<br />VIII <br /> <br />'.' <br /> <br />il <br /> <br />. <br /> <br />39 <br /> <br />8. <br /> <br />(a). In garages exceeding 600 square feet in area, direct fired <br />heating appliances, other than unit heaters located at least 8 feet <br />above the floor, shaU be located in a room used for no other purpose <br />and cut off from the garage by noncombustible construction having <br />a fire resistance rating of not iess than 3 hours. Opening::; hi the <br />above mentioned cut-offs shall be restricted to those necessary for <br />heating, pipes and ducts. <br /> <br />". <br /> <br />. <br /> <br />'. <br /> <br />Heating. <br /> <br />(b). Walls, floors and ceilings which effect such separation <br />shall be continuous and unpierced by openings of any kind; pro- <br />vided that door openings equipped with self-closing fire doors lead- <br />ing to salesrooms or offices that are operated in connection with <br />such garages shall not be prohibited; and provided also that the <br />use of elevators and stairways to other stories accessible only by <br />vestibules or balconies, constructed and arranged as required for <br />fire towers, shall be permitted. <br /> <br />5. Truck loading or unloading area. A truck loading or un- <br />loading area within a building occupied as a store shall be sepa- <br />rated from other parts of the building by construction having a fire <br />resistance rating of not less than one hour, and any load bearing <br />part of the building within the loading area shall also have a fire <br />resistance rating of not less than one hour. <br /> <br />6. Ramps. Ramps connecting floors of garages, which are not <br />considered as required exit ways under section 15, need not be en- <br />closed in sprinklered garages, nor in open air parking garages. <br /> <br />7. Floors. Garage floors of other than earth construction <br />which drain to sewers or storm drains shall be provided with an <br />oil separator or trap. Where floor areas are extensive, a series of <br />such drains shall be provided. The contents of oil separators or <br />traps shall be collected at frequent intervals and removed from the <br />premises. Floors in repair sections shall be concrete or other ma- <br />terials that may be readily cleaned. <br /> <br />following respects <br /> <br />(1) Section '..__..00___' paragraphs " ....-----... and ."___no, <br />amended as follows: <br />Note.-Amendments deemed necessary should be inserted. <br /> <br />\. ..... ... . . <br />Section 8. Date of Effect. . <br /> <br />This ordinance shall take effect sixty days after its approval as required <br />by.1aw. <br />. N ote.-Only in unusual circumstances should a building code, <br />which affects so many interests, and these so extensively, be made to <br />take effect immediately upon enactment. A fair a\lowance would seem <br />to be sixty days. This should give ample time to complete the develop- <br />ment of plans, the preparation of which was begun before the adoption <br />of the code, and on which considerable money had already been <br />expended. <br /> <br />'I <br /> <br />'. <br /> <br />4. square feet in area. <br /> <br />(a) A garage exceeding 3,000 square feet in area may be lo- <br />cated within or attached to a building occupied for any other pur- <br />pose provided it i~ separated from such other occupancy by masonry <br />walls having a fire resistance rating of not less than 3 hours and <br />by floors and ceilings of fireproof construction or semifireproof <br />construction. <br /> <br />. <br /> <br />. <br /> <br />Garages exceeding 3,000 <br /> <br />3. Garages not exceeding 3,000 square feet in area. A garage <br />not exceeding 3,000 square feet in area may be attached to or form <br />a part of any building provided separation from other occupancies <br />shall be by walls and floor and ceiling constructions of at least one- <br />hour fire resistance, and with all connecting openings provided with <br />self-closing fire doors. Floors shall be without pits or depressions. <br /> <br />Section Amendments <br />The said code is amended and <br /> <br />7. <br /> <br />e. <br />Made in Said Code. <br />changed <br /> <br />in <br /> <br />the <br /> <br />are <br /> <br />e <br /> <br />e <br /> <br />(b). Openings from the bUilg into garage shall be re- <br />stricted to a single doorway; such opening shall be provided with a <br />metal, metal covered or solid wooden door of not less than 1~ inches <br />nominal thickness equipped with an approved self-closing device. <br />(c) Floors shall be without pits or depressions. <br />