<br />Sent: Wednesday, February 11, 2004 1:34 PM <br />To: Melissa L. Centanni (melissa@thesligroup.com) <br />Cc: Huber, Mark; Wilmore, Debbie; Christensen, Laurie <br />Subject: 9601 Fairmont 1st United Meth. Church <br /> <br />We have reviewed the 1994 edition of the Standard Building Code as it applies to <br />the information that was provided to us from your office, and determined the <br />following: <br /> <br />The proposed 11,200 square foot expansion of the church would be classified as <br />Small Assembly, Type 4 construction, single story. If this is incorrect or it <br />changes, please let us know. Based upon Table 500 in the building code, the <br />proposed addition would require a fire sprinkler system and a fire alarm system <br />with audible strobes,pulls, and smokes. The one exterior wall closest to the <br />existing walls would need to have a 4 hour rating. If you have further questions <br />or comments J please let me know. <br />