Laserfiche WebLink
<br />fir- }?a77-- t75 <br /> <br />GULLETT & ASSOCIATES, INC. <br /> <br />7705 South Loop East -77012 <br />P.O. Box 230187 -77223 <br />Houston, Texas <br />713-644-3219 <br />Fax: 713-644-1547 <br /> <br />December 3, 2007 <br /> <br />Planning Department <br />Mr. Rodney L. Slaton <br />City of La Porte <br />604 W. Fairmont Parkway <br />La Porte, Texas 77571 <br /> <br />RE: Revised Permit Application package for SOUTH TEXAS NGL PIPELINES, LLC <br />to install a 6" pipeline interconnect system within the city limits of the City of La Porte, <br />Harris County, Texas. <br /> <br />Dear Mr. Slaton: <br /> <br />SOUTH TEXAS NGL PIPELINES, LLC a Delaware limited liability corporation whose <br />address is P.O. Box 4324 Houston, Texas 77210-4324, is hereby requesting a pipeline <br />permit. <br /> <br />The pipeline will be used to transport liquefied petroleum gases (MSDS sheet attached) <br />from an existing pipeline (under construction PT-2007-001)in La Porte. The pipeline then <br />connects to a surface site, exits the surface site and continues on until tying into an <br />existing 6" pipeline south of Union Pacific all in Laporte. The route through the City of <br />LaPorte is shown on the attached map, and described in the permit application form.. <br />Plan and profiles are attached showing city streets in the City of La Porte that will be <br />crossed. <br /> <br />Houston Street <br />Drawing CA-2867-019, Cad File 2867119A-2 <br />Old La Porte Road <br />Drawing CA-2867-018, Cad File 2867118_ <br /> <br />The pipe will be 6.625" outside diameter with a 0.280" wall thickness, and will be API <br />5L X 42 ERW pipe with 15-22 mils thick fusion bond epoxy coating and 25-30 mils aro <br />coating. <br />