My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
1991-07-15 Special Called Meeting and Joint Workshop Meeting
LaPorte
>
City Secretary
>
Minutes
>
City Council
>
1990's
>
1991
>
1991-07-15 Special Called Meeting and Joint Workshop Meeting
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2016 12:07:02 PM
Creation date
3/21/2025 1:47:08 PM
Metadata
Fields
Template:
City Meetings
Meeting Body
City Council
Meeting Doc Type
Minutes
Date
7/15/1991
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />~%,~'E" rhn.F's~fgL ~Et~u'~s I <br />plying with the provisions of this division, comply with the <br />applicable provisions of Divisions 2 and 3 of this article. <br />(b) Class I. Class i flammable liquids ~..".ull be stored in <br />underground storage tanks as per thie article. <br />(c) Class II and III. Class II and III liquids can be stored <br />in either aboveground or underground storage tanks as per this <br />article. <br />(d) Containers of Class I flammable liquids oI' any size -- <br />shall be prohibited within the bulk plant yard or within buildin@:s, <br />aboveground. <br />(e) Containers of combustible liquids stored in buildings <br />when pled one upon the other shall be be separated tc provide <br />stability and to prevent excessive stress on co~~*ainer walls. The <br />height of piles shall be consistent with stability and stren€:th <br />of containers. In no case shall nominal fifty-five (55) gallon <br />drums be stored over three (3) tiers high. <br />Containers of combustible liquids stored in bulk plant yards <br />when piled one upon the other shall be separated to provide stability <br />and to prevent excessive Stress on container walls. The height <br />of ^iles shall be consistent with stability an;: strength of (j <br />containers. In no case shall nominal fifty-five (55) gallon drums <br />be stored over three (3) tiers high, with a tout of drums not <br />to exceed twenty-five (25) for any bulk plant yaro. <br />(f) The outside stora~~e of empty portable tanks and drums pre- <br />viously used for the storage of flar.!mable and combustible liquids <br />shall be in accordance with Section 16.60 and 15.61 of this code. <br />Sec. 16.?.8 Construction of buildings in'which combustible <br />liquids are stored. <br />(a) Buildings shall be constructed ~o that rooms in which <br />combusti~~le liquids are stored. comply with the requirements of <br />the building code. Class II or III combustible liquids <br />shall not be stored or handled within a building having a base- <br />ment or pit. <br />(b) Rooms storing combustible liquids shell have exit.: <br />facilities in accordance with the Building Code of the City of <br />(181) <br />
The URL can be used to link to this page
Your browser does not support the video tag.