Laserfiche WebLink
Dangerous Building Inspection Form Page 3 <br />BUILDING EVALUATION CHECKLIST <br />A = Adequate D = Deficient N/A = Not Applicable <br />I. STRUCTURAL. COMMENT / EXPLANATION <br />A. Foundation <br />1. Slab <br />A <br />2. Pier & Beam <br />a. Footings <br />N/A <br />b. Sills <br />N/A <br />c. Joists <br />N/A <br />B. Walls <br />1. Exterior <br />D <br />EXT. WALLS ON ROOM ADDITION HAS ROT & HOLES: MH <br />EXT. SKIN IS ADEQUATE <br />2. Interior <br />D <br />ROT, HOLES IN INT. WAILS OF ADDITION & MH <br />Means of Egress <br />1. Doors <br />a. Interior <br />D <br />MISSING. DAMAGED ON ADDITION & MH <br />b. Exterior <br />A <br />2. Porches, Steps, <br />Mrs <br />D <br />PORCH/STEPS FOR REAR OF MH IS MISSING <br />3. Windows <br />D <br />BROKEN WINDOWS IN ADDITION & MH <br />D. Roof <br />1. Rafters <br />N/A <br />2. Deck, Shingles <br />UNK <br />MH METAL ROOF- UNABLE TO INSPECT, ADDITION ROOF - <br />UNABLE TO INSPECT <br />E. Ceilings <br />1. Joists <br />D <br />ROTTED, DAMAGED ON ADDITION & MH <br />2. Ceiling <br />D <br />MISSING DAMAGED ON MH <br />F. Floors <br />D <br />BUCKLED, HOLES, DAMAGED ON MH <br />G. Other <br />N/A <br />U. MEHCANICAL SYSTEMS <br />A. Electrical <br />1. Service Entance <br />& Pant <br />D <br />NOT TO CODE <br />2. Wiring <br />D <br />NOT TO CODE <br />3. Lights, Switches <br />D <br />MISSING, BROKEN IN MH <br />4. Outlets <br />D <br />MISSING. DAMAGED IN MH <br />5. Other <br />N/A <br />B. Plumbing <br />1. Fixtures <br />a. Sink <br />UNK <br />NO PLBG IN ADDITION: UNABLE TO INSPECT IN MH <br />b. Lavatories <br />UNK <br />NO PLBG IN ADDITION: UNABLE TO INSPECT IN MH <br />c. Water/Closets <br />UNK <br />NO PLBG IN ADDITION: UNABLE TO INSPECT IN MH <br />d. Shower <br />UNK <br />NO PLBG IN ADDITION, UNABLE TO INSPECT IN MH <br />e Water Heater <br />UNK <br />NO PLBG IN ADDITION: UNABLE TO INSPECT IN MH <br />2. Water Piping <br />UNK <br />NO PLBG IN ADDITION: UNABLE TO INSPECT IN MH <br />3. Drain, Waste <br />& Vent <br />UNK <br />NO PLBG IN ADDITION: UNABLE TO INSPECT IN MH <br />4. Sewer/Septic tank <br />D <br />INT. SEWER -UNABLE TO INSPCr: EXT-BROKEN SEWER LINE <br />5. Gas System <br />LINK <br />UNABLE TO INSPECT IN MH <br />C. Heating & A/C <br />1. Heating <br />UNK <br />NO HEATING IN ADDITION,• UNABLE TO INSPECT IN MH <br />2. Air Conditioning <br />UNK <br />NO A/C IN ADDTTION:UNABLE TO INSPECT IN MH <br />III. PROPERTY CONDITIONS <br />1. Accessory Structures N/A <br />2. Condition of Grounds D <br />3. Other D <br />DEBRIS. WEEDS <br />METAL CARPORT- HOLES IN METAL ROOFING <br />Comments: * ROOM ADDITION IS ON SLAB & MOBILE HOME METAL UNDERCARRIAGE HAS BLOCKS ON <br />EXISTING SLAB. MOBILE HOME HAS BEEN DECLARED AS AN ABANDONED NON -CONFORMING <br />STRUCTURE IN AN R-1 ZONE, <br />SACPShare\INSPECTION DIVISIONIAU OTHER STUFF\Code EnforcemeMOang Buildings\D B INSP FORM 210 EDGEWOOD.doc07-2004 Rev. <br />