Laserfiche WebLink
<br />~ <br /> <br />e <br /> <br />e' <br /> <br />- <br /> <br />e <br /> <br />il <br />I: <br /> <br />e <br /> <br />e <br /> <br />Ii <br />II <br />jj <br />!I <br />ii SECTIon 22 - APPaOVED METHODS - No oertificate of approval shall be <br />ii issued unless -the inatallation is in s'crict conformity wi;;h the provisions of <br />" this ordinance, the Statutes of the State of Texas, and the rules and rogulation <br />; issued by the Industrial Canmission of the State of Texas under authori;;y of the; <br />is;;ate statutes. I <br />I ' <br />, All joints in or to branch lighting cirouits shall have soldered con- : <br />I: nections. All ceiling outlets in buildings not of conoreto or steel constructio <br />:! shall be provided with a wooden header two inches by four inches lumber seourely <br />!I fastened to studding with the four inch size at rit:;ht angles to the plaoe of the <br />'I light opening. All lighting outlets shall be equipped with 3/8 inch fixture <br />Ii studs except in closets, basements, garages and attic spaces. <br /> <br />-8- <br /> <br />In cold storage vl:l.u1ts, all wiring shall be lead oovered, encased in <br />galvanized oonduit. All lighting equipment shall be of the vapor proof type. <br /> <br />SECTIOlT 23 .. TYPE OF ',iIilmG Ilf CERTAIN STRUCTURES. Knob and tube work <br />;' and non-metal1ic oable shall not be used, exoept that they may be used within i <br />, a building or structure of frame, or frame a:nd veneer,oonstruction, where such l, <br />,\ building or structure is designed far ocoupanoy exclusively as a dwelling for ( <br />I not more than t;wo families, and of not over six circuits, on the servioe or ser- l <br />II' vioes supplying the building or premises to be served; provided, however, that ~. <br />eight circuits will be allowed if all branoh circuits are not smaller than No. " <br />12 \'Tire. ." --~ <br />i <br />I, Surface wooden raoeways, armored type iLC, or concentric wiring syster'1.S <br />it are not approved for use for wiring under alW condition. <br />i <br />I: Open wiring is c:a.pproved only for temporary work, and in central sta- <br />I tions, sub-stations, transformer vaults and at switohboards. E1sev.rhere -than in <br />Ii central stations and sub-stations, all oircuits operating at more than 600 volts <br />~ shall enter buildings or struotures in conduit ron underground. Surface exten- <br />i' sions or installations must have an approved metal enclosur~ and the metal en- <br />il closure shall not be used as one of' the oonductors of the cJ.rcuit. I <br /> <br />'! All sockets within reaoh of persons standing or otherwise touohing the <br />11 earth or grounded surfaces, such as floors or condu'bting material, bathroom, <br />I~ fixtures, kitchen sinks or other grounded surfaces shall be controlled by a wall <br />I! sv.ritch or Viall switohes 'Whioh shall be i\11ly insulated from the operator. <br /> <br />il All wires exp,osed to weather must be weather proof type. <br /> <br />II All serncee and "interior" sub-feeders to distribution panels shall <br />il be installed in rigid galvanized oonduit, except that within six feet of a buildt <br />I',. ing, measured horizontally, from which a sub-feeder originates, will be consid- I <br />' ered "interior", as that term is used in this paragraph. \{here conduit fittings I <br />;, are used ahead of motor cabinet, same shall be sealable type. <br /> <br />I Entrance switohes, except on swithhboard installations, must be of <br />!, externally operatable type, and all distribution cabinets of more than four cir- <br />Ii Quits installations must be ot the dead tront typo vtith vriring spaoe. <br />;! <br /> <br />,.1 All entra.noe switohes and distribution cabinets rated at thirty ampere <br />': or less, are to be equ:i,pped with automatic over current protective devioes so ! <br />Ii designed that the rating of the protective element is definite and cannot readil~ <br />II be changed from one rating to another. I <br /> <br />ii Ylhere miters are installed in inacoessible places in houses or build- ' <br />:i ings and the eleotrio public servioe ccmpa.ny desires to relocate said meter <br />i1loops for oonvenience in the rendering of i1:is service, it may, upon request to <br />the City Eleotrical Inspector, have a master e1eotrician reinstall meter loops <br />to a point 'Where the same \'1ould be located if the house or building VTere having <br />a new system of wiring installed, and all such work so done at tho request of <br />the electric public service company shall be pertorn~thout cost to the owner <br />unless said relocation is the result of said wiring lfeen condemned b~r the <br />City Electrioal Inspector for praotices in violation of the Ordi~nces of the <br />City of La Porte. <br /> <br />~ <br />'I <br />I <br />! <br />