Laserfiche WebLink
<br />ORDINANCE N0. 1093-B <br />AN ORDINANCE AMENDING THE 1982 EDITIGN OF THE STANDARD BUILDING CODE, OR <br />CURRENTLY ENFORCED BUILDING CODE, AS AMENDED, AND ALSO KPJOWN AS THE <br />BUILDING CODE OF THE CITY OF LA PORTE; BY APiENDIh1G SECTION 1125, SMOKE <br />DETECTOR SYSTEMS, REQUIRING AND REGULATING SMOKE DETECTORS; PROVIDING A <br />SEVERABILITY CLAUSE; PROVIDING Tt1AT ANY PERSON VIOLATING THE TERt'IS OF <br />THIS ORDINANCE SHALL BE FINED IN HNY SUM NOT MORE THAN TtJO HUNDRED DOLLARS <br />($200.00); CONTAINING A REPEALING CLAUSE; FINDING COh1PLIANCE '~IITH THE <br />OPEN MEETING LA4J; AND PROVIDING AN EFFECTIVE DATE HEREOF., <br />BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF LA PORTE: <br />SECTION 1. Section 1125 of the Standard Building Code, 1982 Edition, <br />or currently enforced building code, heretofore adopted by the City Council <br />of the City of La Porte, be, and the same is hereby amended to read as follows, <br />to-wit: <br />"Section 1125. SMOKE DETECTOR SYSTEMS. Every newly constructed <br />dwelling and every newly constructed dwelling unit within an apartment <br />house, condominium, duplex, townhouse, and every guest room in a hotel, motel, <br />or boarding house, and every base~~nent or cellar within such dwellings sf~all <br />be provided with an Underwriters Laboratories Incorporated rated or Faci:ory <br />Mutual approved smoke detector, which may be~either 120 volt A.C. or battery <br />operated. <br />Care shall be exercised to insure that the installation of all smoke <br />detectors herein required will not interfere with the operating characteris- <br />tics of the detector. <br />Audibility of the alarm. l.~hen activated, all detectors herein required <br />shall provide an audible alarm recognizable as such when sleeping room() <br />door(s) is completely closed." <br />SECTION ~. F~NAI,- APPROVAL <br />1. F1pa1 approval for alb Smoke deteGtQr location(s) herein required <br />for all r!~~I;AC~~ ~x~stin+~ G~nst~uptjon sha~1 b~~the responsibility of thy? <br />Fire Marshalfor his duly authorsz~d representative, <br />~, Final approval and inspection for all smoke detector installation <br />herein`required for all new~an~ exiting construction shall be the responsi- <br />bility Qf the ~h1sf Building Inspector or his duly authorized representative. <br />SECTION 3. LOCATION OF S~10t:E DETECTORS <br />Unless otherwise specified herein, a smoke detector shall be mounted <br />on the ceiling or wall in the hallway(s) giving access to the room(s) used <br />for sleeping purposes The detector shall be located prior to or across from <br />the entrance to the first room inside said hallway(s). If the detector is <br />mounted on the wall, the complete unit shall not be located lower than <br />twelve (12) inches from the ceiling. <br />