<br />'~.J <br /> <br />C. Add prefinished, continuous metal flashing at transition joint from standing seam <br />metal panel at vertical wall surface to sloped panel on canopy. <br />4.5 SHEET A4.02 <br />A. WALL SECTION 01 <br />a. Changed Keyed Note for soffit to 02. <br />b. Change Detail reference 01/A5.03 to Drawing ADD 3.2 <br />B. WALL SECTION 02 <br />a. Change Detail reference 01/A5.03 to Drawing ADD 3.2 <br />b. Add notes to provide prefinished metal cap over icelwatershield undertayment on <br />% inch, exterior grade plywood over steel stud framing members. <br />C. WALL SECTION 03, <br />a. Keyed Note 01 change to 47, and add to Keyed Note column, <br />"Metal wall Panel with standing seam joinf'. <br />b. Change Detail reference 07/A5.03 to 07/A4.04. <br />4.6 SHEET A4.03 <br />A. DETAIL 04, Turn ice/water shield undertayment down over edge of roof behind <br />metal edge trim. <br />B. DETAIL 07, add Keyed Note 22 to face of vertical blocking. <br />4.7 SHEET A4.04 <br />A. SECTIONS 01, 02 AND 03 <br />a. Provide continuous strip of icelwater shield undertayment at top of parapet <br />blocking under metal cap. <br />b. Change metal soffit note to Keyed Note 65 <br />c. Provide continuous prefinished metal trim at exterior edge of metal soffit per <br />Drawing ADD 3.3. <br />B. SECTION 04, Provide continuous strip of icelwater shield undertayment at top of <br />parapet blocking under metal coping. <br />C. SECTION 06 <br />a. Turn icelwater shield undertayment from roof surface down 6 inches minimum <br />on face of wall sheathing. <br />b. Add Keyed notes 03 and 04. <br />D. SECTION 07, add continuous membrane flashing extending from exterior face of <br />Custom cmu and over the top of the custom cmu to the outside face of interior <br />wythe of emu masonry and extending 8 inches up cmu face, <br />E. KEYED NOTES <br />a. Note 28, add "exterior grade" before plywood. <br />b. Add Note 65: Metal Soffit Panel. <br />4.8 SHEET A5.02 <br />A. DETAILS 01,02,04,05,06,08,09,11,12 and 13: Add Keyed Note 26 to outside <br />face of interior cmu in wall cavity to provide dampproofing membrane. <br />B. JAMB DETAIL 12, revise to standard coiling door jamb guide made up of two <br />steel angles 3x3x3/16 and one steel angle 3x2x3/16 in lieu of sectional door <br />guide shown. <br />C. KEYED NOTES, Note 15, add: Transparent Finish. <br /> <br />END OF ADDENDUM NO.3 <br /> <br />Proj. No. 328-1 00900-3 <br />