Laserfiche WebLink
<br />,e <br /> <br />, <br /> <br />t <br /> <br />" <br /> <br />. <br /> <br />e <br /> <br />-38- <br /> <br />(c) In all other buildings such parapets ,shall be not less than 12 <br />inches thick" and carried not less than 3 feet above the roof. <br />(d) Parapets sha:~l be properly coped with noncombustible, weatherproof <br />:naterial and nashed with the flashing ex tending through the parapet wall under the <br />t~oping. All corners of all parapet walls shall be reinforced with at least one i <br />:Ll'lch round bar in every third joint" continuous around the corner and extending into <br />1ihe masonry at least 3 feet from the corner. <br /> <br />SECTION 31. FIRE PARTITIONS. <br /> <br />1. Construction.. <br />(a) Fire partitions shaJ.l have fire resistance ratings of at least <br />two hours. They sh all be constructed of mas onry or reinforced concrete, or other <br />approved form of constructio::l of noncombustible materials. Fire partitions used <br />for load bearing shall confo::-m to the requirements for bearing walls in sections <br />27 & 28, in addition to meet:ing the requirements of this section. <br />(b) Fire parti tiollS shall b e supported in each story on construction <br />h.9.ving a fire resistance rat:.ng of not less than 2 hours; provided that when they <br />a.].s 0 are load bearing, the supporting construction shall have a fire resistance <br />rating of not less than 4 hOl;rs in case the building is of fireproof construction <br />or semifireproof construction, and not less than 3 hours in case of other con- <br />s1:it"uction. <br /> <br />(c) The maximum lU'lsupported height of a fire partitiop. shall not exceed <br />lE: times its total thiclmess unless suitably reinforced and. anchored at floor and <br /> <br />ceiling or unless substantially secured to vertical supports at int;ervals of not <br />ov'er 18 times the thiclmess. <br />(d) Fire partition:3 shall be deemed continuous, even though the several <br />pa.:rts are not ctir ectly over one another in successive stories if the intervening <br />pa:rts of the floors at the leyels where offsets occur, are unpierced and of fire- <br />pr':>of construction or semifirElproof construction and all parts not supported directly <br />on the foundations are carried on f~reproof construction. <br />2. OPENINGS. <br />(a) Required fire p~rtitions shall have ~o openings other than required <br />dOClr openings, or properly prctected duct openings. <br />(b) Each opening in a required fire partition shall be equipped with an <br />approved fire door set in an approved door frame. <br />(c) Ea.6h opening in a fire partition serving as a horizontal exit shall <br />be protected by an approved self-closing fire door. <br />