Laserfiche WebLink
<br />e' <br /> <br />'~ <br /> <br />'" <br /> <br />.~ <br /> <br />, <br /> <br />,.!!!:" <br /> <br />.' <br /> <br />. <br /> <br />-39- <br /> <br />SECTION 32. PROTl~TI ON OF EXTERIOR OPENnms. <br /> <br />Every bUilcling" e:ccept dwellings, churches" buildings of wood frame <br />I~onstruction and of unprotec:tcd metal construction, and open at r parld.ng garages <br />:shall have approved fire vlindOW's or other approved protectives, in every opening <br />in the exterior vTalls when e:uch opening faces on a street and is less than 30 feet <br /> <br />from the opposite building line, or 'When such opening is less than 30 feet distant <br />jJl a direct unobstructed line from an opening in en other bUilding, or when such <br />opening is above and not more than 30 feet distant from any part of a neighboring <br /> <br />l"oof of combustible construction, or any roof' having openings ,rlthin this distance; <br />provided that 51 ch protectio::J. shall not be required for show windOW's facing on a <br /> <br />street which do not extend a':>ove the first full story above grade; and provided <br />further that such protection shall not be required when the opening to be pro- <br /> <br />tected and the opening againnt vhich it is to be protected are situated in walls <br /> <br />in the same plane or in para.:.1el planes and are facing in the same direction. <br />SECTION 33. SHAFT~:. <br /> <br />1. Protection required. <br />(a) Every series cf openings above one another in two or more success- <br />ive floors or noors and roof, hereafter placed or constructed in a building or <br /> <br />he!I'eafter enlarged or altered to change the use of the shaft, shall be so protected <br /> <br />as to prevent fire in any story from communicating to any other story; provided <br /> <br />that in buildings of heavy timber construction there shall be no floor open:i..ng <br /> <br />that is not protected as pres ::ribed in this section or in some other approved <br /> <br />manner . <br /> <br />(b) The provisions of this section shall apply to all shafts used for <br /> <br />ventilation" light, elevator, pipes, or other purpose; except stairways" air ducts, <br />indnerator flues, shafts in buildings of "ood frame construction, shafts in dwell- <br /> <br />". <br /> <br />ings, and ramps in garages eJCeanpted by Secti on 40-6. <br />2. SH.U'T ENCLQSUR~i. The enclosing walls of shafts in residence build- <br /> <br />ings of ordinary construction or noncombustible construction or unprotected metal <br />construction shaD. have a fire resistance rating of not less than 1 hour. The en... <br />clc1sing VlaJ..lS of shafts in other buildings shall be noncombustible construction having <br />a j:ire resistance rating of not less than 2 hours. <br />3. OPENINGS. Shaft enclosures shall have no openings other than those <br />nec,essary for the purpose of the shaft; provided that in elevator shafts there shall <br />be at least one door in every 30 feet of the height of Slch shaft. Such openings <br />shall be protected with approv3d fire doors, approved fire shutters or approved fire <br /> <br />v1indOll'[s. <br />