<br />and Class C, are defined by the 1985 Life Safety Code (which is the only known <br />source of definition for these categories and there is no specific definition of such <br />categories in the City of La Porte Amendments), then the proposed Family Life <br />Center would fall into the Class C category, i.e., "occupant load greater than 50 <br />but not greater than 300 persons". However, the requirement that a Class C <br />category building have a fire sprinkler system only applies when the building's <br />assembly area is located "two stories or more above the level of exit discharge", <br />i.e., on the third floor or higher. Consequently, since the Family Life Center's <br />assembly area is on the ground floor, a fire sprinkler system would not be <br />required in the building under the City of La Porte Amendments if the specified <br />classification system is applicable to this situation. However, the classification <br />system for assemblies was abolished under the Life Safety Code 1997 so such <br />should not be applicable in the current instance. Likewise, SLI believes it to be <br />clear that an "A-2 small assembly with no stage requiring proscenium opening <br />protection" under the 1994 Standard Building Code does not in any way classify <br />the building as a Class A assembly under the City of La Porte Amendments. <br /> <br />3. <br /> <br />The NFP A 10 I, Life Safety Code 1997 provides that buildings with occupant <br />loads above 300 persons shall be equipped with a fire sprinkler system. However, <br />the Code also provides certain exceptions to this requirement. Specifically, <br />Exception No.2 to this Code provision specifies that a fire sprinkler system will <br />not be required in buildings which have "Assembly occupancies consisting of a <br />single multipurpose room ofless than 12,000 sq. ft...." In the current situation <br />the Family Life Center assembly area and the building itself is less than the <br />stipulated 12,000 s.f. Consequently the Church is not required under this Code <br />provision to install a fire sprinkler system in the building. <br /> <br />-I,,) <br />UJI~ <br />) I 'i.' ,.-( <br /> <br />For the foregoing reasons, on behalf of the First United Methodist Church of La Porte SLI <br />respectfully requests that the City of La Porte Fire Review Board determine that the Church is <br />not required to install a fire sprinkler system in its new Family Life Center. <br /> <br />Thank you for your time in regard to this matter and we look forward to further discussing this <br />issue with you at the upcoming hearing. <br /> <br />Sincerely, <br /> <br />The S.L.I. Group, Inc. <br /> <br />Melissa Centanni <br />Vice President <br />