Loading...
HomeMy WebLinkAboutO-1987-1569 e . ORDINANCE NO. 1569 AN ORDINANCE AMENDING CHAPTER 22-1/2 OF THE CODE OF ORDINANCES OF THE CITY OF LA PORTE, BY ADOPTING THE NEW AND MOST RECENT EDITION OF THE STANDARD SWIMMING POOL CODE, 1985 EDITION, AND APPENDICES, BY AMENDING TERMS UNDER WHICH THE STANDARD SWIMMING POOL CODE IS TO BE ADOPTED BY THE CITY BY ALTERING THE MECHANICAL REQUIREMENTS; PROVIDING THAT ANY PERSON VIOLATING THE TERMS OF THIS ORDINANCE SHALL BE DEEMED GUILTY OF A MISDEMEANOR ANO UPON CONVICTION SHALL BE FINED IN ANY SUM NOT MORE THAN TWO HUNDRED DOLLARS ($200.00); CONTAINING A REPEALING CLAUSE; CONTAINING A SEVERABILITY CLAUSE; FINDING COMPLIANCE WITH THE OPEN MEETINGS LAW; AND PROVIDING AN EFFECTIVE DATE HEREOF. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF LA PORTE: Section 1. Section 22-1/2 of the Code of Ordinances of the City of La Porte is hereby amended, to hereafter read as fOllows, to-wit: "Section 22-1/2 0). Adopted The Standard Swimming Pool Code, 1985 Edition, and appendices, as adopted by the Southern Building Code Congress International, is hereby adopted. Provided that the Exception shown in Section 304.2 (Required Equipment) is hereby deleted from said adopted code. A copy of said code is on file in the office of the City Secretary of the City of La Porte, Harris County, T~xas, and is designa~ed as the Swi~ing Pool Code of the City of La Porte, incorporated by reference in this article, and made a part hereof, as fully as if copied at length herein." Section 2. If any section, sentence, phrase, Clause, or any part of any section,. sentence, phrase, or clause, of this ordinance shall, for any reason, be held invalid,. such invalidity shall not affect the remaining portions of the Ordinance, and it is hereby declared to be the intention of this City Council to have passed each section, sentence, phrase or clause, or part thereof, irrespective of the fact that any other section, sentence, phrase or clause, or part thereof, may be declared invalid. Section 3. Any person, as defined in Section 1.02 (27), Texas Penal Code, who shall violate any provision of this ordinance, shall be deemed guilty of a miSdemeanor and upon conviction shall be punished by a fine not to exceed TWO HUNDRED DOLLARS ($200.00). Each day any violation of this ordinance shall continue shall constitute a separate viOlation. Section 4. The City Council officially finds, determines, recites and declares that a sufficient written notice of the date, hour, place and subject of this meeting of the City Council was posted at a place convenient to the public at the City Hall of the city for the time required by law preceding this meeting, as required by the Open Meetings Law, ARticle 6252- 17, Texas Revised Civil Statutes Annotated; and that this meeting has been open to the public as required by law at all times during which this Or- dinance and the subject matter thereof has been discussed, considered and formally acted upon. The City Council further ratifies, approves and confirms such written notice and the contents and posting thereof. T / . . Ordinance No. l569 , Page 2 Section 5., This Ordinance shall be effective fourteen its passage and approval. The City Secretary shall give passage of this ordinance by causing the caption hereof to the official newspaper in the City of La Porte at least twice days after the passage.of this ordinance. (14) days after notice of the be published in within ten (0) PASSED AND APPROVED THIS THE ~ DAY OF Nnu-FomhAr , 1987. CITY OF LA PORTE By: ATTEST: (I~~ CHERIE BLACK, City Secretary BY.~4~ . N MALONE, ayo APPROVED: ,-ER 3 :QUIREMENTS Standards for Public Swimming Pools", dated April I, 1m published by the National Swimming Pool Institute or other accepted engineering practices and shall be of such character as to secure the results sougbl to be obtained by this Code. \304;2-REOOIREO.EQUIPMENT Every swunming pool shan-be-<<tuipped-cO~plete- -With .approWiInrechaniGat-/ e4uipment consisting ~f!~te~l?~~J~!ping valves and .c9mponent parts: <:;:_j L-:-~CEPTION: Pools with a supply of fresh water equivalent f6'- D6t....ertr ~ vplume of the P-QQI in..the..specifu:d.tumover-time.,wLbe..alJowedJ , . 304.3-WATER VELOCITY Pool piping shall be designed so the water velocity ~ill not ex~d 10 ftl see, except that the water velocity shall not exaled 8 ft/see m copper tubmg. EXCEPTION: Jet inlet fittings shall not be deemed subject to this requirement. "EAAL !e, all piping, equipment and mate- conform to the Standard Plumbing o swimming pools that are built in IOVALS :nt or appliances entering into the .15 thereof shall be of a type complying Ided and approved by a nationally ) other recognized standards acceptable these requirements, the Administrative uire that all equipment, materials, :atures shall be proven to function essive maintenance and operational 304.4-PIPING TO HEATER When approved plastic pipe is used for pool piping, 10 ft of approved metal piping shall be installed on the down-stream side of any water heating equipment, and a check valve shall be installed adjacent to heating equipment on the up-stream side prior to the connection of plastic pipe, EXCEPTION: For rapid or hi-rate sand filters, check valve may be excluded. plicant to provide such data, tests, material or product will satisfactorily ntended, before such item shall be 304.5-PIPING INSTALLATION All piping materials shall be installed in strict accordance with the manufacturer's installation standards, 305-PUMPS JALS AND METHODS UCTION "ION Itended to prevent the use of any n, appliance or equipment provided lved and its use authorized by the 305.1-STRAINER Pool circulating pumps shall be equipped on the inlet side with an approved type hair and lint strainer when used with a pressure ruter, 3OS.2-MOUNTING Pumps shall be mounted on a substantial base in a manner that will eliminate strain on piping. substantiate claims for alternates, lire tests, as proof of compliance, pense of the applicant. 305,3-CAPACITY Pumps shall have design capacity at the following heads. I. Pressure Diatomaceous Earth-At least 60 ft. 2. Vacuum Diatomaceous Earth-20 in vacuum on the suction side and 40 ft total head, 3. Rapid Sand-At least 45 ft. A. High Rate Sand-At least 60 ft. NG DESIGN hall be in confonnity with "Minimum Standard SwimminG Pool CodeI1985 Standard Swimming Pool Code/1985 11