JAE DESIGNED: SGA CHECKED: FCC PROJ. NO. 02-1139-01 SHEET: M701 · FII.E NAME: 021139M701.DWG· I I 6.8 IF THIS SIII!El' IS NO!' 36' X :lA", IT IS A REDUCIID PRINT. SCALE ACCJORDINGLY ,---------------------------------------------------------------~------------------------------------------------------------------------------------------------------------------------~~, 1 ··.-' FLOOR 3/4' MAKE-tiP WAIDi PROM BACKFLOW PREIDliDi. SEE DETAIL 2/ M3.1 3/4' ,.....-- CHEMICAL POT FEEDER FOR CHILLED WAIDi SYSTEM, MOUNT 3' A.F.F. MAX. 1/2' 1/2'- j -----PR0:>1DE HEAT TRACING PER DIRECTIONS ON DWG. J/4' S' TO BUILDING CHIU£0 WAIDi DISlRIBUTION SYSlEM ! ;:;:]... 3' r ~ --- - CH\\1l J~ -1'-!Jf- --1113. I .. CHI\S ---'---, L TO DRAIN CHYIP-1 '-------+- CHI\S ---;r--~J -J)J--t::;:H)f--1--' S' J FLOW METER ~ AUTOMATIC BALANCING 11 VALVE i I I L 6' CHANNEL 1 CHILLED WATER PIPING DIAGRAM MB02 SCALE: NOT TO SCALE 1/4' MANUAL AIR VENT llllH GLOBE VALVE---. AIRFLOW FLEXIBLE CONNECTION (TYPICAL)----rlf"--"'~~---+--+--' CONDENSATE DRAIN \\11H TRAP AS REQUIRED. PIPE TO FLOOR DRAIN ----------.. 1 /2' DRAIN BALL VALVE YjJH HOSE CONNECTION-------------' PIPE SIZE SCHEDULE UNIT COOUNG COIL AHU-1 2.0" ,------lHERMOMETER AND PRESSURE GAUGES ,------2-WAY MODULATING CONTROL VALVE ,---- AUTOMATIC FLOW CONTROL VALVE lllTHJN MINIMUM 4 PIPE DIAMETERS DISTANCE TO OlHER ATTINGS RETURN '----BALL VALVE \'jJH EXTENSION BEYOND INSULATION, (TYP.) SUPPLY I'IQlES; 1. \'jHERE PIPE SIZE IS 2 1/2' OR SMALLER, PRO\!IDE BALL VALVE IN UEU OF BUmRFLY VALVE. J . ' ' ·;, ., IF TillS Slll!l!l' IS Nm' 38' X 24", IT IS A RllDUCliD PRINT. . SCAUl ACCORDINGLY ~----------------~--------------------------------~------------------------------------------------------------------------------------------------~--------------------------~----------~ .·; -. AO - MIXED AIR DAMPERS AI - DA lEMP SENSOR ..,---'TjL--- ~L­ OA > N.C. u_ . " N.D. H L Bl - RETURN AIR SMOKE DETECTOR AI - RETURN AIR RELATIVE HUMIDITY AI - RETURN AIR C02 PPM AI - RETURN AIR IDIP s _{ RH C02() _(T ~ RA Bl - FlNAL ALTER DIFFERENTIAL PRESSURE AI -'MIXED AIR TEMP Bl - FREE2£STAT I (r) [T AO - HEATER ENABl£ HEAlERU STARTER N.c. AO- COOUNG VALVE-Ill\. k . ""', ('- c. CHWR+----' CHVIS---" ! Bl - SUPPLY FAN STATUS "r" I VFD I II BO - SUPPLY FAN START f.STOP AD- SUPPLY FAN VFD SPEED 81 - SUPPLY FAN VFD FAULT '1" AHU-1 CONTROL DIAGRAM SCALE: NOT TO SCALE AD - ZONE DAMPER AI - AIR FLOW AI - DISCHARGE AIR TEMP ) J,l)_ T) AI - SUPPLY AIR TEMP Bl - HIGH STATIC SHUTOOYI!l (f) H L I f f SA 2_ "" ill DA AI - ZONE 1EMP El£CTRIC RESISTANCE COIL AO - HEATER ENABl£ HEATER STARTER VAV AIR TERMINAL UNIT CONTROL DIAGRAM SCALE: NOT TO SCALE -AI - SUPPLY AIR STATIC PRESSURE H L ' ·' ' . 7.1 IF 'lliiS SBI!EI' IS N!JI' 3fi' X 24", Ir IS A REDUCED PJIINT. SC'ALll ACCORDJN'GLY ------------------------------------------~--------------------------~----------------------------~~ I ' I ' ~ . ~~ ~ i i i j ! j I I I ~ ~~f!o~~~" 'ru"'E§C~F: 6.~1 1~. we i ! ! ! 1 ! j . 1 i ) j ,~\-11-JMG~ ,.--,, 546 . j I I I I ' I ( I 12".J GENERATOR I i i ' ' ! i !· i - i ,. ::.=_----- -----,r--___ - ;:-:-==1== r---,=-=- '==+=·-=· '=--=t=-·=-= ----··---r·=·-=- ==+f-=·-=· :===t===, 1 ·,=·-=r:== ~=!=-==~---- FdR CONT. A 1 r---+!1 ' I :> MECHANICAL* CIVIL : I ' I i I 'II PRIVATE I ) r-.... YARD • n ~· ~ I I ' I ' I ' I I ' I ' ' I I I ' I ' ' I _I . ' I ' I I I I I I ' I I I I I I I I I > I < I I . ' I I ' I ' ' I I ' I ,. ., •'· ,:.... '~. 72 IF 'IBIS SBEllT IS NO!' 3S' X 24•, IT IS A REDUCED PRINT. 5CAUl ACCORll!NGLY ,.. -----------------------------------------------------------------------------------------------------------------------------------------------~----------------------------------------------~· ' r 3 *"N1~-1 l v - - -+1+- - -f--1--+·( ~ 2Ji" VERTleAk 9CBP - -- - -- - - W '-f- ['CY I I ,_3 • ____ J -~-~3~ __ ! _______ , nWH-: _ MEQHANo. 41£~_-. L ROOM II ( \A t ' ./ ' ,17-r-1- c f--4"EC::2. I I H" W/~ TPD D G ..10..- .--'".-- . W/lPD I I ---t+ - · - -ss 4 • ·j--. . ~ ., HWCP-1 . 3• YJR- ~~·J~ I I 4., ·. I 4"rn-~ -~~ 1 . !t-1" : W/TP'l'1~4 • I . - - I::::::::=========::JL.. -o 4"FCo--2 / 1' ENLARGED PARTIAL PLAN - PLUMBING ,pso1 ...._ _ __.. scALE: 11 4" - 1' -o· -, 2 ENLARGED PARTIAL PLAN :.. PLUMBING P601 SCALE: 1/4" - 1'-o· -~~- +i- ---- --:r-r- - -- - -- +-'R-iA. 9 2"- •. ~ MEN'S I< ~ )J ~ ~we ~ 2 -H-1 --AJ-l-\ .!..RR l.ss-4-::':lY.ll"C=".f 2. --...J+....I 1 ss -:2':"13"r "Jr+-l-rll++t- 4"'l!B.~ 1 rt=~~r 1!::l. ~ . t®r------- - 3"ill=l. 1 3"1:--:- 3"El2=1. W/lPD . 3".f J ,j~OME~ I Ld. 1--0-'-'-b'-'-i '-'· 0-~·· R R / 1 3 ENLARGED PARTIAL PLAN - PLUMBING '.- P60~ SCALE: 1/4" = 1'-0" ! ! I I ! I=<( ! 0 z 0 (ij > w 0::: ci z 0 .. ',l . ' . ' '. <' ' 73 ."i)' ' WASTE AND VENT RISER DIAGRAM @ 2£:~~STIC WATER RISER DIAGRAM SCALE: NTS SCALE: NTS WASTE AND VENT RISER DIAGRAM /4' DOMESTIC WATER RISER DIAGRAM SCALE: NTS IF 'IHIS SIIEEI' IS NUl' 36' X 24", IT IS A REDUCJ!D PRINT. SCALE ACCIORDINGLY . i i d z m (-z !} ~ ;:) ...1 0.. I (f) 0: w (-a: f) DATE: DRAWN: DESIGNED: CHECKED: PROJ. NO. SHEET: (f)(.D x- <we CZ t-::::::1 :> b:u..jal l- o!a.S o <Co ............ LL<( oQ: >t-z (- .) _:::> (.)~ 01-10-08 LDM LDM TSB 02-1139-01 P701 I .. I ., ..I , •• •.. ., ' 75 IF 'IBIS SIII!EI' IS NOT 36' X 24", IT I!i A REDUCED PRINT. SCALI! ACCORI.JINOLY ,-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------~ I ' I ' i i i i ! I I I j j i i ! ' . i i i i ! I I I l I I I I . 1 ' I I I I ' ' I ~~ I I ' I~ j( 1-1----------- - ==:r=-=-=-- r-=-==i==-::-:.:. : -=-=-·=+==-=- o ==+===~I =-::--_.=r== I-=-=t== -_---_,f------- I=·=+== f-- l I NOTES BY SYMBOL 0 NOTE DESCRIPliDN 1. LIGHT HAZARD OCCUPANCY IN THIS AREA. MINIMUM DESIGN SHALL BE 0.10 GPM/ SQ.FT. OVER 1500 SQ. FT. HOSE ALLOWANCE SHALL BE 100 GPM. QUICK RESPONSE SPRINKLER HEADS SHALL BE UTILIZED SPRINKLER HEAD lEMPERAWRE SHALL BE 165 DEGREE F. '~ I -- - -- --- (: <D -- PRIVATE ENTRY y I ' I ' I ' I ' me_• I@ ' ' V F8.Cl1 I ' I I ' I I I I ' I o p.--.I 1• I I I I I I I I I I I 1 I I I I I o I I J I 1/ 1 '\ FOR 1 1 1 1 I~ ~~~ JHI ! ! ! ! .ts' . I I I ~~-~-~~--!H~~~~~:~-~::·-~~-~~~I-+~-~-~~-~-~~i:~~~~~~~~~~~~Im~~-~-~~==~~----------~---~ Q) "~'"~~ . '"----@ ll ELECTRICAL !::.., ® r----------T~:=-=-=~~~~------!1 ----1-----------j IN. ~ELE/ 1 MECHANICAL ROOM n : 1m DATA I r=: I I !)'---'==Q)=~1 '(""""-_,!~---------~ ' i - - ! \ I ~~ ~ ( ••~COmRR0ID00R~~~~ ====F=========~==~~ ~/====±=======~==F: ==~~~--~ I 'WOMEN'S '""' ' i ( ') : RR · 1U ,., UNISEX It! RR ® ' I 2. ORDINARY HAZARD GROUP 1 OCCUPANCY IN THIS AREA. MINIMUM DESIGN SHALL BE 0.15 GPM/SQ. FT. OVER 1500 SQ. FT. HOSE ALLOWANCE SHALL BE 250 GPM. QUICK RESPONSE SPRINKLER HEADS SHALL BE UTILIZED SPRINKLER HEAD TEMPERAWRE SHALL BE 165 DEGREE F. BREAK ROOM im\©11 ~ <D llJ .©l I~ \.__ I I : I ' : I GENERAL NOTES NOTE DESCRIPTION 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 o. THE MUNCIPAL COURT BUILDING SHALL BE FULLY SPRINKLED AS SHOWN. ON DRAWING. DESIGN AND PROVIDE A WET PIPE AND DRY PIPE AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE ~TH NFPA 13-2007, AND NFPA 24--20D7. IN ADDITION, FIRE PROTECTION WORK SHALL BE IN ACCORDANCE WITH THE "AUTiiORITY HAVING JURISDICTION" WHICH INCLUDES THE CITY OF LA PORTE, TEXAS AND THE REQUIREMENTS OF OWNER'S INSURANCE UNDERWRITER. PROVE AND HYDRAULICALLY CALCULATE THE MOST REMOTE AREA OF THE AUTOMATIC SPRINKLER SYSTEM BASED ON THE FLOW TEST DATA OF 54 PSI STATIC PRESSURE, 38 PSI RESIDUAL PRESSURE AT THE EXISTING FIRE HYDRANT ON THE 8" MAIN AT N. 23RD ST. IN FRONT OF THE CITY OF LAPORTE'S PUBLIC WORKS BUILDING N. E. CORNER OF NEW POLICE STATION WITH 1006 GPM FLOWING 8" MAIN. CALCULATE BACK TO THE POINT OF THE PRESSURE TESTED FIRE HYDRANT ON THE B" SITE CITY WATER MAIN. SPRINKLER ZONES ARE INDICATED ON THE DRAWINGS. BASE CALCULATIONS ON THE OCCUPANCY REQUIREMENTS OF NFPA 13 AND THE "AUTHORITY HAVING JURISDICTION" AND AS NOTED ON THE DRAWING. PROVIDE AN ADDED HOSE ALLOWANCE AS NOTED ON THE DRA~NG AT THE POINT OF CONNECTION TO THE CITY SITE WATER MAIN. CALCULATIONS SHALL INCLUDE A 10 PSI SAFETY FACTOR ON THE DEMAND. SEE SITE UTILITIES DRAWINGS FOR PRESSURE TESTED FIRE HYDRANT LOCATION. CONCEAL PIPING ABOVE CEILINGS AND PROVIDE WHITE PAINTED POP-OFF COVER-CONCEALED TYPE PENDENT SPRINKLER HEADS IN CEILINGS LESS THAN 9'~0" ABOVE FINISHED FLOOR. WHERE CEIUNGS ARE 9' -0" OR GREA TIER ABOVE FINISHED FLOOR PROVIDE WHITE PAINTED LOW-PROFILE, SEMI-RECESSED TYPE SPRINKLER HEADS. IN AREAS ~TH NO CEILINGS RUN PIPING AS HIGH AS POSSIBLE AND PROVDE BRASS UPRIGHT TYPE SPRINKLER HEADS. NON-CONCEALED SPRINKLER HEADS 8' -o• OR LESS ABOVE FINISHED FLOOR SHALL BE PROVIDED WITH HEAD GUARDS. SPRINKLER HEADS SHALL BE QUICK RESPONSE. PROVIDE DRAINS AND INSPECTORS TEST STATIONS TO COMPLETELY DRAIN AND TEST ALL ZONES. INSPECTORS TEST STATIONS SHALL BE LOCATED IN NON-OCCUPPIED AREAS TO THE ACCEPTANCE OF THE OWNERS REPRESENTATIVE. PROVIDE ACCESS PANELS FOR VALVES AND FLOW S~TCHES LOCATED IN INACCESSIBLE CEILINGS, WALLS AND SPACES. MAKE ALL NECESSARY OFFSETS FOR ARCHITECWRAL, STRUCWRAL AND MECHANICAL FEATURES OF THE BUILDING WHERE NECESSARY TO ACCOMPUSH THE WORK AS INDICA TED. ALL EXTERIOR EXPOSED MATERIALS SHALL BE CHROME PLATED. CONTRACTOR SHALL PROVIDE "RECORD DRAWINGS" AT END OF INSTALLATION. WHEN PENETRATING FIRE RATED ENCLOSURE, PROVIDE FIRE RATED SEALS AROUND PENETRATIONS EQUAL TO THE FIRE RATING OF THAT ENCLOSURE. SEE ARCHITECWRAL FIRE PROTECTION DRA~NGS FOR FIRE. RATED ENCLOSURE LOCA liONS. FIR.E PROTECTION VALVES SHALL BE PROVIDED WITH SUPERVISORY SWITCHES AND CIRCUITED INTO THE FIRE ALARM SYSTEM. AU TOM A TIC SPRINKLER SYSTEMS AND ZONES SHALL BE PROVIDED Willi FLOW S~TCHES AND CIRCUITED INTO THE FIRE ALARM SYSTEM. 11. PIPING SHALL BE CONCEALED IN WALLS, CEILINGS, SOFFITS AND FURR-OUTS UNLESS OTHER~SE NOTED OR IN MECHANICAL ROOMS OR OPEN AREAS. . 12. PROVIDE FIRE DEPARTMENT CO.~NEC110NS IN ACCORDANCE 'I,~TH THE- AUTHORITY HAVING JURISDICTION LEGEND SYMBOL DESCRIPTION ABBREV. -FW- FIRE WATER FW -AS- AUTOMATIC SPRINKLER AS --FDC- FIRE DEPARTMENT CONNECTION FDC -L SUPERVISED SHUT-OFF VALVE --l)l - HAZARD FLOW SWITCH BOUNDRY POLICE DEPARTMENT FACILITY I I I ' I I I ' I I ' I I I ' I ' I cb- I I CHIEF DEPU1Y CLERK I / I ' i <D : "- '---- iAw JV'" STA N ! I r I I 0 r1\ : I ' I I ! I ' I I I I I I I I : I I I I COURTROOM I I 1 r I I I FILE/ STORAGE ROOM ' I I I I ' I I I Lf-1 - =+---- --- - 'H--- ----F~~===-~---¢-~~-=---=----=--:.-=----=---__/--------0 ' _ __:_:::_::_:_~~_,_·1--,--,-,,-----JU~ ~~N's©J1 It© / (_ ) Ill ~ -' <D JUDGE'S OFFICE ~ DEPUTY COURT CLERK I )KK ( \.__ H.C. I~\__ <D I ill I ~ lt'1 ov D I Y ""' RR f ~@ I ~ JURY/ CONFERENCE ROOM I I I ~~ LOBBY BALIFF LA PROSECUTOR'S OFFICE ----- . -. I I PORTE COCHERE I I I I I o ~~-I -----~---------~-------~ I i o I ' I I I I I I I I I I ' I I ' I I I I I I I I I I : I I I ' I I I r I ' I I I I I I I I ' ' ' I I I ______________ ___/ ,~-~ -§ -------------------------~ 2 ~ cb 4 0 0 ~0 1 FIRST FLOOR - FIRE PROTECTION '-- f4Dy SCALE: 1/B" - 1'-0" 1!:! c <( d z z 0 i= 0 w 1- 0 a: Q.. " w LL I Cl) w 1- 0 z c z <( ci ifi (w !:' .z .J. - <( ..J Q.. a: 0 0 ..J LL DATE: DRAWN: DESIGNED: CHECKED: (f.)<!' <Cz X£5 W...J 1-::- :> w-m 1-1- a:a: 0::> D..Q <_. ((.....) . u..<C oQ: 1:>::-::(z :.> ) 0~ 01-10-08 LDM LDM TSB PROJ. NO. 02-1139-01 SHEET: F401 ALE NAME: 021139F401.DWG :> <z:( ·. I z <( ...1 0.. ...1 <( <~ ( 0.. (a: <fa !:( ' .z w ..1 (/)(.!:' x- <wc CZ ..J 1-5 ujCC 1-t- -~~ D..Q <C ·o ..J..J u..<C oS: 0 1->_::-:z > - ()~ \...._ ___ __.I DATE: 01-10-08 DRAWN: LDM DESIGNED: LDM CHECKED: TSB PROJ. NO. 02-1139-01 SHEET: P601 I ' ' I ' I I I I ' ' I I ' I I I ' I ' ' ' J--~='=~ ' j=::==~=::::::= '':==~=:=:·-·=:t==:==~=::= ~-~~~ F ~ - - .l ENTRY I \ r- -r- _r ... ;;;,,V.,;;. ·f--- I . I 1 9~----_// I ,----------,~:--- 1-------li+----t-----------.., ·+ -- - ±- 1-- ,·' ,, '• ~"NWJH • WORK ROOM ~ n•~~/ ' MECHANICAL ROOM : I 1--- j] : I STORAGE r~~ 1 : r=: 4"1.'/m f/ 4;;s;,; ' I i i I 2" ~tt~ ! i i i i f ,,, ::..: •§3 " CORRIDOR \._ : ' > ' . II~======~~~ ~l ~--·-T ~· ========~~~~~~========~==\~ / . \ . """r'i'~ llfl ['j UNISEX I I 1 1 '-........ • ,.,. I IIRR I"" .... RR : -z - ) ~0~)~ ' I i BREAK \ 1 ,. · I ~ @:l liD · [ , l>=1: I~ ~· i ) \___ : I "'" V ""'" hf'l FILE/ STORAGE ROOM 1 741- [i ~ E I ' JUDGE'S . OFFICE ; • • • ' / 4"- / ! I I I i I j ' . I I : I I ' I ' : COURTROOM I I I -OUI '~ / VALVE (r!P) __ I COURTYARD I &------------, . . ~AliFF i . "------------- H- I D D D . D D D D D D D D D ~-D D D -0 / D r;JB EtE3Etf L.JJ LJ::i1"1 '-'B"E:. tt. ~:t-.1 ~:::t.~•' El ffi LJ~::=::::::=::::::=::::=;:;~==="""""'f=='fi ------ POLICE DEPARTMENT FACILITY I I ' I ' I ' I ' I ' I ' I ' I I ' I I 2 / 1' FIRST FLOOR - PLUMBING .\ P40~ SCALE: 1/8" - 1' -0" ' I II I. 'i II I. I. 'I I 'I , il ~-0 - _______ ___f/;,\ . --------.._ -----vv . '"----@ i ! . i ' ' }!:! 0 < z 0 (ij IJJ > 0:: • 0 z I z <( ~ a: 0 0 ..J LL CIJ(!' . x- wc <CZ ..J 1-::- J w -aJ 1-1- a:a:: 0::::> D..Q <(() ........ u..<( oQ: 1->_::-:(:z > - ) ()~ DATE: 01-10-08 DRAWN: LDM DESIGNED: LDM CHECKED: TSB · PROJ. NO. 02-1139-01 SHEET: P401 ALE NAME:: 0211.39M401.DW.:> --' __ __, LOCAlE 3/4 DISTANCE DOWN LONGEST DUCT SA BO - CHD.LED WATER PUMP 1 START STOP . 81 - CHILl£0 WATER PUMP 1 STATUS AI - CHILl£0 WATER RETURN TEMP i T CHWR '-.::V ... v 1\ CHIIP-Z 1- ~ ( CP AI- KW I Bl - CHILl£0 WATER PUMP 2 STATUS FHilllRI I BO - CHILJ.ER ENABLE !sr BO - CHILl£0 WATER PUMP 2 START f. Bl - CHILJ.ER STATUS ~ CHVIS AI - FLOW ME1ER AI - CHILl£0 WATER SUPPLY TEMP z -... 2' CHLLED.WATER CONTROL DIAGRAM - M901 SCALE: NOT TO SCALE z 0 ii) 5 IJJ 0::: 0 z I~ I~~,i ~ ~ I( iP IIi' §!I . :~if~ 2 ~3:~ (/)(!) 0 <C . - ·-x- <we . ·. z ...J :> I: 1-5 I w ""al C/) 1-t- :<E C ---~s a: C) - <c C a.<(.(o .) ....1 ...J_.J 0 a: u..< 1- z oQ: 0 (.) 0 1->-z - _:::::> (.)~ DATE: 05-09-08 DRAWN: JAE DESIGNED: SGA CHECKED: FCC PROJ. NO. 02-1139-01 SHEET:· M901 ALE NAME: 021139f..t901.DWG · 2. PRO\!IDE lHERMDMETERS AND PRESSURE GAUGES PER SPECS. J. INSTALL UNIONS IN PIPE LOGA TION OUT OF WAY TO PULL COIL OUT. '-----STRAINER 4. PRO\!IOE BALANCE METER IN lHE SUPPLY HE.A TING COIL . PIPE FOR AHU COIL YjJH 50 GPM OR MORE. 5. PRO\!IOE BALL DRAIN VALVE \'jTH HOSE · ADAPTER AND CAP. 2' AHU COIL CONNCECTIONS \_MB03; SCALE: NOT TO SCALE ~ M601 AND CHILLER FREEZE PROTECTION PER..._ ____ MANUFACTURER'S RECOMMENDATIONS - BUND FLANGED BUmRFLY VALVES FOR CONNECTION OF EMERGENCY CHILLER 6' HIGH CONCRETE PAD >1BRATION ELMINATOR FLOW S\\1TOH AIR VENT NOTES BY SYMBOL o (lHIS DRA\IlNG ONLY) NOTE DESCRIPTION 1 AIR-COOLED PACKAGED CHILLER ASSEMBLY MOUNTED ON 6' HIGH CONCRETE PAD \\11H TOP LEVEL SEE DWG M601. 2 1EMPERA1URE AND PRESSURE 'PETE'S PLUG' \\11H CHAIN AND CAP. 3 LOW PRESSURE DROP, UNE SIZE AIR SEPARATOR \11TH SYSlEM STRAINER, BELL & GOSSffi MODEL R-3. 4 3/4' BALL VALVE 1111H B&G N0.107A HIGH CAPACITY AIR VENT HA\!ING 180 DEGREE TUBE TURN ON 3/B' OUTLET. 5 CHILLED WATER PUMP ASSEMBLY CHWP-1. SEE DETAIL 7 /MB01. 6 NORMALLY O.OSED 3/4' HOSE-END GLOBE DRAIN VALVE l'jJH NIPPLE, CHAIN & CAP. (TYPICAL) . 7 SECURELY SUPPORTED FROM STRUClURE AND INSULATED A.S.N.E. STAMPED, PRE-CHARGED TO 12.8 PSIG, DIAPHRAGM TYPE EXPANSION TANK (ET-1) SEE SCHEDULED DATA ON DWG. M101. 8 FLANGE SIZE BY MINIMUM OF 18" LENGlH OF FLEXIBLE, INSULA TED PIPING CONNECTIONS TO CHILLER UNIT. 9 CAPACITY PER A.S.M.E. BPV-\'111 DIV. 1 AND STAMPED TEMPERAlURE AND/OR PRESSURE RELEF VALVE AS APPUCABLE 1111H DISCHARGE PIPED TO 3 INCHES ABOVE ANISHED FLOOR. 10 AD..IJSTABLE PIPE SADDLE SUPPORT \\11H U-BOLT EQUAL TO B-UNE MODEL B3D90 1111H BASE STANO EQUAL TO B-UNE MODEL 83088 ANCHORED TO CONCRETE PAVEMENT \11TH (4) J!i CONCRETE ANCHORS. El.ECTRD-PLATE ALL MATERIALS. 11 PIPE SUPPORT STRUT MOUNTED TO WALL EQUAL TO B-UNE MODEL B-22 1111H PIPE CLAMP EQUAL TO 8-UNE MODEL 82400. 12 120 GALLONS PREINSULATED CHIU£0 WATER STORAGE TANK. SEE ORA\\1NG M601. - - - -!If- -, IH I 4' MIN. GROUND 6' HIGH CONCRETE PAD _, \ ~ <( 0 z 0 iii 5 LLI 0:: d z ~~,t ~ <;I E~~ i il~ ~ i - (/)(!) (.) <(z > <( .xa w._. J: 1:-- I .. :Ol :::> (/) w ~ ........ <a: ( a: a: (-c <!( ) 0:a.::o :> c <(() z ......... (-<<_/. ) ( ( oS: u..<() ( 1- w c .>__::-::z > - ()~ DATE: 05-09-08 DRAWN: JAE DESIGNED: SGA CHECKED: FCC PROJ. NO. 02-1139-01 SHEET: M802 I--IP\1~'~~1o~·~-+-<l~2o/14 I'' ~ I 1310 I TYP. OF 6 ~ I\.__ I,' 10"~ ' I <::"' ~ !~==~='=='====~~======~===~ ~ t 10 I ( K <_p ! .. 1o·~ , I'' ~ I I I 1." . 10"~ _, I ,,. I L .10"~ I I" ~ I I ... 10 r.n1 M .~ (I r UUI I " ·~ -- L ____ _ IG 190 '!Yf-. OF 3 I r---- I ~' 1 FIRST FLOOR - HVAC . '\..M401 - SCALE: 1/8" - 1'-0" -----, I 7 -- , 10' AJ ~ ,.,T : v ~ .-,\/;.\V"TVO '· 10/14 ' 16/14--1 ' 10' A. I I I 10"¢ AAI ~ 'VT LQIJ1Q I TYP. OF 6 I I 10"¢ AAI c .. , I • 0 ""I ' ' 1-- NOTES BY SYMBOL 0 (FOR DRAWING M401 ONLY) NOTE DESCRIPTION 1 SPACE lEMPERAlURE SENSOR AND CARBON DIOXIDE {C02) SENSOR, WHERE INDJCA'IEO, MOUN'IEO 48" IfF 10 CONlROL CORRESPONDING AIR 1ERMINAL UNIT. 2 CEIUNG-MOUNTEO SUPPLY AIR DIFFUSER. 3 24/12 ACOUSllCALLY INSULA'IEO lRANSFER AIR DUCT. SIMILAR TO DETAIL 6JMB01. 4 CEIUNG MOUN'IEO RElURN AIR GRIU.E Of 1HE iYPE INDICAiED 11m1 SOUND BOOT. SEE DETAIL 6JM801. 5 ACOUSTICALLY INSULA1ED RElURN AIR INTAKE DUCT v.llH 3/4" MESH SCREEN AT OPEN ENO. 6 RElURN AIR lRANSFEli GRIUE ON B01H SIDES OF FULL HEIGHT WALL ABOVE CEIUNG v.llH TYPE AND SIZE INDICA1ED. 7 SIDEWALL SUPPLY AIR GRIUE OF lliE TYPE AND SIZE INDICA1ED. 8 LINEAR SLOT AIR D!SlRIBUTION llE'IlCE Of 1HE TYPE INDICA TEO AT CEIUNG SOFFIT, v.llli 6 FOOT LONG SUPPLY SECTION A1.1ERNA1ED v.llH 2 FEET LONG BLANKED-Off SECTION. PROVIDE INSULA1ED EXTENDED NECK PUENUM AT DIFFUSER. SEE DETAIL 2/MS01. 9 SINGLE DUCT AIR 1ERMINA1. UNIT v.llH ELEClRIC REHEAT COIL SUSPENDED FROM SlRUClURE ABOVE CEIUNG. SEE DETAIL 6/MBOI. 10 . 3/4' UNDERCUT DOOR. 11 4 fOOT LONG UNEAR SLOT AIR D!S1RIBUTION Of 1HE TYPE INDICA1ED INSTALLED AT LAY-IN CEIUNG. COORDINATE ANISH AND COLOR MlH AIRCHITECT. SEE DETAIL 2/MBDl. 12 DUCT MOUN'IEO PRESSURE DiffERENTIAl. SENSOR FOR AIR HANDUNG UNIT FAN SPEED CONlROL REFER 10 SEQUENCE Of OPERATION SPECIACATION SECTION FOR DETAILS. 13 CEIUNG MOUN'IEO TD!UET EXHAUST FAN IN1ERLOCKED v.llH 1HE UGHT Sv.lTCH. 14 BLANKED-Off CORNER SECTION Of UNEAR SLOT SECTION. AELD VERIFY EXACT . UENGTH. COORDINATE FINISH AND COLOR v.llH ARCHITECT. . 15 6 FOOT LONG RElURN AIR UNEAR SLOT SECTION OF 1HE TYPE INDICA'IEO. COORDINATE FINISH AND COLOR MlH ARCHITECT. 16 24/24 RE1URN AIR GRIUE CONNEC'IEO 10 12/10 lRANSFER AIR DUCTWORK I I I i ' ' j ~ <( Cl z 0 en 5 a:lJJ : c , 0 z ·'--"· ''.- -- ... ---·-·-· · .. - I z ~ a: 0 0 ...J LL. UJC!<z ) 1-xes w :::. :! I :::> w ""al 1-1- a:a: 0:::> a.o <((..) u.-l...< J o9:>-(z ..: ) !::::::> .0 ::1E DATE: 05-09-08 DRAWN: . JAE DESIGNED: SGA · CHECKED: FCC PROJ. NO. 02-1139-01 SHEET: M401 AIRFLOW - CFM 10,700 TOTAL STATIC PRESSURE - IN. WG. 4.5 SUPPLY HORSEPO\Il:R 15.0 FAN RPM 1,604 FAN TYPE AIRFOIL SPEEO CONTROL VARIABLE SENSIBLE CAPACITY - MBH 339.9 LATEMT CAPACITY -.MBH 136.B IDTAL CAPACITY - MBH 478.7 EAT DB/liB - 'F 80.5166.2 LAT DB/liB - 'F 51.4151.2 CODUNG AIRFLOW - CFM 10,700 COIL MAX. . FACE VELOCITY - FPM 439.0 MIN. NO. ROWS/MAX. FINS PER INCH 6/10 WATER FLOW - GPM 78.5 MAX. WATER PRESSURE DROP - FEET 4.3 EWT- 'F 42.0 LWT- 'F 54.1 MINIMUM HEAliNG CAPACITY- KW 20 ELECTRIC NUMBER OF STAGES 4 RESISTANCE AIRFLOW - CFM 3,350 HEAliNG COIL VOLlS/PHASE 208/3 MCA 69.4 FLA 55.6 FUSE 85.0 EAT/LAT- 'F 44.4/55.0 TYPE 4" PLEAn:D, 85% EFF. ALTERS MAx. FACE VELOCITY - FPM SOD NOTES 1,2,3,4 NOlES: 1. PROVIDE MOIDR STARTER, DISCONNECT S\\1TCH, CONVENIENCE OUTLET AND lHERMAL OVERLOAD PROlECTION. 2. FACTORY INSTALLEO ELECTRIC RESISTANCE HEAliNG COIL, DELL CQRP. MODEL NO. MM1-60x86-2D-208-3-2. PROVIDE SEPARA1E POINT OF POWER CONNECTION FOR ELECTRIC RESISTANCE HEATING COIL WllH DISCONNECT S\\1TCH. DIFFUSER AND GRILLE DESlGNA liON 'A' 'B' 'C' 'D' 24"x24" 12"x12" 24"x24" 24"x12' DESCRIPTION FACE SIZE CEIUNG FACE SIZE CEIUNG FACE SIZE EGGCRA1E FACE SIZE EGGCRA1E DIFFUSER DIFFUSER RETURN/EXHAUST AIR RETURN/EXHAUST AIR GRILLE GRIUE MAX. CFM NECK DIA. MAx. CFM NECK DIA. MAX. CFM NECK SlZE MAX. CFM NEGK SIZE 100 s• 60 5' 1,300 24"x24" 700 24"x12" 200 a· 100 6' 290 10' 200 8" 500 12' 750 14' 1,100 16' VOLUME CONTROL - - - - MAX. NC 30 30 - MANUFAClURER lllUS TilUS lllUS TilUS MllDEL 1M5-M lMS-M 50F 50F REMARKS 1-4 1-4 . 1,3 1,3 NOlES: 1. lHE BORDER 1YPE OF AIR DISTRIBU110N DEVICES SHALL MATCH lHE CEIUNG \\11HIN \\1iiCH IT IS BEING MOUNn:D. SCHEDULE ··r . 'F' CEIUNG/SIDEWALI. CEIUNG/SIDEWALI. SUPPLY AIR GRIUE RElURN/EXliAUST AIR GRILLE MAX. CFM NECK SIZE MAX. CFM NECK SIZE 790 18"x12' 120 12"x6' 3DO 12"xa' 375 12"x10" 200 1D"xB" 3,800 48"x1B" 120 s"xs· 500 14"x10" 500 12'x10" 1,200 30"x12" 1,800 4B"x12" ADC - 30 - lllUS lllUS 272-RS 35D-RL 1,3,5,6 1,3,5,6" 2. PROV.DE MOTOR 1\TIH lHERMAL OVERLOAD PROlECnON. 3. PROV.DE FAN 1111H ISOLAliON KIT, DESIGNER GRill£ AND PITCHED ROOF CAP EQUAL TO GREENHECK MODEL RJD-6x9 4. PROVIDE ROIJNO DUCT ADAPTER. ·' " 'G' 'H' lWO 314".- SLOT TWO 3/4" - SLOT SPACING 11101H UNEAR SPACING \\1D1H UNEAR . SLOT SUPPLY DIFFUSER, RETURN GRILLE, 6 FEET 6 FEET LONG LONG MAX. CFM NECK SIZE MAX. CFM NECK SIZE - - - - 320 60"Xl.75" 480 60"x3.75' 240 48"x3.75" ADC - 30 - lllUS lllUS ML-3B MLR-3B 1,3,6,7 1,6 2. RUNOUT DUCT SIZE IS lHE SAME CLEAR AREA SIZE AS 1HE NECK SIZE OF AIR DISTRIBUliON DEVICE, UNLESS NOn:D 01HER\\1SE. ANY OF 1HE ABOVE ROUND Fl.£l(IBLE (MAX. 5') OR METAL DUClS CAN BE PUSHEG INID AN OVAL CONFIGURAliON, 'MlERE NEEDED, PROVIDED NET CLEAR INSIDE AREA IS MAINTAINED. 3. PROVIDE MANUAL VOLUME DAMPER \\11H LOOONG QUADRANT AT EACH TAKE-OFF 10 AIR DISTRIBUliON DEVICES MOUNn:D AT LAY-IN TYPE CEIUNG AND EXPOSED DUCTWORK APPUCAliONS. PROVIDE DPPOSED BLADE VOLUME DAMPER AT GYPBOARD CEIUNG APPUCAliONS. 4. lOP OF DIFFUSER 10 BE INSULAn:D WllH VAPOR BARRIER. - 5. PROVIDE VOLUME EXTRACIDR FOR SUPPLY/RETURN AIR GRILLES AT RECTANGULAR DUCT INSTALLAliON APPUCAliONS. 6. VERIFY GRILLE SIZE PER PLANs; 7. PROVIDE Mln:REO CORNERS AS REDUIREi> AND 'EXn:NOED NECK'" INSULAn:D PLENUM 10 ACCOMMOOATE CEIUNG CONFIGURAliON, EQUAL TO OONCO AIR DISTRIBUliON EQUIPMENT COMPANY MODEL DWG. NO. CD-729. PROVIDE DIFFUSER \\1lll VERTICAL AND HORIZONTAL PATIERN CONTROLLER. PACKAGED AIR-,COOLED DUAL CIRCUITED CHILLER SCHEDULE WATER & MINIMUM ELECTRICAL DATA AT 460 VOL1S/3PHI60HZ ENT. SOL LVG. SOL FLOW PRESSURE ETHYLENE GLYCOL MINIMUM CAPACITY EFACIENCY OPER. WT. OUTDOOR FAN IDTAL PER UNIT TAG CAPACITY AMBIENT MCA PER MOCP 'F 'F GPM DROP (Fl) GLYCOL% VOLUME TONS STEPS COP IPLV LBS. 1EMP. 'F CKT. PER CRT FLA (EA.) KW (TOTAL) MCA MOCP GAL CH-1 54 42 87.2 7.3 - - 3 2.8 3.05 4,435 105 131 175 1.B 5.4 248 300 .timES;_ 1. COORDINAlE \\11H SPECIRCAliON REQUIREMENlS AND OlHER TRADES. 2. DESIGN AND LAYOUT BASED ON McQUAY COMPANY· AIR-COOLED SCROLL DUAL CIRCUITED CHILUER MODEL AGZ050C IM1H R-41DA REFRIGERANT. · 3. MANUFACTURER TO PROV.DE A SINGlE PCINT OF ELECTRIC PO\Il:R CONNECnON TO CHILUER AND CONTROLS COMPA11Bl£ \\11H BUILDING CONlROL SYSlEM. 4. lHE CHD.JfR EFACIENCIES INDICATED \\11HIN SCHEDULE ARE lliE MINIMUM EFRCIENCIES REQUIRED BY ASHRAE 90.1-2004. 5. ·PRO\olDE LOW AMBIENT CONTROL KIT FOR OPERAliON DO\\Il TO 10'F AND A HAIL GUARD. CIRCULATING PUMP SCHEDULE IMPELLER MOTOR TAG SER~CE FLUID GPM PUMP :;: EFF. TYPE DIAMrnR VOLlS/ I\EIGHT DESIGN AND LAYOUT HEAO FEET LBS. BASED M.ODEL NO. INCHES HP PHASE RPM CHWP-1 CHILLEO WATER LOOP WAlER 87.2 45.0 57 IN-UNE "3.875 3.0 208/3 3,450 75 B & G SERIES 90, 2AA ~QTE~: 1. INCLUDE BUILT-IN OVERLOAD PR01EC110N, DISCONNECT S\\1TCH AND MOTOR STARTER. 2. PRI~DE HIGH EFRCIENCY MOIDR. DIAPHRAGM TYPE EXPANSION TANK SCHEDULE APPROXIMA1E SYSlEM TEMP. INI]Al MINIMUM MINIMUM PIPE SYSlEM RANGE ('F) PRESSURE IN A.S.M.E. PRESSURE MINIMUM ACCEPTANCE SIZE TO OPERA liNG BELL & GOSSm TAG SYSTEM VOLUME TANK FOR TANK TANK VOLUME VOLUME TANK WEIGHT MODEL NO. (GAL) MIN. MAX. (PSIG) (PSIG) (GAL) (GAL) (INCHES) (LB.) . ET-1 CHIUED WATER 70 40 60 12.8 40 10.9 2.5 112 150 D-15 VAV AIR TERMINAL UNIT SCHEDULE MAX. NC CFM RANGE A.P.D. II ELECTRIC HEAllNG COIL BASIC UNIT DIMENSIONS (INCHES) TAG SER~CE AT 1.25" DESIGN MIN. COOUNG VOLlS/ INLET S.P. UNIT AIRFLOW MIN. EAT MIN. CAP. DISCHARGE COOUNG COOUNG UNIT UNIT UNIT KW STAGES MCA MOCP PHASE INLET I\EIGHT DIS. RAD, AIRFLOW AIRFLOW IN W.C. CFM ('F) (MBH) AT 60HZ SIZE LENGlH WIOlH HEIGHT L8S TU-1 JUDGE'S OFFICE 22 25 550 170 0.04 210 55.0 1D.2 3.0 2 1D.4 15.0 208/3 B"• 10.0" X 11.0' 43.5 17.0 11.5 40 TU-2 CHBF DEPUTY CLERK 19 30 980 295 O.D3 370 55.0 17.1 5.0 3 17.4 ·. 20.0 20B/3 10"¢ 12.o" X 14.Q" 43.5 20.0 13.5 50 TU-3 ALE/STORAGE ROOM 22 25 530 170 0.04 210 55.0 8.5 2.5 2 B.7 15.0 20B/3 B"• 1o.o• x n.o• 43.5 17.D 11.5 40 TU-4 TELE/DATA ROOM 23 29 760 230 O.OB 23D 55.D 6.8 2.0 2 6.9 15.0 20B/3 B"• 10.0" X 11.0" 43.5 17.0 11.5 40 TU-5 WORK STAliONS 21 32 1,120 335 0.04 335 55.0 15.4 4.5 2 15.6 20.0 20B/3 10'¢ 12.Q" X 14.0" 43.5 20.0 . 13.5 50 TU-6 BAIUFF, LOBBY 21 27 1,23D 370 0.03 480 55.0 1B.8 5.5 2 19.1 20.0 20B/3 12'¢ 14.Q" X 17.Q" 43.5 23.0 15.5 60 lU-7 JURY/CONFERENCE ROOM 21 23 430 13D D.03 210 55.0 6.B 2.0 2 6.9 15.0 208/3 B"• 10.0" X 11.o" 43.5 17.0 11.5 40 lU-B LOBBY 15 24 1,280 365 D.03 480 55.0 22.2 6.5 2 22.6 25.0 208/3 12'¢ 14.0' X 17.0" 43.5 23.0 15.5 60 TU-9 COURTROOM - 50U1H 27 3B 1,860 570 0.01 650 55.D 27.3 8.0 3 27.8 30.0 208/3 14'¢ 18.0" X 19.0" 43.5 25.0 19.5 60 TU-10 COURTROOM - NORlH 27 36 1,660 570 0.01 650 55.D 27.3 8.0 3 27.8 30.0 20BI3 14"¢ 18.0' X 19.0" 43.5 25.0 19.5 60 TU-11 PROSECUTOR'S OFFICE 15 21 600 180 0.05 210 55.0 10.3 3.0 2 1D.4 15.0 208/3 a·• 10.0' X 11.0' 43.5 17.0 11.5 40 timES;_ 1. PROV.OE FACTORY MOUNTED DOC CONTROLUERS AND HOT WATER HEAliNG SECliONS, BALANCING DAMPERS AND TRANSFORMERS. 3. DESIGN AND LAYOUT BASED UPCN TRANE CO. SINGLE DUCT AIR TERMNAL UNIT MODEL VCEF. 2. All VAV TERMNALS \\1lll HEAT SHALL BE CONRG\)REO FOR COOUNG I HEAliNG I AUTO CHANGE-OVER. 4. PROVIDE 1' lHICK CLOSED CELL UNIT INSULATION. ELECTRIC UNIT HEATER SCHEDULE AIRFLOW ENT. HEAliNG MAX. ELECTRICAL TAG NO. LOCAliON (CFM) TEMP CAPACITY INPUT VOL lSI ('F) (MBH) (KW) PHASE MCA EUH-1 MECHANICAL ROOM 400 . 45.0 11.2 3.3 208/1 15.9 NOlES: 1. DESIGN BASED ON TRANE MODEL UHEC \\11H BUILT-IN THERMOSTAT, DICONNECT AND SINGLE POINT OF POWER CONNECliON AS REQUIRED FOR COMPLEn: INSTALLAliON. 2. \\1lll MOUNTING BRACKET FOR HORIZONTAL DISCHARGE. . ! NOlES 1,2,3,4,5 N01ES 1,2 NOlES NOlES 1-4 1-4 1-4 1 4 1-4 1 4 1 4 1-4 1-4 1-4 1-4 NOlES 1,2 LLI q: ~ Cl z 0 Cii ~ a: ci z i<-c G ~ i Is~ ':8 iij::f : l: ~ Iii i '1' i!f ~if~ i!f'i - 0 > <(. J: I .. en w ....1 c w ::;) J: 0 en DATE: DRAWN: CJ)(!' ><W.CZ <.c .J 1-. :::- > w .. m ~I- 0~ D..Q <((.) ...J...J u..<C >oS: 1-_::-:(z > .- ) (.)~ 05-09·08 JAE DESIGNED: SGA CHECKED: FCC PROJ. NO. 02-1139-01 SHEET: M101 AlE NAME: 021139M101.DWG ' m ARE DAMPER or FLOOR DRAIN ~ T\'P T\'PICAL 1---HWS---1 FLA FUll LOAD AMPS UH UNIT HEATER 1---HWR- -1 FPM FEET PER MINUTE VAV VARIABLE AIR VOWME I--CD GPM GALLONS PER MINUTE VFD VARIABLE FREQUEINGY DRIVE !r--CW HP HORSEPOWER VSD VARIABLE SPEED DRM: < ' ijJ I HVAC HEAliNG VENliLATION AND AIR I ~G I CONDITIONING VlR VENT THROUGH ROOF HWCP HOT WAlER CIRCULATING PUMP WB WET BUlB HWP HOT WAlER PUMP NOTE: NOT ALL Of THE SYMBOLS AND ABBREVIATIONS ON THIS SHEET ARE NECESSARILY USED IN THIS PROJECT. HVAC LEGEND DESCRIPTION SYMBOL NEW OR RELOCAlED MECHANICAL I £><l I EQUIPMENT I N - I EXISTING MECHANICAL EQUIPMENT 1D BE REMOVED OR RELOCAlED I l<!i\ . ' • SUPPLY DUCT {UP OR DOWN) I--III I RETURN/EXHAUST DUCT {UP OR I I~ DOWN) NEW OR RELOCA1ED CEIUNG MOUN1ED !'f SUPPLY AIR DIFFUSER I ~w I EXISTING CEIUNG MOUN1ED SUPPLY AIR DIFFUSER TO REMAIN ~~ .. I EXISTING DIFFUSER CEIUNG TO BE REMOVED MOUNlED SUPPLY AIR I .. I NEW OR RELOCA lED CEILING MOUNTED I 18 RETURN AIR GRILLE OR REGISlER 1---+0 EXISliNG CEIUNG MOUNlED RETURN AIR GRILLE OR REGISlER TO REMAIN ~ EXISliNG GRILLE OR CEIUNG REGISlER MOUNlED TO BE RETURN REMOVED AIR ' ' .. , "0 ' ' STANDARD RADIUS ElBOW < ' 0 I RECTANGULAR DUCT - INSIDE I @ I DIMENSIONS, ARST AGURE IS SIDE CONICAL SHOWN BRANCH TAKE-OFF '" 1-- CHWS ---1 ROUND DUCT (AGURE=SIZE) 1-- CHWR ---1 OVAL DUCT {AGURE=SIZE) I X ' ' 45' CONICAL ROUND TAKE-OFF TURNING VANES 1\llll ElBOW AIR DE\1CE DESIGNA liON AND FLOW MANUAL VOLUME DAMPER (~TH LOCKING QUADRANT) NEW OR RELOCAlED DUCTWORK EXISTING OUClWORK TO REMAIN EXISTING DUClWORK TO BE REMOVED ARE DAMPER COMBINATION ARE/SMOKE DAMPER SLOT CEIUNG DIFFUSER FLEXIBLE DUCT THERMOSTAT- COOUNG AND HEAliNG ~TH LOCKING COVER (AGURE: UNIT SERVED NUMBER.) CARBON MONOXIDE SENSOR (UNIT) POINT OF NEW CONNECTION NOTE BY SYMBOL {NUMBER REFERENCE AS MARKED) CAP ON EXISTING DUCTWORK OR PiPE HOT WAlER SUPPLY (HWS) HOT WATER RETURN (HWR) CONDENSAlE DRAIN PIPING DOMESTIC COLD WATER PIPING BUTTERFLY VALVE GAS PRESSURE REGULATOR DESCRIPTION GATE VALVE CHECK VALVE BALL VALVE UNION OR FLANGE VALVE IN RISER SAFETY REUEF VALVE WAlER PRESSURE REDUCING VALVE DIRECTION OF PIPE PITCH (DOWN) DIRECTION Of FLOW ELBOW DOWN ElBOW UP PIPE CAIP SlRAINER (PR0\1DE GATE VALVE AND HOSE CONNECTION) TWD-WAY MODULATING CONlROL VALVE BALANCING VALVE SPRINKUER HEAD CHILLED WATER SUPPLY CHILLED WA1ER RETURN PIPE ANCHORS OR HEAT lRACE ,, GENERAL NOTES NOlE DESCRIPTION A. ALL WORK SHAll BE IN ACCORDANCE ~TH THE CITY OF LA PORTE BJJILDING, PLUMBING, ARE PROTECTION, AND MECHANICAL CODES AND \11TH ALL STAlE AND NATIONAL CODES AS THEY MAY AIPPLY TO THE PROJECT AND TO PUBUC SAFETY. B. SHOULD DISCREPANCIES OCCUR 1\lTHIN THE CONlRACT DOCUMENTS, THE MORE SlRINGENT AND MORE COSJLY APPROACH SHAll APPLY FOR BIDDING PURPOSES. THE CONlRACTOR IS TO NOTIFY THE OWNER'S REPRESENTATIVE Of DISCREPANCIES FOR CLARIFICAliON. CLARIFICAliONS ISSUED AF1ER THE CONlRACT IS AWARDED ARE TO BE INCORPORAlED BY THE CONlRAC!DR AT NO ADDITIONAL COSTS AND ARE TO BE REVIEWED BY THE OWNER'S REPRESENTATIVE TO DElERMINE IF A REDUCTION IN COST IS JUSliAED. C. THE CONlRACTOR SHALL OBTAIN ALL PERMITS AND PAY ALL FEES AND CHARGES TO ALL LOCAL AND OTHER RELATED AGENCIES AS REQUIRED. D. PR0\1DE All MATERIALS, LABOR, EQUIPMENT, AND SERVICES NECESSARY FOR A COMPLETE AND OPERABLE INSTALLATION AS SPECIAED AND SHOWN ON THE DRA\\lNGS, FULLY TESTED, ADJUSTED AND READY FOR USE. E. THE ORA~NGS SHOW THE EXTENT OF THE WORK AND THE GENERAL ARRANGEMENT. THE DRA\\lNGS, HOWEVER, ARE DIAGRAMMATIC AND EXACT COGRDJNAlED LAYOUT OF THE VARIOUS SYsTEMS IS THE RESPONSIBIUTY Of THE CONlRAC!DR. F. VERIFY ANY AND ALL INDICATED CONAGURAliONS, DIMENSIONS AND ELEVATIONS BY AELD MEASUREMENTS AND COORDINATE ~TH ARCHITECTURAL DRA\\lNGS AND SlRUCTURAL CONDiliONS. G. COORDINATE THE CUTTING AND PATCHING OF BUILDING COMPONENTS TO ACCOMMODATE THE INSTALLATION OF THE VARIOUS SYSTEM EQUIPMENT AND MATERIALS. NO SlRUCTURAL MEMBERS SHAll BE CUT 1\lTHOUT PRIOR APPROVAL OF SlRUCTURAL ENGINEER. H. COORDINATE THE INSTALLATION OF THE VARIOUS SYSTEM MAlERIALS AND EQUIPMENT ABOVE CEIUNGS \11TH SUSPENSION SYSTEM, UGHT AXTURES, AND OTHER INSTALLATIONS. I. K. All MATERIALS, EQJJJPMENT AND APPARAlUS INSTALLED ON THE PROJECT SHALL BE NEW AND INSTALLED IN SlRICT ACCORDANCE \11TH THE MANUFACTURER'S PRINTED INSTRUCTIONS. THE MANUFACTURER, OR HIS AUTHORIZED REPRESENT A liVE, SHALL CERTIFY, IN WRITING, TO liiE OWNER AND THE OWNER'S REPRESENTATIVE, THAT THE INSTALLATION HAS BEEN MADE IN ACCGRIDANCE \11TH SUCH PRINlED REQJJJREMENTS. MANUFACTURER'S NAME AND MODEL NUMBERS INDICATED ON THE DRA~NGS ARE ONLY FOR REFERENCE CONVENIENCE. ENGINEER-APPROVED SUBSliTUliONS ARE PERMITlED. THE CONlRACTOR, JHROUGH THE MANUFACTURER. SHALL BE RESPONSIBLE TO CON~RM THE CORRECTNESS OF ALL MODEL NUM3ERS SC AS TO MEET THE SPECIAC PROJECT REQUIREMENTS AND MINIMUM INDICAlED PERFORMANCE. INSTALL EQUIPMENT, MATERIALS AND PIPING SYSTEMS 1D PR0\1DE REQUIRED ACCESS FOR SERVICING, MAINTENANCE, AND GENERAL INSPECTION, PER MANUFACTURER'S INSTRUCTIONS AND LOCAL COGE REQUIREMENTS. COORDINATE THE ~NAL LOCATION OF CONCEALED EQJJIPMEN1 AND DEVICES REQUIRING ACCESS ~TH ANAL LOCATION OF REDUIRED ACCESS PANELS ANO DOORS. ALLOW AMPLE SPACE FOR REMOVAL OF All PARTS THAT REQUIRE REPLACEMENT OR SER\1CING. PIPING SYsTEMS SHAll NOT BLOCK SERI1CE ACCESS OF ANY NAlURE, SUCH AS ALlER REMOVAL, EQUIPMENT ACCESS PANELS, CLEANING OF TUBES, AND SIMILAR 11EMS. L COORDINATE THE EXACT LOCATION OF THIS WORK \11TH THE WORK OF THE OTHER lRADES PRIOR TO FABRICAliON OR INSTALLATION OF SAME •. VERIFY ALL DIMENSIONS AND ELEVATIONS. PR0\1DE ADDiliONAL OFFSETS AND SECTIONS OF MATERIAL AS MAY BE REQUIRED TO MEIET THE APPUCABLE JOB CONDiliON REQUIREMENTS. M. IT 1\lll BE THE RESPONSIBIUTY Of EACH CONlRACTOR TO COOROINA1E BE1\\£EN HIS EQUIPMENT SUPPUERS AND ANY SUBCONlRACTOR AS TO WHICH DEVICES ARE SUPPUED \11TH EQUIPMENT, REQUIRED 1\lRING AND VOLTAGES AND OTHER COORDINATION ITEMS AS RELAlED TO A PROPER AND OPERABLE INSTALLATION. ALL POWER ~RING AND CONlROL \\lRING SHAll COMPLY \11TH DII'ISION 16 REQUIREMENTS. N. CONSlRUCT DUCTS OF COMMERCIAL GALVANIZED STEE~ UNLESS OTHER\\1SE SPECIAED. FABRJCAliON OF DUCTWORK SYSTEMS SHAll CONFORM TO RECOMMENDATIONS AND STANDARDS OF ASHRAE AND SMACNA 1995 EDITION FOR THE PARTICULAR SYSTEM DESIGNED. o. RECTANGULAR, OVAL, AND ROUND SYSTEM DUCTWORK SUPPLYING AIR FROM THE AIR-HANDUNG UNIT TO THE INLET Of THE VAV BOXES SHALL MEET SMACNA CONSlRUCliDN STANDARDS FOR SYSTEMS OPERATING AT PRESSURES Of UP TO 3" OF WAlER GAUGE. DUCTWORK DOWNSlREAM OF VAV-BOKES SHAll BE CONS1RUC1ED FOR OPERATING PRESSURE Of 1" Of WAlER GAUGE P. UNLESS INDICA TEO OTHER\\lSE, All COOLED AND HEATED AIR SUPPLY, RETURN AND OUTSIDE AIR INTAKE DUCTWORK AND PLENUMS SHALL BE INSULATED OR UNED PER SPECIACAliONS Q. DIMENSIONAL LOCATIONS INCLUDING ELEVATIONS INDICATED ON THE DRAI\1NGS ARE APPROXIMATE AND FOR REfERENCE ONLY. THE CONlRACTOR SHALL COORDINA1E 1\llH OTHER UliUliES TO AVOID INlERFERENCES ROUTING DUClWORK AND PIPING. R. SMOKE DETECTOR(S) SHALL BE PR0\1DED BY DMSION 16 IN AIR-CONDiliONING UNITS SUPPL"!1NG GREAlER THAN 2,0DO CFM. DETECTOR SHAll AUTOMATICALLY STOP THEIR RESPECTIVE FAN UPON DETECTING OF SMOKE IN THE MAIN SUPPLY DUCT SERVED BY THAT UNIT. S. THE NEW SYSTEMS SHAll COMPLY \11TH THE REQUIREMENTS Of THE INTERNATIONAL ENERGY CONSERVATION CODE (2003) USTED 1\lTHIN THE MECHANICAL COMPUANCE CER11ACA1E. SUPPLEMENT TO THE CONlRACT DOCUMENTS. I ' ~ it I !I II 'I I " " z 0 (ij 5 LLI 0:: d z I~ ~ I~§ i th c it:ts.: r I~ §II -dj ~ ~ZJ (.) > <J: ( I (/) Cl)(!) 1- w <CZ 0 a: .<z ..1 ( 1-xc w:... ::::m :d > w W· (z w !). .. 1-a: t- a: a 0:::> z <( D..Q a <((.) w z ....I_J (w !) u.< 0 .1- (- z ./.1 ) - o!>t-_::-:z (b > - .) -> <( (.)~ a: w m m <(