Laserfiche WebLink
<br />'_ <br /> <br />RATINGS <br /> <br />_ <br /> <br />_ <br /> <br />- <br /> <br />RESISTANCE <br /> <br />FIRE RESISTANCE <br /> <br />RATINGS <br /> <br />FIRE <br /> <br />COL UMN PROTECTIONS-Continued <br />Based on Standard Fire <br /> <br />WALLS AND PARTITIONS-Continued <br /> <br />Tests <br /> <br />Ratings <br /> <br />Resistance <br /> <br />Fire <br /> <br />. <br /> <br />It <br /> <br />Tests <br /> <br />Based on Standard Fire <br /> <br />Ratings <br /> <br />Fire Resistance <br /> <br />~, <br /> <br />Rating <br /> <br />Protection <br /> <br />1~ in. U.L. listed L-shaped precast concrete units <br />secured to flange of column and metal edge of adjacent <br />unit by steel studs welded in place. Vertical and Hori- <br />zontal joints filled with a 3:1 mix (by volume) of <br />perlite and cement mortar. Fill of 8:1 mix (by vol- <br />ume) of perlite and cement. Other details as specified <br />in U.L. Iistingc, under Column Protection-Design <br />No. 5-4 HR <br /> <br />of <br /> <br />Details <br /> <br />Type <br /> <br />Steel <br />Columns <br /> <br />;', <br />f. <br /> <br />Rating <br /> <br />Construction <br /> <br />~ in. 1 :2, 1:2 gypsum and sand plaster on ~ in. <br />plain gypsum lath attached by nails fitted with 1~ <br />x 1~ in. metal lath pads folded over heads, spaced <br />8 in. vertically, 16 in. horizontally. (7, 9)"... <br /> <br />of <br /> <br />Details <br /> <br />hr. <br /> <br />1 <br /> <br />~ in. 4:1 gypsum and sand plaster on ~ in. plain <br />gypsum lath; 3 in. strips of metal lath over all <br />joints. (8) <br /> <br />Type <br /> <br />Wood Stud <br />Partitions, <br />Plastered <br />Studs 2 x 4 <br />in. or larger. <br />Finished <br />each side <br />as noted <br /> <br />4 hrs. <br /> <br />hr. <br /> <br />1 <br /> <br />2~ in. gypsum-perlite plaster reinforced with poultry <br />netting, on ~ in. gypsum lath boxed around column. <br />Plaster mix: scratch coat 3~ cu. ft. and brown coat <br />4 cu. ft. U.L. listed perlite plaster aggregate to 100 lb. <br />unfibered gypsum. No fill. Other details as specified <br />in U.L. listingc,under Column Protection-Design No. <br />4-4 HR . <br /> <br />hr. <br /> <br />1 <br /> <br />on metal <br /> <br />sand plaster <br /> <br />and <br /> <br />gypsum <br /> <br />1 :2, 1:3 <br />(7, 9) <br /> <br />~ in. <br />lath. <br /> <br />hr. <br /> <br />1 <br /> <br />metal <br /> <br />on <br /> <br />sand plaster <br /> <br />and <br /> <br />gypsum <br /> <br />~ in. 1:2, 1:2 <br />lath. (7, 9) <br /> <br />4 hrs. <br /> <br />~ in. 1:2 gypsum and sand plaster on U.L. listed <br />wire lath (paper-backed fabric) as specified in <br />U.L. listingc, under Walls and Partitions-Design <br />No. 1-1 HR. <br /> <br />4 hrs, <br /> <br />4 hrs. <br /> <br />4 hrs. <br /> <br />1~ in. (measured from face of lath) gypsum-perlite <br />plaster on metal lath spaced 1 ~ in. from column with <br />plaster pushed through to column flanges. Plaster <br />mix: scratch coat 2 cu. ft. and brown coat 3 cu. ft. <br />U.L. listed perlite plaster aggregate to 100 lb. fibered <br />gypsum. No fill. Other details as specified in U.L. <br />Iistingc, under Column Protection-Design No. 2-4 <br />HR. <br /> <br />2 in. portland cement vermiculite plaster reinforced with <br />plain wire fabric, on paperbacked No. 16 gauge welded <br />wire fabric. Plaster mix: 4 cu. ft. U.L. listed vermicu- <br />lite plaster aggregate to 94 lbs. of portland cement. <br />No fill. Other details as specified in U.L. listingc, <br />under Column Protection-Design No; 10-4 HR......... <br /> <br />in. gypsum-vermiculite plaster (measured from face <br />of lath) on metal lath spaced 1 in. from column. <br />Plaster mix: 4:1 by weight or approx. 100 lbs. <br />fibered gypsum to 2~ cu. ft. vermiculite. Loose ver- <br />miculite fill. (32) <br /> <br />~ in. (measured from face of lath) gypsum vermicu- <br />lite plaster on self-furring metal lath. Plaster mix: <br />scratch coat 2 cu. ft. and brown coat 3 cu. ft. U.L. <br />listed vermiculite plaster aggregate to 100 lbs. fibered <br />gypsum. No fill. Other details as specified in U.L. <br />Iistingc, under Column Protection-Design No. 9-4 <br />HR. <br /> <br />hr <br /> <br />9/16 in. gypsum-perlite plaster on ~ in. perforated <br />gypsum lath. Plaster mix for scratch and brown <br />coats, 2 to 3 cu. ft. U.L. listed perlite to 100 <br />lbs. fibered gypsum. Other details as specified <br />in U.L. Iistingc, under Walls and Partitions- <br />Design No. 7-1 HR <br /> <br />. <br /> <br />tI <br /> <br />hr. <br /> <br />1 <br /> <br />~ in. gypsum-perlite plaster on ~ in. perforated <br />gypsum lath, securely attached by metal clips. <br />Plaster mix: 2~ cu. ft. perlite to 100 lbs. gypsum. <br />(47) <br /> <br />hr. <br /> <br />1 <br /> <br />~ in. 1 :1/10 :1/30:2 portland cement, lime, asbestos <br />fiber, sand and 1:3 gypsum and sand plaster on <br />metal lath. (7) <br /> <br />hr. <br /> <br />1 <br /> <br />1 :1/30:3 portland cement, asbestos <br />plaster on metal lath. (7, 9) <br /> <br />~ in. 1 :1/30 :2', <br />fiber and sand <br /> <br />,.i\ <br />'I <br /> <br />,/ <br /> <br />~I <br /> <br />hr. <br /> <br />Two layers % in. gypsum wallboardcc. First <br />layer attached with 2 in. cement coated nails, <br />spaced 9 in. on centers; second layer attached with <br />2~ in. cement coated nails spaced 7 in. on centers. <br />Vertical joint between boards on same stud for <br />each layer. Joint to fall on adjacent stud on op- <br />posite side. Joints covered with fiber tape and <br />cement. (86) <br /> <br />Wood Stud <br />Partitions <br />Without <br />Plaster <br />Studs 2 x 4 <br />in. or larger. <br />Finished <br />each side <br />as noted <br /> <br />4 hrs. <br /> <br />3 hrs, <br /> <br />in. gypsum-perlite plaster reinforced with wire mesh, <br />on two layers of ~ in. gypsum lath boxed around <br />column and fastened with wire ties. Plaster mix: <br />100 lbs. gypsum to 2~ cu. ft. perlite. (92) .................. <br /> <br />1~ in. gypsum-perlite plaster reinforced with wire mesh, <br />on ~ in. gypsum lath boxed around column and <br />fastened with wire ties. Plaster mix: lOa lbs. gypsum <br />to 2~ cu. ft. perlite. (92) <br /> <br />2 hrs.bb <br /> <br />Two layers % gypsum wallboardcc. First layer <br />applied vertically with edge joints on the studs and <br />attached with 1~ in. cement coated nails spaced <br />6 in. on centers; second layer applied horizontally <br />with edge joints off the studs and attached with <br />I~ in. cement coated nails spaced 12 in. on centers. <br />All joints and nailheads covered with tape and joint <br />finisher. Other details as specified in U.L. Iistingc, <br />under Walls and Partitions-Design No. 4-2 HR. <br /> <br />3 hrs. <br /> <br />~ in. gypsum-perlite plaster, on two layers of ~ in. <br />gypsum lath boxed around column and fastened with <br />wire ties. Plaster mix: scratch coat 2 cu. ft. and <br />brown coat 3 cu. ft. perlite to 100 lbs. gypsum. (92) <br /> <br />47. <br /> <br />2hrs.bb <br /> <br />3 hrs. <br /> <br />page <br /> <br />to notes, <br /> <br />refer <br />13 <br /> <br />superscripts <br /> <br />Letter <br /> <br />. <br /> <br />It <br /> <br />page 47. <br /> <br />to notes, <br /> <br />Letter superscripts refer <br /> <br />44 <br /> <br />· Nonbearing. <br />