Laserfiche WebLink
<br />,.-J-;.. .. <br /> <br />'. <br /> <br />I <br /> <br />, <br /> <br />, <br /> <br />. <br /> <br />. <br /> <br />-43- <br /> <br />(b) Every such chimney hereafter erected' or altered shall be lined <br /> <br />with a flue lining confornrlng to the requirements below. <br />(c) Flue lining::; shall be made of fire clay or other refractory <br />clay 1'J'hich will withstand t.he action of flue gases and resist 'Wi. thout soften- <br /> <br />ing or cracking, the tempel'awes to l'lhich they vd.ll be subjected, but not <br />less than 2,0000 Fahrenhei1" or of cast iron of approved quality, form and <br /> <br />construction. <br /> <br />(d) Required clcY flue linings shall be not less than 518 of an <br /> <br />inch thick for the smaller flues and increasing in thickness for the larger <br /> <br />flues. <br /> <br />(e) Flue lining::: shall be installed ahead of the construction of the <br />chimney as it is carried up, carefully bedded one on the other in Type A, type <br /> <br />B or fire clay mortar with close fitting joints left smooth on the inside. <br /> <br />(f) Flue lining::: shall start from a point net less than 8 inches <br />below the intake, or, in tt,e case of fireplaces, from the throat of the fire- <br />place. They shall extend, as nearly vertically as possible, for the entire <br />height of the chimney and he extended 4 inches above the top or cap of the <br /> <br />chimney. <br /> <br />(g) Cleanouts for f lues or fireplaces shall be equipped 'With cast <br /> <br />iron doors and frames arranged tOI\3main tightly closed when not in use. <br />(h) When tvro or more flues are contained in the same chinney, at <br />least every third flue sha:l be separated by masonry at least 4 inches thick <br /> <br />bonded into the masonry wa.:!.l of the chimney. Where flue linings are not so <br /> <br />separated, the joints of adjacent flue linings shall be staggered at least 7 <br /> <br />inches. <br /> <br />.5. USE 01" FLUES" Chimneys or flues installed for the use of gas <br /> <br />appliances but which are not suitable for solid or liquid fuels, shall be <br />plainly and per~ntly labeled, IITHLS FLUE IS FOR THE USE OF GAS ;mJRNING <br />APPLIANCES ONLY." The lab~l shall be attached at a point near where the vent <br />pipe enters the chinmey, or VIIi th a type B gas vent used in place of a chimney, <br />at a point where the type :3 gas vent enters a 'wall, floor or ceiling. <br /> <br />6. FIREPLACES. <br /> <br />(a) The back and siCl.es of fireplaces hereafter erected shall be of <br /> <br />solid masonry or reinforced concrete, not less than 8 inches in, thic1mess. A <br /> <br />lining of fire brick at le9.st 2 inches thick or other approved material shall be <br />provided unless the thiclmess is 12 inches. <br />