My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
O-1954-476
LaPorte
>
.Ordinances
>
1950's
>
1954
>
O-1954-476
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2016 3:38:20 PM
Creation date
10/23/2006 6:14:47 PM
Metadata
Fields
Template:
Legislative Records
Legislative Type
Ordinance
Date
8/20/1954
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />e <br /> <br />t <br /> <br />t <br /> <br />-, <br /> <br />. <br /> <br />-40- <br /> <br />. <br /> <br />4. ENCLOSUHE AT . 'lOP . <br />(a) Shaft enclosurl~s extending through the roof 'Which are to be en- <br />closed at the top, shall be provided with a skylight of at least 10 per cent of <br />the area of the shaft in the "jOP story and glazed with plain glass liB-inch in <br />thickness; provided that the :Jkylightmay be replaced by a window of plain glass <br />of equivalent area in the sidH of the shaft if the sill of such window is not less <br />than 2 feet above the roof and the "dIldOVI' does not f ace a lot line wi thin 10 feet, <br />or may be replaced by approved means of ventilation. <br />(b) A shaft that does not extend through the roof shall have the top <br />enclosed with a form of const!:-uction having a fire resistance rating equal to <br />that of the walls of the shaf"~. <br />5. ENCLOSURE AT BO~rTOM. A shaft that does not extend to the bottom <br />of the building shall be encl.)sed at its lowest point with a floor construction <br />of the same type as that required for the lowest floor to or through which it <br />passes, but such shaft floor t~onstruction shall have a fire resistance rating <br />of not less than one hour. <br />6. ELEVP.Tffi MACHlN:m.y COMPARTMENT. Compartments aontaining machinery <br />for operating elevators shall be separated from the elevator shafts by noncom- <br />bustible construction having .3, fire resistance rating of not less than 2 hours, <br />wi'th door openings equipped w:Lth approved fire doors. <br />7. NUMBER OF Er,E,VK~m S IN SHAFT. Not more than 3 elevators shall be <br />placed hereafter in one shaft. <br />SECTION 34, ROOFING. . <br />(a) Every roof herB~ter placed on a building shall be covered <br />with an B:pproved roofing of b::'ick, concrete, tile, slate, metal, asbestos, pre- <br />pared asphalt asbestos-felt s:1ingles, or of built-up roofine finished with asphalt, <br />slag or gravel, or other appr:>ved material, except that dwellings, private gar'ages, <br />and barns separated by at least twelve feet from other buildings may be roofed with <br />a good grade of wood shingles. <br />(b) Except lmere r:>ofing is of a character permitting atta.chment direct <br />te, frame 'Work, it shall be Bf>:?lied to a solid or closely fitted deck. (c) Roofings which are listed as Class A or B roof covering materials <br />by' Underwriters r Laboratories, Inc., shall be accepted as meeting the requirements <br />of this section. <br />
The URL can be used to link to this page
Your browser does not support the video tag.