My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
O-2007-1388-D
LaPorte
>
Legislative records
>
GR1000-05 Ordinances - GR1000-05 Ordinances & Resolutions
>
2000's
>
2007
>
O-2007-1388-D
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2016 3:39:21 PM
Creation date
12/11/2014 3:57:00 PM
Metadata
Fields
Template:
Legislative Records
Legislative Type
Ordinance
Date
2/12/2007
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
903.2.2 Group E. <br /> Delete paragraph and substitute with the following: <br /> An automatic sprinkler system must be provided throughout all Group E occupancies.An <br /> automatic.sprinkler system shall also be provided for every portion of educational <br /> buildings below the level of exit discharge. The use of fire walls does not establish a <br /> separate building for purposes of this section. <br /> Exceptions: <br /> 1. Buildings with E occupancies having an occupant load of 49 or less. <br /> 2. Day care uses not otherwise requiring an automatic sprinkler system by other <br /> provisions of the code. <br /> Day care uses that are licensed to care for more than 5 persons between the hours of 10 <br /> p.m. and 6 a.m. shall be equipped with an automatic sprinkler system designed and <br /> installed in accordance with section 903.3.1.3 or an approved equivalent system. This <br /> includes children related to the staff. <br /> 903.2.7 Group R. <br /> Amend this section by adding an exception: <br /> Bed and breakfast occupancies with five rentable sleeping.rooms or less do not require an <br /> automatic suppression system. <br /> 903.2.7.1 Group R-1. <br /> Add new subsection to read as follows: <br /> An Automatic sprinkler system or a residential sprinkler system installed in accordance <br /> with section 903.3.1.2 must be provided throughout all buildings with a group R-1 fire <br /> area. <br /> Exception: Where guest rooms are not more than three stories above the lowest level of <br /> discharge and each guestroom has at least one door leading directly to an exterior exit <br /> access that leads directly to an approved exit. <br />