Laserfiche WebLink
City of La Porte <br />DANGEROUS BUILDING INSPECTION FORM <br />DATE: 7-5-06 <br />STREET ADDRESS: 202 EDGEWOOD <br />HCAD OWNER PAUL BONNER %ELAINE BONNER - P. 0. BOX 913 - LA PORTE, TX 77572-0913 <br />DEED OWNER: PINO CANDELARI & FILOMENA UGUCCIONI — UNKNOWN ADDRESS (LOT 6) <br />DEED OWNER: #2: UNABLE TO LOCATE TITLE DOCUMENT ON LOT 5 [FROM 1953 TO DATEI <br />OTHER: PAUL R BONNER — P.O. BOX 1128 — MONTGOMERY, TX 77356 (SON) <br />LEGAL: BLOCK 2: LOTS 5-6: CRESCENT SHORES <br />OCCUPANCY TYPE: RESIDENCE ZONING: R-1 <br />NON -CONFORMING ISSUES: <br />FACILITIES AVAILABLE: WATER: YES SEWER: YES <br />NO.OF DWELLING UNITS: <br />VACANT: <br />ELECTRICAL: YES GAS: YES <br />OCCUPIED: <br />AS REQUIRED IN THE CITY'S CODE OF ORDINANCE, CHAPTER 82; ARTICLE VIII, THE BOARD OF <br />INSPECTION MADE AN INSPECTION OF THE AFOREIv1ENTIONED PROPERTY, AND DETERMINED THE <br />BUILDING LOCATED THEREON, IN THEIR OPINION, IS IN FACT A DANGEROUS BUILDING, FOR THE <br />FOLLOWING REASONS: <br />Sec. 82-473. Declaration of Public Nuisance and Hazard. <br />A. Dangerous or Substandard Buildings or Structures. <br />A building or structure shall be considered dangerous or substandard whenever it is <br />determined by the Board, that any or all of the following is applicable: <br />4 1. A building that is vacant, and is not up to current building code standards. These vacant buildings <br />can be either open to trespass or boarded up; <br />2. Whenever any portion thereof has been damaged by fire, earthquake, wind, flood, or by any other <br />cause to such an extent that the structural strength or stability thereof is materially less than it was before such <br />catastrophe and is less than the minimum requirements of the building code for new buildings of similar structure, <br />purpose or location; <br />q 3. Whenever any portion or member or appurtenance thereof is likely to fail, or to become detached <br />or dislodged, or to collapse and thereby injure persons or damage property; . <br />4 4. Whenever the building or structure, or any portion thereot because of (a) dilapidation, <br />deterioration, or decay; (b) faulty construction; (c) the removal, movement or instability of any portion of the <br />ground necessary for the purpose of supporting the building; (d) the deterioration, decay, or inadequacy of its <br />foundation, or (e) any other cause, is likely to partially or completely collapse; <br />4 5. Whenever, for any reason, the building or structure, or any portion thereot is manifestly unsafe for <br />the purpose of which it is being used; <br />